scholarly journals Heat Transfer Enhancement inside Rectangular Channel by Means of Vortex Generated by Perforated Concave Rectangular Winglets

Fluids ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 43
Author(s):  
Syaiful ◽  
Monica Pranita Hendraswari ◽  
M.S.K. Tony S.U. ◽  
Maria F. Soetanto

Passive methods using vortex generators (VGs) to enhance heat transfer have been a concern of researchers in recent decades. This study is intended to investigate the strength of the vortex generated by VGs by trying to reduce the pressure drop in the flow. The present work also takes into account the influence of the vortex intensity on the improvement of heat transfer, which can be indicated by the low value of the synergy angle. Experiments were carried out in the current investigation to validate the results of the numerical simulations in the Reynolds number range of 3102 to 16,132. The study results indicate that the observed heat transfer coefficients from the experimental and simulation results have a similar tendency with relatively small errors. A reduction in pressure drop is observed with the use of perforated concave rectangular winglets (PCRWs) against the nonperforated ones although there was a slight decrease in heat transfer improvements.

Author(s):  
Sam Ghazi-Hesami ◽  
Dylan Wise ◽  
Keith Taylor ◽  
Peter Ireland ◽  
Étienne Robert

Abstract Turbulators are a promising avenue to enhance heat transfer in a wide variety of applications. An experimental and numerical investigation of heat transfer and pressure drop of a broken V (chevron) turbulator is presented at Reynolds numbers ranging from approximately 300,000 to 900,000 in a rectangular channel with an aspect ratio (width/height) of 1.29. The rib height is 3% of the channel hydraulic diameter while the rib spacing to rib height ratio is fixed at 10. Heat transfer measurements are performed on the flat surface between ribs using transient liquid crystal thermography. The experimental results reveal a significant increase of the heat transfer and friction factor of the ribbed surface compared to a smooth channel. Both parameters increase with Reynolds number, with a heat transfer enhancement ratio of up to 2.15 (relative to a smooth channel) and a friction factor ratio of up to 6.32 over the investigated Reynolds number range. Complementary CFD RANS (Reynolds-Averaged Navier-Stokes) simulations are performed with the κ-ω SST turbulence model in ANSYS Fluent® 17.1, and the numerical estimates are compared against the experimental data. The results reveal that the discrepancy between the experimentally measured area averaged Nusselt number and the numerical estimates increases from approximately 3% to 13% with increasing Reynolds number from 339,000 to 917,000. The numerical estimates indicate turbulators enhance heat transfer by interrupting the boundary layer as well as increasing near surface turbulent kinetic energy and mixing.


1994 ◽  
Vol 116 (4) ◽  
pp. 880-885 ◽  
Author(s):  
St. Tiggelbeck ◽  
N. K. Mitra ◽  
M. Fiebig

Longitudinal vortices can be generated in a channel flow by punching or mounting small triangular or rectangular pieces on the channel wall. Depending on their forms, these vortex generators (VG) are called delta wing, rectangular wing, pair of delta winglets, and pair of rectangular winglets. The heat transfer enhancement and the flow losses incurred by these four basic forms of VGs have been measured and compared in the Reynolds number range of 2000 to 9000 and for angles of attack between 30 and 90 deg. Local heat transfer coefficients on the wall have been measured by liquid crystal thermography. Results show that winglets perform better than wings and a pair of delta winglets can enhance heat transfer by 46 percent at Re=2000 to 120 percent at Re=8000 over the heat transfer on a plate.


2021 ◽  
Vol 8 (3) ◽  
pp. 386-392
Author(s):  
Ahmed Hashim Yousif ◽  
Hakim T. Kadhim ◽  
Kadhim K. Idan Al-Chlaihawi

In this paper, a numerical simulation is performed to study the effect of two types of concave vortex generators (VGs), arranged as fish-tail locomotion in a rectangular channel. The heat transfer and fluid flow characteristics with and without VGs are examined over the Reynolds number range 200≤Re≤2200.The two proposed types of the VGs are selected based on the speed of the fish movement which is arranged in different distances between them (d/H=0.6, 1, 1.3). The results show that the use of VGs can significantly enhance the heat transfer rate, but also increases the friction factor. The heat transfer performance is enhanced by (4-21.1%) reaching the maximum value by using the first type of the VGs at (d/H=1.3) due to better mixing of secondary flow and the new arrangement of the VGs which lead to decreasing the friction factor with an easy flow of fluid.


2001 ◽  
Author(s):  
Srinath V. Ekkad ◽  
Hasan Nasir

Abstract Detailed heat transfer measurements are presented for a rectangular channel with dimples on one wall. Dimpled surfaces provide high heat transfer enhancement comparable to ribbed surfaces with reduced overall pressure drop. The heat transfer coefficients were measured using a transient liquid crystal technique. The effect of channel flow Reynolds number was investigated for a wide range from 10000 to 65000. The channel is a 25.4 mm × 101.6 mm (1” × 4”) rectangular cross-section with the dimples on one of the 101.6 mm wall. Heat transfer enhancement around three times that of a smooth channel were achieved for all flow conditions. The overall pressure drop through the dimpled section of the passage was also measured. The resulting thermal performance of the dimples surfaces is significantly higher compared to channels with protruding ribs.


Author(s):  
M. A. Akhavan-Behabadi ◽  
M. Ghazvini ◽  
E. Rasouli

In this study, the effect of adding nanodiamond powder as an additive to engine oil on laminar flow heat transfer enhancement and pressure drop increasing is experimentally investigated. The plain and microfin tubes were used as the test sections and were heated by an electrical coil heater to produce constant heat fluxes. Thermal conductivity and heat capacity of nanofluids were measured for different volume fractions and temperatures. Convection heat transfer coefficients and Nusselt numbers of nanofluids were obtained for different nanoparticle concentrations as well as various Peclet and Reynolds numbers. Experimental results show the enhancement of heat transfer due to the nanoparticles presence. Furthermore, the effect of particle concentration on pressure drop was studied for different heat fluxes. Finally, the performance evaluation of both nanofluid and microfin tube from the point view of heat transfer enhancement and pressure drop increasing is done.


2007 ◽  
Vol 129 (11) ◽  
pp. 1611-1615 ◽  
Author(s):  
H. S. Ahn ◽  
S. W. Lee ◽  
S. C. Lau

Experiments were conducted to determine the average heat transfer coefficients on three wall segments between blockages with holes in a wide rectangular channel. Eight different configurations of the holes in the blockages—two diameters and four aspect ratios of the holes—were examined. The pressure drops across the blockages were also measured. The results showed that the elongated holes in the blockages in this study enhanced more heat transfer than the round holes, but they also caused larger pressure drops across the blockages.


2013 ◽  
Vol 135 (4) ◽  
Author(s):  
Justin Lamont ◽  
Sridharan Ramesh ◽  
Srinath V. Ekkad ◽  
Anil Tolpadi ◽  
Christopher Kaminski ◽  
...  

Detailed heat transfer coefficient distributions have been obtained for narrow diverging channels with and without enhancement features. The cooling configurations considered include rib turbulators and concavities (or dimples) on the main heat transfer surfaces. All of the measurements are presented at a representative Reynolds number of 28,000. Pressure drop measurements for the overall channel are also presented to evaluate the heat transfer enhancement geometry with respect to the pumping power requirements. The test models were studied for wall heat transfer coefficient measurements using the transient liquid crystal technique. The model wall inner surfaces were sprayed with thermochromic liquid crystals and a transient test was used to obtain the local heat transfer coefficients from the measured color change. An analysis of the results shows that the choice of designs is limited by the available pressure drop, even if the design provides significantly higher heat transfer coefficients. Dimpled surfaces provide appreciably high heat transfer coefficients and a reasonable pressure drop, whereas ribbed ducts provide significantly higher heat transfer coefficients and a higher overall pressure drop.


Author(s):  
Marc Henze ◽  
Christopher Dietz ◽  
Sven Olaf Neumann ◽  
Jens von Wolfersdorf ◽  
Bernhard Weigand

The effect of single full-body Vortex Generators (VGs) on heat transfer was investigated experimentally. The delta shaped devices with different geometries were examined in a rectangular channel for a Reynolds number range of 80,000 up to 600,000. The research included heat transfer as well as flow measurements. Detailed heat transfer results were obtained by a steady state thermochromic liquid crystal (TLC) method using heater foils. This full surface measurement shows heat transfer enhancement evoked by the longitudinal vortices produced by the VGs. Data for secondary flow structures were determined by Particle Image Velocimetry (PIV) measurements. The comparison of vortex position and heat transfer distribution shows that the local heat transfer maximum due to downflow regions of the secondary flow does occur at positions shifted slightly towards the centerline of the channel compared to the existing vortex cores. Experimental data for the flow field were also compared to numerical calculations using FLUENT.


Author(s):  
Justin Lamont ◽  
Sridharan Ramesh ◽  
Srinath V. Ekkad ◽  
Anil Tolpadi ◽  
Christopher Kaminski ◽  
...  

Detailed heat transfer coefficient distributions have been obtained for narrow diverging channels with and without enhancement features. The cooling configurations considered include rib turbulators and concavities (or dimples) on the main heat transfer surfaces. All the measurements are presented at a representative Reynolds number of 28,000. Pressure drop measurements for the overall channel are also presented to evaluate the heat transfer enhancement geometry with respect to pumping power requirements. The test models were studied for wall heat transfer coefficient measurements using the transient liquid crystal technique. The model wall inner surfaces were sprayed with thermochromic liquid crystals, and a transient test was used to obtain the local heat transfer coefficients from the measured color change. Analysis of results shows that choice of designs is limited by available pressure drop even if the design provides significantly higher heat transfer coefficients. Dimpled surfaces provide appreciably high heat transfer coefficients and reasonable pressure drop whereas ribbed ducts provide significantly higher heat transfer coefficients and higher overall pressure drop.


Sign in / Sign up