Heat Transfer Enhancement in Narrow Diverging Channels

2013 ◽  
Vol 135 (4) ◽  
Author(s):  
Justin Lamont ◽  
Sridharan Ramesh ◽  
Srinath V. Ekkad ◽  
Anil Tolpadi ◽  
Christopher Kaminski ◽  
...  

Detailed heat transfer coefficient distributions have been obtained for narrow diverging channels with and without enhancement features. The cooling configurations considered include rib turbulators and concavities (or dimples) on the main heat transfer surfaces. All of the measurements are presented at a representative Reynolds number of 28,000. Pressure drop measurements for the overall channel are also presented to evaluate the heat transfer enhancement geometry with respect to the pumping power requirements. The test models were studied for wall heat transfer coefficient measurements using the transient liquid crystal technique. The model wall inner surfaces were sprayed with thermochromic liquid crystals and a transient test was used to obtain the local heat transfer coefficients from the measured color change. An analysis of the results shows that the choice of designs is limited by the available pressure drop, even if the design provides significantly higher heat transfer coefficients. Dimpled surfaces provide appreciably high heat transfer coefficients and a reasonable pressure drop, whereas ribbed ducts provide significantly higher heat transfer coefficients and a higher overall pressure drop.

Author(s):  
Justin Lamont ◽  
Sridharan Ramesh ◽  
Srinath V. Ekkad ◽  
Anil Tolpadi ◽  
Christopher Kaminski ◽  
...  

Detailed heat transfer coefficient distributions have been obtained for narrow diverging channels with and without enhancement features. The cooling configurations considered include rib turbulators and concavities (or dimples) on the main heat transfer surfaces. All the measurements are presented at a representative Reynolds number of 28,000. Pressure drop measurements for the overall channel are also presented to evaluate the heat transfer enhancement geometry with respect to pumping power requirements. The test models were studied for wall heat transfer coefficient measurements using the transient liquid crystal technique. The model wall inner surfaces were sprayed with thermochromic liquid crystals, and a transient test was used to obtain the local heat transfer coefficients from the measured color change. Analysis of results shows that choice of designs is limited by available pressure drop even if the design provides significantly higher heat transfer coefficients. Dimpled surfaces provide appreciably high heat transfer coefficients and reasonable pressure drop whereas ribbed ducts provide significantly higher heat transfer coefficients and higher overall pressure drop.


Author(s):  
Jatuporn Kaew-On ◽  
Somchai Wongwises

The evaporation heat transfer coefficients and pressure drops of R-410A and R-134a flowing through a horizontal-aluminium rectangular multiport mini-channel having a hydraulic diameter of 3.48 mm are experimentally investigated. The test runs are done at refrigerant mass fluxes ranging between 200 and 400 kg/m2s. The heat fluxes are between 5 and 14.25 kW/m2, and refrigerant saturation temperatures are between 10 and 30 °C. The effects of the refrigerant vapour quality, mass flux, saturation temperature and imposed heat flux on the measured heat transfer coefficient and pressure drop are investigated. The experimental data show that in the same conditions, the heat transfer coefficients of R-410A are about 20–50% higher than those of R-134a, whereas the pressure drops of R-410A are around 50–100% lower than those of R-134a. The new correlations for the evaporation heat transfer coefficient and pressure drop of R-410A and R-134a in a multiport mini-channel are proposed for practical applications.


2008 ◽  
Author(s):  
Pradeep A. Patil ◽  
S. N. Sapali

An experimental test facility is designed and built to calculate condensation heat transfer coefficients and pressure drops for HFC-134a, R-404A, R-407C, R-507A in a smooth and micro-fin tube. The main objective of the experimentation is to investigate the enhancement in condensation heat transfer coefficient and increase in pressure drop using micro-fin tube for different condensing temperatures and further to develop an empirical correlation for heat transfer coefficient and pressure drop, which takes into account the micro-fin tube geometry, variation of condensing temperature and temperature difference (difference between condensing temperature and average temperature of cooling medium). The experimental setup has a facility to vary the different operating parameters such as condensing temperature, cooling water temperature, flow rate of refrigerant and cooling water etc and study their effect on heat transfer coefficients and pressure drops. The hermetically sealed reciprocating compressor is used in the system, thus the effect of lubricating oil on the heat transfer coefficient is taken in to account. This paper reports the detailed description of design and development of the test apparatus, control devices, instrumentation, and the experimental procedure. It also covers the comparative study of experimental apparatus with the existing one from the available literature survey. The condensation and pressure drop of HFC-134a in a smooth tube are measured and obtained the values of condensation heat transfer coefficients for different mass flux and condensing temperatures using modified Wilson plot technique with correlation coefficient above 0.9. The condensation heat transfer coefficient and pressure drop increases with increasing mass flux and decreases with increasing condensing temperature. The results are compared with existing available correlations for validation of test facility. The experimental data points have good association with available correlations except Cavallini-Zecchin Correlation.


Author(s):  
Wei Li ◽  
Dan Huang ◽  
Zan Wu ◽  
Hong-Xia Li ◽  
Zhao-Yan Zhang ◽  
...  

An experimental investigation was performed for convective condensation of R410A inside four micro-fin tubes with the same outside diameter (OD) 5 mm and helix angle 18°. Data are for mass fluxes ranging from about 180 to 650 kg/m2s. The nominal saturation temperature is 320 K, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that Tube 4 has the best thermal performance for its largest condensation heat transfer coefficient and relatively low pressure drop penalty. Condensation heat transfer coefficient decreases at first and then increases or flattens out gradually as G decreases. This complex mass-flux effect may be explained by the complex interactions between micro-fins and fluid. The heat transfer enhancement mechanism is mainly due to the surface area increase over the plain tube at large mass fluxes, while liquid drainage and interfacial turbulence play important roles in heat transfer enhancement at low mass fluxes. In addition, the experimental data was analyzed using seven existing pressure-drop and four heat-transfer models to verify their respective accuracies.


2001 ◽  
Author(s):  
Srinath V. Ekkad ◽  
Hasan Nasir

Abstract Detailed heat transfer measurements are presented for a rectangular channel with dimples on one wall. Dimpled surfaces provide high heat transfer enhancement comparable to ribbed surfaces with reduced overall pressure drop. The heat transfer coefficients were measured using a transient liquid crystal technique. The effect of channel flow Reynolds number was investigated for a wide range from 10000 to 65000. The channel is a 25.4 mm × 101.6 mm (1” × 4”) rectangular cross-section with the dimples on one of the 101.6 mm wall. Heat transfer enhancement around three times that of a smooth channel were achieved for all flow conditions. The overall pressure drop through the dimpled section of the passage was also measured. The resulting thermal performance of the dimples surfaces is significantly higher compared to channels with protruding ribs.


Author(s):  
M. A. Akhavan-Behabadi ◽  
M. Ghazvini ◽  
E. Rasouli

In this study, the effect of adding nanodiamond powder as an additive to engine oil on laminar flow heat transfer enhancement and pressure drop increasing is experimentally investigated. The plain and microfin tubes were used as the test sections and were heated by an electrical coil heater to produce constant heat fluxes. Thermal conductivity and heat capacity of nanofluids were measured for different volume fractions and temperatures. Convection heat transfer coefficients and Nusselt numbers of nanofluids were obtained for different nanoparticle concentrations as well as various Peclet and Reynolds numbers. Experimental results show the enhancement of heat transfer due to the nanoparticles presence. Furthermore, the effect of particle concentration on pressure drop was studied for different heat fluxes. Finally, the performance evaluation of both nanofluid and microfin tube from the point view of heat transfer enhancement and pressure drop increasing is done.


2009 ◽  
Vol 132 (2) ◽  
Author(s):  
Ioannis Ieronymidis ◽  
David R. H. Gillespie ◽  
Peter T. Ireland ◽  
Robert Kingston

Detailed measurements of the heat transfer coefficient (htc) distributions on the internal surfaces of a novel gas turbine blade cooling configuration were carried out using a transient liquid crystal technique. The cooling geometry, in which a series of racetrack passages are connected to a central plenum, provides high heat transfer coefficients in regions of the blade in good thermal contact with the outer blade surface. The Reynolds number changes along its length because of the ejection of fluid through a series of 19 transfer holes in a staggered arrangement, which are used to connect ceramic cores during the casting process. Heat transfer coefficient distributions on these holes surface are particularly important in the prediction of blade life, as are heat transfer coefficients within the hole. The results at passage inlet Reynolds numbers of 21,667, 45,596, and 69,959 are presented along with in-hole htc distributions at Rehole=5930, 12,479, 19,147; and suction ratios of 0.98, 1.31, 2.08, and 18.67, respectively. All values are engine representative. Characteristic regions of high heat transfer downstream of the transfer holes were observed with enhancement of up to 92% over the Dittus–Boelter level. Within the transfer holes, the average htc level was strongly affected by the cross-flow at the hole entrance. htc levels were low in these short (l/d=1.5) holes fed from regions of developed boundary layer.


2018 ◽  
Vol 26 (03) ◽  
pp. 1850022 ◽  
Author(s):  
Sanjeev Singh ◽  
Rajeev Kukreja

Condensation heat transfer coefficients and pressure drops of HFC refrigerants R-134a and R-410A have been investigated experimentally in smooth and micro-fin tubes (helix angles 18[Formula: see text] and 15[Formula: see text]) of outer diameter 9.52[Formula: see text]mm at mass fluxes from 200 to 600[Formula: see text]kg/m[Formula: see text]s, vapor qualities between 0.1 and 0.9 and at saturation temperatures of 35[Formula: see text]C and 40[Formula: see text]C. Results showed that the heat transfer coefficients of R-134a and R-410A inside micro-fin tubes were 1.21–1.82 and 1.15–1.47 times higher and frictional pressure drops were 2.11–2.56 and 1.62–2.12 times higher than those of smooth tubes. These experimental results are compared with the existing heat transfer and frictional pressure drop correlations proposed by different researchers. The comparison showed fairly good agreement with these existing correlations within [Formula: see text]30%. A new correlation has also been proposed for predicting heat transfer coefficient in micro-fin tubes. The oil concentrations measured for refrigerants R-134a and R-410A varied in the range of 1.3–1.5%, respectively.


Author(s):  
S. Naik ◽  
S. Retzko ◽  
M. Gritsch ◽  
A. Sedlov

The trailing edge region of gas turbine blades is generally subjected to extremely high external heat loads due to the combined effects of high mach numbers and gas temperatures. In order to maintain the metal temperatures of these trailing edges to a level, which fulfils both the part mechanical integrity and turbine performance, highly efficient and reliable cooling of the trailing edges is required without increasing the coolant consumption. In this paper, the heat transfer and pressure drop characteristic of three different turbulator designs in a very high aspect ratio passage have been investigated. The turbulator designs included angled and tapered ribs, broken discrete ribs and V-shaped small chevrons ribs. The heat transfer and pressure drop characteristics of all the turbulator configurations was initially investigated via numerical predictions and subsequently in a scaled experimental perspex model. The experimental study was conducted for a range of operational Reynolds numbers and the TLC (thermochromic liquid crystal) method was used to measure the detailed heat transfer coefficients on all surfaces of the passage. Pressure taps were located at several locations within the perspex model and both the local and average heat transfer coefficients and pressure loss coefficients were determined. The measured and predicted results show, that for all cases investigated, the local internal heat transfer coefficient, which is driven by the highly three dimensional passage flows, is highly non-uniformly within the passage. The highest overall average heat transfer was obtained for the angled and tapered turbulator. Although the average heat transfer coefficient of the discrete broken turbulator and the small chevron turbulator were slightly lower than the baseline case, they had much higher pressure losses. In terms of the overall non-dimensional performance index, which incorporates both the heat transfer and the pressure drop, it was found that the angled and tapered turbulator gave the best overall performance.


Author(s):  
Fei Xue ◽  
Mohammad E. Taslim

Impingement cooling in airfoils cooling cavities, solely or combined with film and convective cooling, is a common practice in gas turbines. Depending on the cooling cavity design, the mass flow rate through individual crossover holes could vary significantly in the flow direction thus creating jets of different strengths in the target cavity. This jet flow variation, in turn, creates an impingement heat transfer coefficient variation along the channel. A test section, simulating two adjacent cooling cavities on the trailing side of an airfoil, is made up of two channels with trapezoidal cross-sectional areas. On the partition wall between the two channels, eleven crossover holes create the jets. Two distinct exit flow arrangements are investigated — a) jets, after interaction with the target surface, are turned towards the target channel exit axially and b) jets are exited from a row of racetrack-shaped slots along the target channel. Flow measurements are reported for individual holes and heat transfer coefficients on the eleven target walls downstream the jets are measured using the steady-state liquid crystal thermography technique. Smooth as well as rib-roughened target surfaces with four rib geometries (0°,45°, 90° and 135° rib angles) are tested. Correlations are developed for mass flow rate through each crossover hole for cases with different number of crossover holes, based on the pressure drop across the holes. Heat transfer coefficient variations along the target channel for all rib geometries and flow conditions are reported for a range of 5000 to 50000 local jet Reynolds numbers. Major conclusions of this study are: 1) A correlation is developed to successfully predict the mass flow rates through individual crossover holes for geometries with six to eleven crossover holes, based on the pressure drop across the holes, 2) impingement heat transfer coefficient correlates well with the local jet Reynolds number for both exit flow arrangements, and 3) the case of axial flow in the target channel exiting from the channel end, at higher jet Reynolds numbers, produced higher heat transfer coefficients than those in the case of flow exiting through a row of slots along the target channel opposite to the crossover holes.