scholarly journals Experimental Investigation of the Physical and Mechanical Properties of Sisal Fiber-Reinforced Concrete

Fibers ◽  
2018 ◽  
Vol 6 (3) ◽  
pp. 53 ◽  
Author(s):  
Abass Okeola ◽  
Silvester Abuodha ◽  
John Mwero

Concrete is a very popular material in the construction industry—it is, however, susceptible to quasi-brittle failure and restricted energy absorption after yielding. The incorporation of short discrete fibers has shown great promise in addressing these shortfalls. A natural fiber such as sisal is renewable, cheap, and easily available. It has also exhibited good tensile strength and can significantly improve the performance of concrete. In this study, the physical and mechanical properties of sisal fiber-reinforced concrete were reported. Sisal fibers were added in the mix at percentages of 0.5%, 1.0%, 1.5%, and 2.0% by weight of cement. Physical properties measured are workability, water absorption, and density while mechanical properties reported are compression strength, split tensile strength, and static modulus of elasticity. The computed modulus of elasticity of sisal fiber-reinforced concrete was compared with predicted values in some common design codes. From the study, it was concluded that sisal fiber can enhance the split tensile strength and Young’s modulus of concrete but cannot improve its workability, water absorption, and compressive strength.

2018 ◽  
Vol 12 (1) ◽  
pp. 368-382 ◽  
Author(s):  
Abass Abayomi Okeola ◽  
Silvester Ochieng Abuodha ◽  
John Mwero

Introduction: Fiber reinforced concrete is becoming popular in improving the quasi-brittle failure of concrete. Natural fibers such as sisal holds great promise in this regard. It has amazing tensile strength and is renewable. This paper presents the result of an investigation carried out on the effect of sisal fiber on the compressive strength, Split tensile strength, failure mode and Poisson ratio of Sisal Fiber-Reinforced Concrete (SFRC). Methods: A mix proportion of 1:1.92:3.68 and w/c ratio of 0.47 for a target compressive strength of 35 MPa was used. Sisal fiber was added at percentages of 0.5%, 1.0%, 1.5%, and 2.0% by weight of cement. The effect of specimen shape on the compressive strength of sisal fiber-reinforced concrete (SFRC) was reported. The compressive strength of cube (150mm X 150mm) and cylinder (150mm diameter and 300mm height) specimen was determined at 7 and 28 days, while Split tensile strength and Poisson ratio were obtained using cylindrical specimen (150mm diameter and 300mm height). Results and Conclusion: The result shows that the addition of sisal fiber slightly reduces the compressive strength of concrete, increases its split tensile strength up to 47.167% of the control specimen, arrests crack propagation and reduces its Poisson ratio. The correlation between the compressive strength of cylindrical and cube specimen was established with a ratio ranging between 0.82 - 0.73. The difference in the compressive strength was found to increase with rise in the percentages of sisal fiber. Based on the ratio and mechanical properties, 1.0% sisal fiber content was recommended as the optimum for reinforcing concrete.


2018 ◽  
Vol 875 ◽  
pp. 174-178
Author(s):  
Bhawat Chaichannawatik ◽  
Athasit Sirisonthi ◽  
Qudeer Hussain ◽  
Panuwat Joyklad

This study presents results of an experimental investigation conducted to investigate the mechanical properties of sisal and glass fiber reinforced concrete. Four basic concrete mixes were considered: 1) Plain concrete (PC) containing ordinary natural aggregates without any fibers, 2) sisal fiber reinforced concrete (SFRC), 3) sisal and glass fiber reinforced concrete (SGFRC), 4, glass fiber reinforced concrete (GFRC). Investigated properties were compressive strength, splitting tensile strength, flexural tensile strength and workability. The results of fiber reinforced concrete mixes were compared with plain concrete to investigate the effect of fibers on the mechanical properties of fiber reinforced concrete. It was determined that addition of different kinds of fibers (natural and synthetic) is very useful to produce concrete. The addition of fibers was resulted into higher compressive strength, splitting and tensile strength. However, the workability of the fiber reinforced concrete was found lower than the plain concrete due to the addition of fibers in the concrete.


2018 ◽  
Vol 80 (5) ◽  
Author(s):  
Agustinus Agus Setiawan ◽  
Fredy Jhon Philip ◽  
Eka Permanasari

The objective of this research is to determine the mechanical properties of the waste-plastic-banner-fiber reinforced concrete: compressive strength, splitting tensile strength, rupture modulus and modulus of elasticity. Concrete mixtures with different proportions of waste plastic banner fiber were produced and tested: 0%, 0.25%, 0.5%, 1.0%, 2.0% of waste plastic banner fiber. The tests showed that the addition of fiber by 0.5% from the total concrete volume will increase the splitting tensile strength by 14.28% and produce the modulus of elasticity as high as 23,025 MPa (up to 12% from the normal mix)  and yield the concrete compressive strength of 35.56 MPa (up to 4.95% of the normal mixture). The rupture modulus will increase by 4.11% as the addition of 0.25% of waste plastic banner fiber. 


2020 ◽  
Vol 14 (2) ◽  
pp. 6734-6742
Author(s):  
A. Syamsir ◽  
S. M. Mubin ◽  
N. M. Nor ◽  
V. Anggraini ◽  
S. Nagappan ◽  
...  

This study investigated the combine effect of 0.2 % drink cans and steel fibers with volume fractions of 0%, 0.5%, 1%, 1.5%, 2%, 2.5% and 3% to the mechanical properties and impact resistance of concrete. Hooked-end steel fiber with 30 mm and 0.75 mm length and diameter, respectively was selected for this study.  The drinks cans fiber were twisted manually in order to increase friction between fiber and concrete. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the strength performance of concrete, especially the compressive strength, flexural strength and indirect tensile strength. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the compressive strength, flexural strength and indirect tensile strength by 2.3, 7, and 2 times as compare to batch 1, respectively. Moreover, the impact resistance of fiber reinforced concrete has increase by 7 times as compared to non-fiber concretes. Moreover, the impact resistance of fiber reinforced concrete consistently gave better results as compared to non-fiber concretes. The fiber reinforced concrete turned more ductile as the dosage of fibers was increased and ductility started to decrease slightly after optimum fiber dosage was reached. It was found that concrete with combination of 2% steel and 0.2% drink cans fibers showed the highest compressive, split tensile, flexural as well as impact strength.    


2021 ◽  
Vol 11 (17) ◽  
pp. 7926
Author(s):  
Qian Zhang ◽  
Wenqing Zhang ◽  
Yu Fang ◽  
Yongjie Xu ◽  
Xianwen Huang

In order to solve the problem of highly brittle shaft lining under dynamic loading, a combination of hybrid fiber concrete mixed with steel and polypropylene fiber is proposed to make shaft lining. C60, the concrete commonly used in shaft lining, was selected as the reference group. The static mechanical properties, dynamic mechanical properties, and crack failure characteristics of the hybrid fiber concrete were experimentally studied. The test results showed that compared to the reference group concrete, the compressive strength of the hybrid fiber-reinforced concrete did not significantly increase, but the splitting tensile strength increased by 60.4%. The split Hopkinson compression bar results showed that the optimal group peak stress and peak strain of the hybrid fiber concrete increased by 58.2% and 79.2%, respectively, and the dynamic toughness increased by 68.1%. The strain distribution before visible cracks was analyzed by the DIC technology. The results showed that the strain dispersion phenomenon of the fiber-reinforced concrete specimen was stronger than that of the reference group concrete. By comparing the crack failure forms of the specimens, it was found that compared to the reference group concrete, the fiber-reinforced concrete specimens showed the characteristics of continuous and slow ductile failure. The above results suggest that HFRC has significantly high dynamic splitting tensile strength and compressive deformation capacity, as well as a certain anti-disturbance effect. It is an excellent construction material for deep mines under complex working conditions.


2020 ◽  
Vol 32 (2) ◽  
Author(s):  
Sristi Das Gupta ◽  
MD Shahnewaz Aftab ◽  
Hasan Mohammod Zakaria ◽  
Chaity Karmakar

Using natural (Jute) fiber in concrete as a reinforcing material can not only augment the concrete strength but also restrict the use of synthetic fiber which is environmentally detrimental. To achieve this goal, this study evaluated compressive strength, tensile strength and plastic shrinkage of concrete incorporating ‘Natural (Jute)’ fiber of different length (15 mm and 25 mm) with various mix proportions of 0.10%, 0.2%, 0.3% and 0.4% respectively by volume of concrete. Concrete is vulnerable to grow shrinkage cracks because of high evaporation rate in dry and windy conditions. Incorporating of fibers could abate development of this crack. The large length (25 mm) and higher content ( 0.3%) of reinforcing materials (jute fiber) result to the lowering of mechanical properties of JFRC compare to plain concrete. But in the incorporation of short (15 mm) and low fiber content ( 0.3%), enhances the mechanical properties of the same JFRC. Inclusion of 0.3% (15 mm length) fiber gave maximum enhancement of both concrete compressive and tensile strength by 12.4% and 58% respectively compared to the non-fiber reinforced concrete. A drastic suppression of crack occurrence and area of crack between non-fiber reinforced concrete and fiber reinforced concretes was attained. Experimental results of incorporating 0.1–0.4% fiber with 15 mm length in concrete revealed that plastic shrinkage cracks were decreased by 75–99% in contrast to non-fiber reinforced concrete. Therefore, it is concluded that the incorporation of jute fiber in making FRC composite would be one of the favorable methods to enhance the performance of concrete.


2015 ◽  
Vol 10 (4) ◽  
pp. 155892501501000
Author(s):  
Ramesh Kanagavel ◽  
K. Arunachalam

Mechanical properties of quaternary blending cement concrete reinforced with hybrid fibers are evaluated in this experimental study. The steel fibers were added at volume fractions of 0.5%, 1%, and 1.5 % and polypropylene fibers were added at 0.25% and 0.5% by weight of cementitious materials in the concrete mix individually and in hybrid form to determine the compressive strength, split tensile strength, flexural strength and impact resistance for all the mixes. The experimental results revealed that fiber addition improves the mechanical properties and also the ductility and energy absorption of the concrete. The results also demonstrate that the hybrid steel – polypropylene fiber reinforced concrete performs better in compressive strength, split tensile strength, flexural strength and impact resistance than mono steel and mono polypropylene fiber reinforced concrete.


Sign in / Sign up

Export Citation Format

Share Document