scholarly journals Recognition of Variable-Speed Equipment in an Air-Conditioning System Using Numerical Analysis of Energy-Consumption Data

Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4975 ◽  
Author(s):  
Rongjiang Ma ◽  
Xianlin Wang ◽  
Ming Shan ◽  
Nanyang Yu ◽  
Shen Yang

Motor-driven equipment (ME) is one of the key components in an air-conditioning system, which contributes to the vast majority of the total energy consumption by air-conditioning systems. Distinguishing variable- and constant-speed equipment is important since the energy simulation models of the two types differ. Traditionally, types of ME are known in advance, and energy consumption data are consequently analyzed. However, in the application scenarios of energy consumption data mining, precedent information on the ME type could be missing. Thus, this study applies this process in reverse, providing new insight into energy consumption data of ME to recognize variable-speed ME in an air-conditioning system. The energy consumption data of ME in an air-conditioning system implemented in a commercial building were collected and numerically analyzed. A proposed simple parameter, coefficient of the median, and several numerical parameters were calculated and used to distinguish variable- from constant-speed ME. Results showed that the energy consumption data distributions of the two types of ME differed. The proposed coefficient of the median could successfully distinguish variable- from constant-speed ME, and it could be applied as an important step in energy consumption data mining of air-conditioning systems.

2011 ◽  
Vol 33 (4) ◽  
pp. 423-435 ◽  
Author(s):  
Fu Xiao ◽  
XiaoFeng Niu

Liquid desiccant is an energy-saving, environmentally friendly and healthy means of air dehumidification. A liquid desiccant-based all-air air conditioning system is studied by simulation. Two different modes of air mixing between the return air and the fresh air are compared, that is mixing before and mixing after the liquid desiccant dehumidifier, respectively. System performance and total energy consumption of the two modes under different operation conditions are obtained. The results show that mixing air after dehumidification consumes less energy than mixing air before dehumidification. Coefficient of performance (COP) of the all-air system with air mixing after dehumidification is higher. The differences of COP and energy consumption between the two air mixing modes increase when the outdoor air temperature and relative humidity increase. Practical application: Liquid desiccant based all-air system is quite suitable for museums, libraries and computer centres where water is not allowed to enter the space for property safety and strict thermal-hygrometric control is necessary. The results of this paper provide guidelines on the selection of air mixing modes in liquid desiccant-based all-air systems, considering energy consumption and system COP.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 81
Author(s):  
Rongjiang Ma ◽  
Shen Yang ◽  
Xianlin Wang ◽  
Xi-Cheng Wang ◽  
Ming Shan ◽  
...  

Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2014 ◽  
Vol 628 ◽  
pp. 332-337
Author(s):  
Xiao Xia Xia ◽  
Nai Jun Zhou ◽  
Zhi Qi Wang

The energy consumption of several central air conditioning systems in summer was researched by the method of exergy analysis. Combined with actual example,the exergy loss of all the equipments and the exergy efficiency of three systems were calculated. The results show that the exergy efficiency of three systems is very low. Relatively speaking, the exergy efficiency of primary return air conditioning system with supplying air in dew point is highest. The equipment of highest exergy loss is air-conditioned room, while the exergy loss of surface air cooler is smallest. Based on this, several improvement measures were proposed to reduce exergy loss and improve exergy efficiency.


2014 ◽  
Vol 494-495 ◽  
pp. 1674-1677
Author(s):  
Bing Xu ◽  
Fang Hong Yuan ◽  
Bao Guo Zheng ◽  
Zhong Jin Shi ◽  
Yi Huan Hu

This article discusses energy conservation for air conditioning systems in rail transit stations. At first, the paper analyzes the energy consumption condition in the air conditioning systems in rail transit stations. Then, it discusses application of appropriate control strategy for reducing energy consumption. In the end, the paper calculates effiency and amount of the energy saving based on the control strategy.


2020 ◽  
Vol 2 (3) ◽  
pp. 168-174
Author(s):  
P. Hengjinda ◽  
Dr. Joy Iong Zong Chen

Air conditioning systems were invented to improve human comfort in a room or hall. An efficient air conditioner systems are always needed to minimize the power consumption. There are several settings with lot of control devices were introduced in the past years to achieve minimal energy consumption rate. Those control systems were minimized the energy consumption to certain limit without considering human comfort. The proposed model is designed to minimize the energy consumption with maximum human comfort. Several sensor modules were introduced in the model to predict human comfort level in a room or hall. The sensor data are taken as feedback to the air conditioning system for attaining maximum human comfort level. The proposed design is verified with energy consumption calculation and change in room temperature measurements.


Author(s):  
V. R. Taurit ◽  
◽  
I. I. Sukhanova ◽  
A. N. Kolosnitsyn ◽  
◽  
...  

The problem of significantly reducing the consumption of ventilation air in ducted air conditioning systems by optimizing the efficiency of the air distributor is solved. Unconventional falling non-isothermal jets are experimentally investigated by numerical method with the identification of the structure features and determination of the calculated coefficients m and n according to the proposed methodology. The possibilities of reducing energy consumption by increasing the initial temperature difference of the supply duct air are shown.


2013 ◽  
Vol 724-725 ◽  
pp. 1506-1509
Author(s):  
Guang Ming Zhang ◽  
Xue Shen ◽  
Gui Zhong Tang

The working environment of air conditioning system in large-scale building is very complex, and there is no significant linear relationship between factors affecting energy consumption and energy demand of air conditioning system. This study adopts a nonlinear regression model: ANN (artificial neural network) model as energy model of air conditioning system. Take outdoor temperature, categorical day-of-week variable, equipment efficiency and terminal load as input, energy demand as output. Use energy consumption data in 2011 for network training, and energy consumption data in 2012 to verify the reliability of model. Based on energy analysis, the operation condition and the characteristics of energy consumption of air conditioning system for large-scale buildings in Nanjing could be precisely represented.


2020 ◽  
Vol 10 (11) ◽  
pp. 3721
Author(s):  
Tsung-Yi Chien ◽  
Ching-Chieh Liang ◽  
Feng-Jen Wu ◽  
Chi-Tsung Chen ◽  
Ting-Hsin Pan ◽  
...  

As controlling temperature and humidity is crucial for maintaining comfort and preventing microbial growth, operating rooms (ORs) are the most energy-intensive areas in hospitals. We aimed to evaluate the energy consumption of three dehumidification air conditioning systems used in ORs and their corresponding air quality for ORs at rest. This study selected three ORs using a conventional heating, ventilation, and air conditioning (HVAC) system; a liquid desiccant air conditioning (LDAC) system; and a rotary desiccant air conditioning (RDAC) system, respectively. The indoor thermal–hygrometric conditions, air quality, and energy consumption of the ORs were monitored in this study. The median levels of relative humidity (RH) were 66.7% in the OR using the conventional HVAC system, 60.8% in the OR using the LDAC system, and 60.5% in the OR using the RDAC system. The median daily total energy consumption of the RDAC system (10.1 kWh/m2) and LDAC system (11.8 kWh/m2) were 28.12% and 16.54% lower, respectively, than that of the conventional HVAC system (14.1 kWh/m2). The PM≥0.5 levels and airborne bacterial concentrations in the ORs met the ISO 14644-1 Class 7 standard and China’s GB50333-2013 standard, respectively. The RDAC system was clearly superior to the LDAC and conventional HVAC systems in terms of energy consumption.