scholarly journals Comparative Analysis of Energy Consumption, Indoor Thermal–Hygrometric Conditions, and Air Quality for HVAC, LDAC, and RDAC Systems Used in Operating Rooms

2020 ◽  
Vol 10 (11) ◽  
pp. 3721
Author(s):  
Tsung-Yi Chien ◽  
Ching-Chieh Liang ◽  
Feng-Jen Wu ◽  
Chi-Tsung Chen ◽  
Ting-Hsin Pan ◽  
...  

As controlling temperature and humidity is crucial for maintaining comfort and preventing microbial growth, operating rooms (ORs) are the most energy-intensive areas in hospitals. We aimed to evaluate the energy consumption of three dehumidification air conditioning systems used in ORs and their corresponding air quality for ORs at rest. This study selected three ORs using a conventional heating, ventilation, and air conditioning (HVAC) system; a liquid desiccant air conditioning (LDAC) system; and a rotary desiccant air conditioning (RDAC) system, respectively. The indoor thermal–hygrometric conditions, air quality, and energy consumption of the ORs were monitored in this study. The median levels of relative humidity (RH) were 66.7% in the OR using the conventional HVAC system, 60.8% in the OR using the LDAC system, and 60.5% in the OR using the RDAC system. The median daily total energy consumption of the RDAC system (10.1 kWh/m2) and LDAC system (11.8 kWh/m2) were 28.12% and 16.54% lower, respectively, than that of the conventional HVAC system (14.1 kWh/m2). The PM≥0.5 levels and airborne bacterial concentrations in the ORs met the ISO 14644-1 Class 7 standard and China’s GB50333-2013 standard, respectively. The RDAC system was clearly superior to the LDAC and conventional HVAC systems in terms of energy consumption.

2011 ◽  
Vol 33 (4) ◽  
pp. 423-435 ◽  
Author(s):  
Fu Xiao ◽  
XiaoFeng Niu

Liquid desiccant is an energy-saving, environmentally friendly and healthy means of air dehumidification. A liquid desiccant-based all-air air conditioning system is studied by simulation. Two different modes of air mixing between the return air and the fresh air are compared, that is mixing before and mixing after the liquid desiccant dehumidifier, respectively. System performance and total energy consumption of the two modes under different operation conditions are obtained. The results show that mixing air after dehumidification consumes less energy than mixing air before dehumidification. Coefficient of performance (COP) of the all-air system with air mixing after dehumidification is higher. The differences of COP and energy consumption between the two air mixing modes increase when the outdoor air temperature and relative humidity increase. Practical application: Liquid desiccant based all-air system is quite suitable for museums, libraries and computer centres where water is not allowed to enter the space for property safety and strict thermal-hygrometric control is necessary. The results of this paper provide guidelines on the selection of air mixing modes in liquid desiccant-based all-air systems, considering energy consumption and system COP.


2013 ◽  
Vol 34 (8) ◽  
pp. 858-860 ◽  
Author(s):  
Santina Iudicello ◽  
Antonello Fadda

Among strategies to reduce surgical site infection (SSI) risk, we concentrate on the optimization of the air quality through the heating, ventilation, and air conditioning (HVAC) system. Current ventilation standards applied by some European countries have been compared and show uncertainty in the criteria for dimensioning the HVAC system. The development of a comprehensive regulation needs further discussion.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4975 ◽  
Author(s):  
Rongjiang Ma ◽  
Xianlin Wang ◽  
Ming Shan ◽  
Nanyang Yu ◽  
Shen Yang

Motor-driven equipment (ME) is one of the key components in an air-conditioning system, which contributes to the vast majority of the total energy consumption by air-conditioning systems. Distinguishing variable- and constant-speed equipment is important since the energy simulation models of the two types differ. Traditionally, types of ME are known in advance, and energy consumption data are consequently analyzed. However, in the application scenarios of energy consumption data mining, precedent information on the ME type could be missing. Thus, this study applies this process in reverse, providing new insight into energy consumption data of ME to recognize variable-speed ME in an air-conditioning system. The energy consumption data of ME in an air-conditioning system implemented in a commercial building were collected and numerically analyzed. A proposed simple parameter, coefficient of the median, and several numerical parameters were calculated and used to distinguish variable- from constant-speed ME. Results showed that the energy consumption data distributions of the two types of ME differed. The proposed coefficient of the median could successfully distinguish variable- from constant-speed ME, and it could be applied as an important step in energy consumption data mining of air-conditioning systems.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 81
Author(s):  
Rongjiang Ma ◽  
Shen Yang ◽  
Xianlin Wang ◽  
Xi-Cheng Wang ◽  
Ming Shan ◽  
...  

Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2019 ◽  
Vol 11 (18) ◽  
pp. 5122 ◽  
Author(s):  
Nam-Chul Seong ◽  
Jee-Heon Kim ◽  
Wonchang Choi

This study is aimed at developing a real-time optimal control strategy for variable air volume (VAV) air-conditioning in a heating, ventilation, and air-conditioning (HVAC) system using genetic algorithms and a simulated large-scale office building. The two selected control variables are the settings for the supply air temperature and the duct static pressure to provide optimal control for the VAV air-conditioning system. Genetic algorithms were employed to calculate the optimal control settings for each control variable. The proposed optimal control conditions were evaluated according to the total energy consumption of the HVAC system based on its component parts (fan, chiller, and cold-water pump). The results confirm that the supply air temperature and duct static pressure change according to the cooling load of the simulated building. Using the proposed optimal control variables, the total energy consumption of the building was reduced up to 5.72% compared to under ‘normal’ settings and conditions.


2019 ◽  
Vol 11 (4) ◽  
pp. 1036 ◽  
Author(s):  
Beom-Jun Kim ◽  
Junseok Park ◽  
Jae-Weon Jeong

The main objective of this study is to investigate the indoor air quality enhancement performance of two different liquid desiccant and evaporative cooling-assisted air conditioning systems, such as the variable air volume (VAV) system with the desiccant-enhanced evaporative (DEVap) cooler, and the liquid desiccant system with an indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS), compared with the conventional VAV system. The transient simulations of concentration variations of carbon dioxide (CO2), coarse particles, and fine particles (PM10 and PM2.5) in a model office space served by each system were performed using validated system models that were found in the literature. Based on the hourly thermal loads of the model space predicted by the TRNSYS 18 program, each air conditioning system was operated virtually using a commercial equation solver program (EES). The results indicated that the LD-IDECOAS provided the lowest annual indoor CO2 concentration among all the systems considered in this research, while the VAV system with DEVap cooler exceeded the threshold concentration (i.e., 1000 ppm) during the cooling season (i.e., July, August, and September). For the indoor particulate contaminant concentrations, both liquid desiccant and evaporative cooling-assisted air conditioning systems indicated lower indoor PM2.5 and PM10 concentrations compared with the reference system. The LD-IDECOAS and the VAV with a DEVap cooler demonstrated 33.3% and 23.5% lower annual accumulated indoor PM10 concentrations than the reference system, respectively. Similarly, the annual accumulated indoor PM2.5 concentration was reduced by 16% using the LD-IDECOAS and 17.1% using the VAV with DEVap cooler.


2014 ◽  
Vol 628 ◽  
pp. 332-337
Author(s):  
Xiao Xia Xia ◽  
Nai Jun Zhou ◽  
Zhi Qi Wang

The energy consumption of several central air conditioning systems in summer was researched by the method of exergy analysis. Combined with actual example,the exergy loss of all the equipments and the exergy efficiency of three systems were calculated. The results show that the exergy efficiency of three systems is very low. Relatively speaking, the exergy efficiency of primary return air conditioning system with supplying air in dew point is highest. The equipment of highest exergy loss is air-conditioned room, while the exergy loss of surface air cooler is smallest. Based on this, several improvement measures were proposed to reduce exergy loss and improve exergy efficiency.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 522
Author(s):  
Su Liu ◽  
Jae-Weon Jeong

This study investigated the annual energy saving potential and system performance of two different evaporative cooling-based liquid desiccant and evaporative cooling-assisted air conditioning systems. One system used an indirect and direct evaporative cooler with a two-stage package to match the target supply air point. The other was equipped with a single-stage, packaged dew-point evaporative cooler that used a portion of the process air, which had been dehumidified in advance. Systems installed with the two evaporative coolers were compared to determine which one was more energy efficient and which one could provide better thermal comfort for building occupants in a given climate zone, using detailed simulation data. The detailed energy consumption data of these two systems were estimated using an engineering equation solver with each component model. The results showed that the liquid desiccant and dew-point evaporative-cooler-assisted 100% outdoor air system (LDEOAS) resulted in approximately 34% more annual primary energy consumption than that of the liquid desiccant and the indirect and direct evaporative-cooler-assisted 100% outdoor air system (LDIDECOAS). However, the LDEOAS could provide drier and cooler supply air, compared with the LDIDECOAS. In conclusion, LDIDECOAS has a higher energy saving potential than LDEOAS, with an acceptable level of thermal comfort.