scholarly journals Improving the Energy Efficiency, Limiting Costs and Reducing CO2 Emissions of a Museum Using Geothermal Energy and Energy Management Policies

Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3192 ◽  
Author(s):  
Gianluca Cadelano ◽  
Francesco Cicolin ◽  
Giuseppe Emmi ◽  
Giulia Mezzasalma ◽  
Davide Poletto ◽  
...  

Museums are major energy consumers amongst buildings, especially if they are housed in historical constructions. Museums usually present high energy demand for the air-conditioning due to their architectonical and structural characteristics, such as the presence of large exhibition rooms and open spaces. At the same time, temperature and humidity have to be strictly controlled in order to assure proper microclimate conditions for the conservation of the housed collections and adequate thermal comfort for visitors and personnel. Moreover, despite being subjected to architectural protection that limits most structural refurbishment interventions, these buildings must be adequate from an energy point of view to allow their reuse or continuity of use according to current quality standards, while retaining their heritage significance. In this awkward context, ground source heat pump working with high temperature terminals is proposed as a viable refurbishment solution. The use of shallow geothermal systems can improve the energy efficiency of the heating ventilation air-conditioning systems and, at the same time, increases the renewable energy source exploitation without affecting the indoor environmental conditions. However, after the interventions, the expected benefits and the sought-after limitation of energy consumption/cost may not occur for different reasons. In fact, even if the installed solution is working perfectly and properly designed, every effort will be in vain if adequate attention is not paid to the management of the plants during the operational phase. This document is meant to evaluate and compare the magnitude that invasive (i.e., technical interventions) and not invasive (i.e., energy management policies) actions respectively and their combined interaction, have on a museum. Through energy simulations it has been possible to quantify the effects that different interventions and energy management strategies had on an existing museum housed in an historical building, from energy consumption, energy costs and CO2 emission standpoints.

Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1775 ◽  
Author(s):  
A S M Monjurul Hasan ◽  
Mohammad Rokonuzzaman ◽  
Rashedul Amin Tuhin ◽  
Shah Md. Salimullah ◽  
Mahfuz Ullah ◽  
...  

Bangladesh faced a substantial growth in primary energy demand in the last few years. According to several studies, energy generation is not the only means to address energy demand; efficient energy management practices are also very critical. A pertinent contribution in the energy management at the industrial sector ensures the proper utilization of energy. Energy management and its efficiency in the textile industries of Bangladesh are studied in this paper. The outcomes demonstrate several barriers to energy management practices which are inadequate technical cost-effective measures, inadequate capital expenditure, and poor research and development. However, this study also demonstrates that the risk of high energy prices in the future, assistance from energy professionals, and an energy management scheme constitute the important drivers for the implementation of energy efficiency measures in the studied textile mills. The studied textile industries seem unaccustomed to the dedicated energy service company concept, and insufficient information regarding energy service companies (ESCOs) and the shortage of trained professionals in energy management seem to be the reasons behind this. This paper likewise finds that 3–4% energy efficiency improvements can be gained with the help of energy management practices in these industries.


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1968 ◽  
Author(s):  
Marek Borowski ◽  
Piotr Mazur ◽  
Sławosz Kleszcz ◽  
Klaudia Zwolińska

The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.


Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 87 ◽  
Author(s):  
Jubran Alshahrani ◽  
Peter Boait

Electricity consumption in the Kingdom of Saudi Arabia (KSA) has grown at an annual rate of about 7% as a result of population and economic growth. The consumption of the residential sector accounts for over 50% of the total energy generation. Moreover, the energy consumption of air-conditioning (AC) systems has become 70% of residential buildings’ total electricity consumption in the summer months, leading to a high peak electricity demand. This study investigates solutions that will tackle the problem of high energy demand associated with KSA’s air-conditioning needs in residential buildings. To reduce the AC energy consumption in the residential sector, we propose the use of smart control in the thermostat settings. Smart control can be utilized by (i) scheduling and advance control of the operation of AC systems and (ii) remotely setting the thermostats appropriately by the utilities. In this study, we model typical residential buildings and, crucially, occupancy behavior based on behavioral data obtained through a survey. The potential impacts in terms of achievable electricity savings of different AC operation modes for residential houses of Riyadh city are presented. The results from our computer simulations show that the solutions intended to reduce energy consumption effectively, particularly in the advance mode of operation, resulted in a 30% to 40% increase in total annual energy savings.


2019 ◽  
Vol 111 ◽  
pp. 01050 ◽  
Author(s):  
Javier M. Rey-Hernández ◽  
Sergio Lorenzo González ◽  
Julio F. San José-Alonso ◽  
Ana Tejero-González ◽  
Eloy Velasco-Gómez ◽  
...  

The high energy consumption, attached to a high energy demand in buildings, has led the development of several research projects with the target of reducing the energy consumption in the buildings. As a result of this high consumption, the increased CO2 emissions that have been generated in recent years, have reached alarming levels, which is why it is necessary to reduce the environmental impact which we are contributing to our planet through the use of energy. The European Directive on Building Performance (EPBD 2018/844/EU), recently updated, requires new buildings to be close to the Zero Energy Buildings (nZEBs), increasing the use of renewable energies on-site, and also highlight how to get to improve the cost-effective renovation of existing buildings with the introduction of building control and automation systems ( smart systems), as well as the energy savings and increase the efficiency of energy systems, by reducing CO2 emissions. The use of new renewable energy technologies integrated in buildings, with the aim of reducing the consumption of the facilities that all nZEB buildings must have, such as the ventilation system used as an Indoor Air Quality (IAQ) control technique. In this study, the energy management of the enthalpy ventilation control system is analysed, where dynamic monitoring is going on in the building controlled through Supervisory Control And Data Acquisition (SCADA), in combination with different ventilation systems as free-cooling, heat recovery and geothermal energy of an Earth Air Heat eXchanger (EAHX), all of them as strategies implemented in a real nZEB building (LUCIA) located on the campus at the University of Valladolid, with the goal of improving energy efficiency in ventilation. In order to get this aims, monitoring data of several energy parameters (temperature, air velocity, air flow rate, enthalpy, etc.) are measurements, they allow us to perform a control of the combined ventilation systems to achieve a high IAQ and analyze an optimization of the energy efficiency of the all systems and to study of energy recovery and savings of carbon emissions that directly affect the reduction of the impact of climate change. The results achieved are the energy efficiency of the building in ventilation and optimum system operation in cooling and heating mode. In addition, by controlling the ventilation, the IAQ of the nZEB building is improved.


2021 ◽  
Vol 16 (1) ◽  
pp. 163-178
Author(s):  
Aboelyazied Kulaib ◽  
Abdulrahim Kalendar ◽  
Shafqat Hussain ◽  
Yousuf Alhendal

ABSTRACT In Kuwait air-conditioning systems consume approximately 70% of the grid energy during the long summer months. In this paper, various practical approaches are investigated to enhance the energy efficiency and decrease the energy consumption of five existing air-conditioned (AC) buildings in Kuwait City. The process of energy management in air-conditioned buildings in Kuwait is overwhelming due to high energy consumption in the building sector. This study proposed an optimization technique for the proper energy management of installed AC systems to target energy-efficient buildings. In this study the aim is to explore the effect of different operating parameters, both theoretically and experimentally, and to contribute to the reduction of AC energy consumption. Consequently, the relationship between the thermal load in the air-conditioned buildings and the actual electrical energy consumption is determined, and remedial measures, along with different recommendations for energy saving, are presented. The actual thermal loads of each selected building were calculated and compared with the installed cooling capacity of the AC systems. From the results obtained it was concluded that, by implementing the suggested remedial measures, the predicted load in the selected buildings could be decreased significantly from the existing installed capacity of the cooling systems. Most of the remedial measures suggested for energy management lead to a reduction in power consumption and increased energy efficiency at different levels based on the specifications of the buildings considered and the AC systems installed, resulting in improved in economy, a reduced carbon footprint, and a cleaner environment.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5101
Author(s):  
Izabela Zimoch ◽  
Ewelina Bartkiewicz ◽  
Joanna Machnik-Slomka ◽  
Iwona Klosok-Bazan ◽  
Adam Rak ◽  
...  

A prerequisite for achieving high energy efficiency of water supply systems (understood as using less energy to perform the same task) is the appropriate selection of all elements and their rational use. Energy consumption in water supply systems (WSS) is closely connected with water demand. Especially in the case of oversized water supply systems for which consumers’ water demand is at least 50% less than previously planned and flow velocity in some parts of the system is below 0.01 m·s−1, this problem of excessive energy consumption can be observed. In the literature, it is difficult to find descriptions and methods of energy management for such a case. The purpose of this study was both an evaluation of the current demand of an oversized WSS and a preliminary technical analysis of the possibility for energy saving. Solutions are presented that resulted in improvements in energy management, thus increasing energy efficiency. The conducted analyses indicate the wide use of numerical, hydraulic models, among others, for the needs of the sustainable oversize water supply systems management in order to improve energy efficiency. Those simulations only give energy consumption results as a first step in the process of decision-making for the modernization process, in which investment costs should be taken into account as a second step. Thus, this paper emphasizes the crucial role of hydraulic models as a good analytical tool used in decision support systems (DSS), especially for large, oversized water supply systems.


2018 ◽  
Vol 1 (3) ◽  
pp. 23 ◽  
Author(s):  
Indra Riyanto ◽  
Lestari Margatama ◽  
H. Hakim ◽  
Martini ◽  
Dicky Hindarto

Although common in developed countries such as Japan and Taiwan, the use of lamps coupled with motion sensors are still uncommon and even rare in Indonesia. Our experiment aims to show that simple installation of commercially available motion sensors can contribute to reduce the electricity bill from the increase of energy efficiency, abundance in availability of energy being the main factor in Indonesian high energy consumption habits. High electricity demand for consumption at current supply level in Indonesia led to the rising cost of electricity bills. This factor is compounded by the fact that many electric generators in Indonesia still use fossil fuels, which contributes to the high basic generation cost. UBL is one of the universities that aim to be a green campus. Our research explores the possibility of installing motion sensors to contribute to the energy efficiency. Although mostly common in developed countries, the use of motion sensors for energy efficiency is still rare, especially in Indonesia. Despite rising cost and supply shortages, Indonesian buildings are still of high energy consumption. Our experiment shows that simple installation of commercially available motion sensors can contribute to reduce the electricity bill from the increase of energy efficiency. One of the efforts to lower energy demand on the consumer side is to use the electricity efficiently, such as turning off lights in a room when it is not in use. This method can be simply done by turning the light switches for office and classrooms, but difficult to do in public spaces such as toilets and corridors. Automatic light switches experimentally installed in sample toilet rooms prove that electricity consumption from the lamps can contribute to the reduction of total weekly energy that translates into Greenhouse Gas emission reduction.


2017 ◽  
Vol 9 (1) ◽  
pp. 5-14 ◽  
Author(s):  
Maryam Hamlehdar ◽  
Alireza Aslani

Abstract Today, the fossil fuels have dominant share of energy supply in order to respond to the high energy demand in the world. Norway is one of the countries with rich sources of fossil fuels and renewable energy sources. The current work is to investigate on the status of energy demand in Norway. First, energy and electricity consumption in various sectors, including industrial, residential are calculated. Then, energy demand in Norway is forecasted by using available tools. After that, the relationship between energy consumption in Norway with Basic economics parameters such as GDP, population and industry growth rate has determined by using linear regression model. Finally, the regression result shows a low correlation between variables.


2021 ◽  
Author(s):  
Isiaka Ajewale Alimi ◽  
Romilkumar K. Patel ◽  
Akeem O. Mufutau ◽  
Nelson J. Muga ◽  
Armando N. Pinto ◽  
...  

Abstract The evolution in the Information and Communications Technologies industry results in excessive energy consumption and carbon dioxide emission in the wireless networks. In this context, energy efficiency in mobile networks has been attracting considerable attention as green communications and operational expenditures reduction depend on it. Although the Internet of Things is to be supported by devices that are low-energy consuming, the power consumption of the huge number to be connected for several applications and services demand significant attention. To offer insights into green communications, this paper reviews various energy efficiency improvement techniques. Also, we consider a hybrid model in which the main grid power and dynamically harvested green energy from renewable energy sources can be leveraged to support the energy demand of the radio access network. In this regard, we reformulate the energy consumption model and consider an energy-efficient power allocation algorithm for green energy optimization. Numerical results show that with resource allocation algorithm exploitation, the energy efficiency can be enhanced. Besides, the amount of the grid energy consumption can be considerably minimized, resulting in the greenhouse gas emissions reduction in the wireless networks.


Author(s):  
V. Nakhodov ◽  
O. Borychenko ◽  
A. Cherniavskyi

Statistics show that energy is one of the highest operating costs in a manufacturing enterprise. So, improving energy efficiency can lead to a significant increase in profits and reduce the impact of the enterprise on the environment. To increase the performance of energy efficiency activities, it is necessary to implement an energy management system. One of the components of this system is energy monitoring, which, in turn, is based on the periodic collection and analysis of data to assess the state of the monitoring objects in terms of energy efficiency. In this paper, the role and place of energy monitoring in the energy management system of an industrial enterprise are noted. The paper proposes the concept of creating energy monitoring system in industrial companies, which is based on the combination of a monitoring system based on specific energy consumption, and usage of group energy characteristics of production facilities. Implementing such energy monitoring systems will allow to conduct operational control of energy efficiency of production facilities by creating individual systems for monitoring energy efficiency, as well as successfully carry out such monitoring at the enterprise and its subdivisions over longer periods of time using specific energy consumption indicators. It also provides general guidelines for conducting energy monitoring. These guidelines were formed based on the results of studying various methods and scientific publications in the field of energy monitoring, as well as on the basis of practical experience in the development and implementation of energy management systems. Particular attention is paid to the issues of processing and analysis of information about the objects of energy monitoring of industrial enterprises. The practical application of the concept of creating energy monitoring systems envisages gradual improvement of the existing monitoring system based on the specific energy consumption, which will be further completely replaced with individual energy efficiency monitoring systems.