scholarly journals Dynamic Simulation Model of Trans-Critical Carbon Dioxide Heat Pump Application for Boosting Low Temperature Distribution Networks in Dwellings

Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 484 ◽  
Author(s):  
Livio de Santoli ◽  
Gianluigi Lo Basso ◽  
Davide Astiaso Garcia ◽  
Giuseppe Piras ◽  
Giulia Spiridigliozzi

This research investigates the role of new hybrid energy system applications for developing a new plant refurbishment strategy to deploy small scale smart energy systems. This work deals with a dynamic simulation of trans-critical carbon dioxide heat pump application for boosting low temperature distribution networks to share heat for dwellings. Heat pumps provide high temperature heat to use the traditional emission systems. The new plant layout consists of an air source heat pump, four trans-critical carbon dioxide heat pumps (CO2-HPs), photovoltaic arrays, and a combined heat and power (CHP) for both domestic hot water production and electricity to partially drive the heat pumps. Furthermore, electric storage devices adoption has been evaluated. That layout has been compared to the traditional one based on separated generation systems using several energy performance indicators. Additionally, a sensitivity analysis on the primary energy saving, primary fossil energy consumptions, renewable energy fraction and renewable heat, with changes in building power to heat ratios, has been carried out. Obtained results highlighted that using the hybrid system with storage device it is possible to get a saving of 50% approximately. Consequently, CO2-HPs and hybrid systems adoption could be a viable option to achieve Near Zero Energy Building (NZEB) qualification.

Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


2021 ◽  
Vol 37 ◽  
pp. 24-30
Author(s):  
O. Shapoval ◽  
N.   Chepurna ◽  
M. Kirichenko

Currently, air-to-water heat pumps are more widely used, which due to the high coefficient of performance reduce energy consumption and negative impact on the environment. They decrease the dependency on costs of energy resources. The work is devoted to solving the urgent problem of improving the efficiency of air heat pumps at low temperature of outdoor air in winter. One of the main problems of an air heat pump is the reduction of productivity when the outdoor air temperature decreases in winter. In this paper, the effectiveness of LG Therma V air-to-water heat pump to provide apartments with heating and hot water supply was analyzed. The heat pump is reversive, which can cool or heat a heat carrier. A four-way valve swithes the coolant flows between air exchangers. On the basis of the obtained results, plots of effectivness of the heat pump dependent on outdoor air temperature are built. It is shown that the effectiveness of the heat pump significantly depends not only on the outside temperature but also on the water temperature at the outlet of the heat pump. The use of heat pumps with a high coefficient of performance can significantly reduce energy costs. The most effective are low-temperature heating systems, in which the water temperature does not exceed 45 °C. The example is floor heating, which requires very low temperature of the floor surface – up to 30 °C. At outdoor air temperature not less than milnus 7 °C the heat pump is effective at higher temperature off heat carrier at output – up to 55 °C. To provide the uninterrupted heat supply, an additional air heater is included. It covers heat load during defrosting and very low outdoor air temperature. On the basis of the conducted researches, the directions of the further experimental and field researches are planned.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4527
Author(s):  
Hao Liu ◽  
Hongyi Zhang ◽  
Saqib Javed

Recent data suggest that heat pumps, despite having the potential to cover over 90% of the global space and water heating demands, only provide less than 5% of global heating. Heat pumps, in general, and ground source heat pumps, specifically, offer significant potential for energy savings and carbon emissions reduction in buildings. The realization of these potential benefits, however, requires proper design, installation, and operation of the entire heat pump system. This paper presents the performance analysis of a Swedish ground source heat pump system providing space heating and hot water to a sports clubhouse. The installation has been carefully instrumented to enable full characterization of the whole system including auxiliary components such as circulation pumps and supplementary heating. Seasonal performance factors, calculated for monthly and annual periods using high-quality, high-resolution measurement data collected over three years of system operation, have been reported based on the SEPEMO (SEasonal PErformance factor and MOnitoring for heat pump systems) and Annex 52 boundary schemes for evaluating and benchmarking the performance of the ground source heat pump system. The auxiliary system components were shown to have a large impact on the overall performance of the system. In particular, the legionella protection system was found to affect performance considerably. Recommendations as to how to improve the performance of the system under study and other similar systems are made from the design, installation, and operation perspectives.


HortScience ◽  
1994 ◽  
Vol 29 (4) ◽  
pp. 249a-249
Author(s):  
Eric A. Lavoie ◽  
Damien de Halleux ◽  
André Gosselin ◽  
Jean-Claude Dufour

The main objective of this research was to produce a simulated model that permitted the evaluation of operating costs of commercial greenhouse tomato growers with respect to heating methods (hot air, hot water, radiant and heat pumps) and the use of artificial lighting for 1991 and 1992. This research showed that the main factors that negatively influence profitability were energy consumption during cold periods and the price of tomatoes during the summer season. The conventional hot water system consumed less energy than the heat pump system and produced marketable fruit yields similar to those from the heat pump system. The hot water system was generally more profitable in regards to energy consumption and productivity. Moreover, investment costs were less; therefore, this system gives best overall financial savings. As for radiant and hot air systems, their overall financial status falls between that of the hot water system and the heat pump. The radiant system proved to be more energy efficient that the hot air system, but the latter produced a higher marketable fruit yield over the 2-year study.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1576
Author(s):  
Piotr Jadwiszczak ◽  
Jakub Jurasz ◽  
Bartosz Kaźmierczak ◽  
Elżbieta Niemierka ◽  
Wandong Zheng

Heating and cooling sectors contribute to approximately 50% of energy consumption in the European Union. Considering the fact that heating is mostly based on fossil fuels, it is then evident that its decarbonization is one of the crucial tasks for achieving climate change prevention goals. At the same time, electricity sectors across the globe are undergoing a rapid transformation in order to accommodate the growing capacities of non-dispatchable solar and wind generators. One of the proposed solutions to achieve heating sector decarbonization and non-dispatchable generators power system integration is sector coupling, where heat pumps are perceived as a perfect fit. Air source heat pumps enable a rapid improvement in local air quality by replacing conventional heating sources, but at the same time, they put additional stress on the power system. The emissions associated with heat pump operation are a combination of power system energy mix, weather conditions and heat pump technology. Taking the above into consideration, this paper presents an approach to estimate which of the mentioned factors has the highest impact on heat pump emissions. Due to low air quality during the heating season, undergoing a power system transformation (with a relatively low share of renewables) in a case study located in Poland is considered. The results of the conducted analysis revealed that for a scenario where an air-to-water (A/W) heat pump is supposed to cover space and domestic hot water load, its CO2 emissions are shaped by country-specific energy mix (55.2%), heat pump technology (coefficient of performance) (33.9%) and, to a lesser extent, by changing climate (10.9%). The outcome of this paper can be used by policy makers in designing decarbonization strategies and funding distribution.


Author(s):  
Z. Sirkо ◽  
◽  
V. Korenda ◽  
I. Vyshnyakov ◽  
O. Protasov ◽  
...  

Heat pump - a device for transferring thermal energy from a source of low potential thermal energy to a consumer with a higher temperature. The thermodynamic cycle of a heat pump is similar to a refrigerating machine. Depending on the principle of operation, heat pumps are divided into compression and absorption. The most commonly used compression heat pumps. In recent years, numerous publications on the use of heat pump technology in heating and hot water supply facilities of various spheres - from individual homes to residential neighborhoods have appeared in various media. The authors of the publication have many years of experience in joint scientific and technical cooperation with leading technical universities and industrial organizations in the field of development and practical use of heat pump technology. The authors analyze the possibilities of introducing heat pumps at enterprises and organizations of the State Reserve System of Ukraine. It has been shown that the amount of expenses in comparison with central heating or operation of gas and electric boilers of similar power is several times smaller. It is noted that the implementation of heat pumps is a promising direction in the use of alternative energy sources to meet the heating, ventilation and hot water supply needs of buildings. The payback period from the introduction of heat pumps at enterprises is 4-9 years, depending on the location of the object and the type of source of low-temperature heat. The article meets the requirements of the State Tax Code of Ukraine and can be recommended for publication.


Solar Energy ◽  
2003 ◽  
Author(s):  
Sadasuke Ito ◽  
Naokatsu Miura ◽  
Yasushi Takano

A photovoltaic and thermal hybrid panel which was made of an aluminum roll -bond panel with a photovoltaic module on the surface was developed recently for use as an evaporator of a heat pump for residential hot water supply and room heating.1) Pressure loss of the refrigerant at the evaporator was large. Therefore, in the present study, shapes of the inlet and the outlet of the panel were modified to reduce pressure loss; also, thermal performance of the heat pump which adopted three evaporator panels connected in series was examined. Total area of the panels was about 1.9 m2 and the rated capacity of the compressor was 250 W. These modifications reduced pressure loss and improved thermal performance. The effect of the location of the feeler bulb on performance of the heat pump was also examined. It was inferred that the feeler bulb fixed on the tube at the outlet of the evaporator should be as close as possible to the evaporator outlet.


2018 ◽  
Vol 8 (10) ◽  
pp. 1973 ◽  
Author(s):  
Adnan Ploskić ◽  
Qian Wang ◽  
Sasan Sadrizadeh

The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops.