High efficiency sub-critical carbon dioxide supplementary heat pump for low temperature climates (energy and exergy analysis)

2019 ◽  
Vol 133 ◽  
pp. 166-176 ◽  
Author(s):  
M. Purjam ◽  
K. Goudarzi
Author(s):  
Mykola Bosiy ◽  
◽  
Olexandr Kuzyk ◽  

The aim of the article is to analyze the literature and scientific publications on the effectiveness of the heat pump in heat supply systems and to study the efficiency of using the steam compression cycle of a heat pump in a heat supply system. Тo conduct energy and exergy analysis of heat pump efficiency indicators, the working fluid of which is freon R134a, when using natural waters as a source of low-potential thermal energy. The article analyzes the literature sources and scientific publications on the effectiveness of the heat pump in heat supply systems. The results of research of efficiency of application of the heat pump in systems of heat supply at use of natural waters as a source of low-potential thermal energy are presented. Energy and exergy analysis of heat pump efficiency indicators, the working fluid of which is R134a freon, was performed. The energy efficiency of the heat pump cycle was determined by the conversion factor of the heat pump. The thermodynamic efficiency of the heat pump in heat supply systems was evaluated using exergetic efficiency, which is one of the main indicators of the efficiency of heat pump processes and cycles. The calculation of energy indicators of the heat pump, such as: specific heat load in the evaporator and condenser, as well as the conversion factor of the heat pump. The calculation of exergetic efficiency for ambient temperature from +10 to -10 ºC. Thus, the energy and exergy analysis of the efficiency of the heat pump, the working fluid of which is Freon R134a with a conversion factor = 4.8. This indicates that the heat pump is a reliable, highly efficient, environmentally friendly source of energy for use in heating systems. A heat pump heating system will always consume less primary energy than traditional heating systems if natural water is used as a low-temperature heat source for the heat pump. The efficiency of the steam compression cycle of the heat pump largely depends on the temperature of low-potential heat sources. The use of HV in heating systems reduces greenhouse gas emissions compared to conventional types of heat supply, which is relevant to the ecological state of the environment.


Author(s):  
Hendri ◽  
Roswati Nurhasanah ◽  
Prayudi ◽  
Suhengki

Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.


2016 ◽  
Vol 180 ◽  
pp. 546-559 ◽  
Author(s):  
Margaret Baccanelli ◽  
Stefano Langé ◽  
Matteo V. Rocco ◽  
Laura A. Pellegrini ◽  
Emanuela Colombo