scholarly journals Compact Galvanically Isolated Architectures for Low-Power DC-DC Converters with Data Transmission

Electronics ◽  
2021 ◽  
Vol 10 (19) ◽  
pp. 2328
Author(s):  
Egidio Ragonese ◽  
Alessandro Parisi ◽  
Nunzio Spina ◽  
Giuseppe Palmisano

This paper reviews state-of-the-art architectures for galvanically isolated DC–DC converters with data transmission for low-power applications. Such applications do not have stringent requirements, in terms of power efficiency, but ask for very compact, highly integrated implementations. To this aim, architecture simplicity is crucial, especially when data transmission and/or output power regulation are required. Since the bottleneck of galvanically isolated systems is the isolation device (i.e., typically a stacked thick oxide or polyimide transformer), the reduction of the number of isolated links, while preserving both power and data functionalities, is the more effective strategy to increase the level of integration, reduce the form factor, and have a lower cost per channel. Specifically, this review compares the pros and cons of different architectures that address this challenge differently from traditional solutions.

Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1186
Author(s):  
Egidio Ragonese ◽  
Nunzio Spina ◽  
Alessandro Parisi ◽  
Giuseppe Palmisano

This paper reviews state‑of-the‑art approaches for galvanically isolated dc-dc converters based on radio frequency (RF) micro-transformer coupling. Isolation technology, integration level and fabrication issues are analyzed to highlight the pros and cons of fully integrated (i.e., two chips) and multichip systems-in-package (SiP) implementations. Specifically, two different basic isolation technologies are compared, which exploit thick‑oxide integrated and polyimide standalone transformers, respectively. To this aim, previously available results achieved on a fully integrated isolation technology (i.e., thick‑oxide integrated transformer) are compared with the experimental performance of a dc-dc converter for 20-V gate driver applications, specifically designed and implemented by exploiting a stand-alone polyimide transformer. The comparison highlights that similar performance in terms of power efficiency can be achieved at lower output power levels (i.e., about 200 mW), while the fully integrated approach is more effective at higher power levels with a better power density. On the other hand, the stand-alone polyimide transformer approach allows higher technology flexibility for the active circuitry while being less expensive and suitable for reinforced isolation.


Author(s):  
Rinkuben N. Patel ◽  
Nirav V. Bhatt

Background: WSN is a network of smart tiny electromechanical devices named as sensors. Sensors perform various tasks like sensing the environment as per its range, transmit the data using transmission units, store the data in the storage unit and perform an action based on captured data. As they are installed in an unfriendly environment, to recharge the sensors are not possible every time which leads to a limited lifetime of a network. To enhance the life of a sensor network, the network required energy-efficient protocols. Various energy-efficient MAC protocols are developed by Research community, but very few of them are integrated with the priority-based environment which performs the priority-based data transmission. Another challenge of WSN is, most of the WSN areas are delay-sensitive because it is implemented in critical fields like military, disaster management, and health monitoring. Energy, Delay, and throughput are major quality factors that affect the sensor network. Objective: In this paper, the aim is to design and develop a MAC Protocol for a field like the military where the system requires energy efficiency and priority-based data transmission. Method: In the proposed model, the cluster-based network with priority queues are formed that can achieve higher power efficiency and less delay for sensitive data. Results: In this research simulation of Proposed MAC, TMAC and SMAC are done with different numbers of nodes, same inter-packet intervals, and variant inter-packet intervals. Based on the script simulation, result graphs are generated. Conclusion: The proposed work achieves greater lifetime compared to TMAC and SMAC using priority-based data transmission.


2012 ◽  
Vol 459 ◽  
pp. 544-548 ◽  
Author(s):  
Wei Liang ◽  
Jian Bo Xu ◽  
Wei Hong Huang ◽  
Li Peng

Network security technology ensures secure data transmission in network. Meanwhile, it brings extra overhead of security system in terms of cost and performance, which seriously affects the rapid development of existing high-speed encryption systems. The existing encryption technology cannot meet the demand of high security, low cost and high real-time. For solving above problems, an ECC encryption engine architecture based on scalable public key cipher and a high-speed configurable multiplication algorithm are designed. The algorithm was tested on FPGA platform and the experiment results show that the system has better computation speed and lower cost overhead. By comparing with other systems, our system has benefits in terms of hardware overhead and encryption time ratio


2020 ◽  
Vol 19 (4) ◽  
pp. 330
Author(s):  
Lei Yan ◽  
Zhengshang Yan ◽  
Zhifang He ◽  
Xiuli Zhang ◽  
Xincong Shi ◽  
...  

Author(s):  
Bin Chen ◽  
Beatriz Ramos Barboza ◽  
Yanan Sun ◽  
Jie Bai ◽  
Hywel R Thomas ◽  
...  

AbstractAlong with horizontal drilling techniques, multi-stage hydraulic fracturing has improved shale gas production significantly in past decades. In order to understand the mechanism of hydraulic fracturing and improve treatment designs, it is critical to conduct modelling to predict stimulated fractures. In this paper, related physical processes in hydraulic fracturing are firstly discussed and their effects on hydraulic fracturing processes are analysed. Then historical and state of the art numerical models for hydraulic fracturing are reviewed, to highlight the pros and cons of different numerical methods. Next, commercially available software for hydraulic fracturing design are discussed and key features are summarised. Finally, we draw conclusions from the previous discussions in relation to physics, method and applications and provide recommendations for further research.


Author(s):  
Sheng Kang ◽  
Guofeng Chen ◽  
Chun Wang ◽  
Ruiquan Ding ◽  
Jiajun Zhang ◽  
...  

With the advent of big data and cloud computing solutions, enterprise demand for servers is increasing. There is especially high growth for Intel based x86 server platforms. Today’s datacenters are in constant pursuit of high performance/high availability computing solutions coupled with low power consumption and low heat generation and the ability to manage all of this through advanced telemetry data gathering. This paper showcases one such solution of an updated rack and server architecture that promises such improvements. The ability to manage server and data center power consumption and cooling more completely is critical in effectively managing datacenter costs and reducing the PUE in the data center. Traditional Intel based 1U and 2U form factor servers have existed in the data center for decades. These general purpose x86 server designs by the major OEM’s are, for all practical purposes, very similar in their power consumption and thermal output. Power supplies and thermal designs for server in the past have not been optimized for high efficiency. In addition, IT managers need to know more information about servers in order to optimize data center cooling and power use, an improved server/rack design needs to be built to take advantage of more efficient power supplies or PDU’s and more efficient means of cooling server compute resources than from traditional internal server fans. This is the constant pursuit of corporations looking at new ways to improving efficiency and gaining a competitive advantage. A new way to optimize power consumption and improve cooling is a complete redesign of the traditional server rack. Extracting internal server power supplies and server fans and centralizing these within the rack aims to achieve this goal. This type of design achieves an entirely new low power target by utilizing centralized, high efficiency PDU’s that power all servers within the rack. Cooling is improved by also utilizing large efficient rack based fans for airflow to all servers. Also, opening up the server design is to allow greater airflow across server components for improved cooling. This centralized power supply breaks through the traditional server power limits. Rack based PDU’s can adjust the power efficiency to a more optimum point. Combine this with the use of online + offline modes within one single power supply. Cold backup makes data center power to achieve optimal power efficiency. In addition, unifying the mechanical structure and thermal definitions within the rack solution for server cooling and PSU information allows IT to collect all server power and thermal information centrally for improved ease in analyzing and processing.


Sign in / Sign up

Export Citation Format

Share Document