scholarly journals Thermodynamic Analysis of Transcritical CO2 Ejector Expansion Refrigeration Cycle with Dedicated Mechanical Subcooling

Entropy ◽  
2019 ◽  
Vol 21 (9) ◽  
pp. 874
Author(s):  
Fu ◽  
Wang ◽  
Zheng ◽  
Yu ◽  
Liu ◽  
...  

: The new configuration of a transcritical CO2 ejector expansion refrigeration cycle combined with a dedicated mechanical subcooling cycle (EMS) is proposed. Three mass ratios of R32/R1234ze(Z) (0.4/0.6, 0.6/0.4, and 0.8/0.2) were selected as the refrigerants of the mechanical subcooling cycle (MS) to further explore the possibility of improving the EMS cycle’s performance. The thermodynamic performances of the new cycle were evaluated using energetic and exergetic methods and compared with those of the transcritical CO2 ejector expansion cycle integrated with a thermoelectric subcooling system (ETS). The results showed that the proposed cycle presents significant advantages over the ETS cycle in terms of the ejector performance and the system energetic and exergetic performances. Taking the EMS cycle using R32/R1234ze(Z) (0.6/0.4) as the MS refrigerant as an example, the improvements in the coefficient of performance and system exergy efficiency were able to reach up to 10.27% and 15.56%, respectively, at an environmental temperature of 35 C and evaporation temperature of −5 C. Additionally, the advantages of the EMS cycle were more pronounced at higher environmental temperatures.

Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 4 ◽  
Author(s):  
Laura Nebot-Andrés ◽  
Daniel Calleja-Anta ◽  
Daniel Sánchez ◽  
Ramón Cabello ◽  
Rodrigo Llopis

Different alternatives are being studied nowadays in order to enhance the behavior of transcritical CO2 refrigeration plants. Among the most studied options, subcooling is one of the most analyzed methods in the last years, increasing cooling capacity and Coefficient Of Performance (COP), especially at high hot sink temperatures. A new cycle, called integrated mechanical subcooling cycle, has been developed, as a total-CO2 solution, to provide the subcooling in CO2 transcritical refrigeration cycles. It corresponds to a promising solution from the point of view of energy efficiency. The purpose of this work is to present, for the first time, thermodynamic analysis of a CO2 refrigeration cycle with integrated mechanical subcooling cycle from first and second law approaches. Using simplified models of the components, the optimum operating conditions, optimum gas-cooler pressure, and subcooling degree are determined in order to obtain the maximum COP. The main energy parameters of the system were analyzed for different evaporation levels and heat rejection temperatures. The exergy destruction was analyzed for each component, identifying the elements of the system that introduce more irreversibilities. It has been concluded that the new cycle could offer COP improvements from 11.7% to 15.9% in relation to single-stage cycles with internal heat exchanger (IHX) at 35 °C ambient temperature.


2014 ◽  
Vol 721 ◽  
pp. 170-173
Author(s):  
Zhi Wen Cheng

In this paper, the theoretical analysis and calculation were put forward for the novel compression refrigeration cycle, new cycle compared with conventional compression refrigeration cycle adding a jet pump and evaporator to reduce throttling losses and improve the compressor inlet pressure. The results show that COP decreases with the increase of condensing temperature, with the increase of evaporation temperature increased, and decreased with the increase of the ejector coefficient. Novel compression refrigeration cycle coefficient of performance than the conventional compression refrigeration system performance coefficient increased by 8-15%.


2012 ◽  
Vol 516-517 ◽  
pp. 1219-1223 ◽  
Author(s):  
Ying Fu Liu ◽  
Guang Ya Jin

Use of vortex tube as an expansion device in transcritical CO2 cycle could reduce the throttle loss and improve the coefficient of performance. In this paper, a vortex tube expansion two-stage transcritical CO2 refrigeration cycle(VTTC) is established and compared to that of the two-stage transcritical CO2 refrigeration cycle with throttle valve(TVTC). Thermodynamic analysis results indicate that there is also an optimum heat rejection pressure for the vortex tube cycle, and the COP improvement is 2.4%~16.3% at given conditions. Decrease in evaporation temperature or increase in gas-cooler outlet temperature decrease the COP, but the COP improvement will increase. The effect of cold mass fraction on the COP is negligible, but the COP improvement will increase fast with the increase of cold mass fraction.


2012 ◽  
Vol 178-181 ◽  
pp. 37-41
Author(s):  
Li Yuan Yin ◽  
Qi Tian ◽  
Fei Fei Zhang

Exergy analysis is used as a tool to analyze the performance of a refrigeration system. In this paper, it is based on the following conditions: the solar radiation is set as 750 W/m2, the refrigerating capacity is 10 kW, R141b is fixed as the refrigerant in the refrigeration cycle and ambient temperature to be the reference temperature is 31°C. The exergy analysis results of the solar ejector refrigeration system shows that irreversible loss comes from all components and depends on the operating temperatures. The exergy efficiency increases with the condensation temperature’s decrease or the evaporation temperature’s increase. In the specific evaporation temperature and condensation temperature, the optimum generating temperature can be get when the system exergy efficiency is at its maximum. For the operating conditions in this paper, the optimum generating temperature is 95°C.


2021 ◽  
Vol 309 ◽  
pp. 01141
Author(s):  
Punit Mishra ◽  
Shubham Soni ◽  
Govind Maheshwari

In this paper, a comparative thermodynamic analysis on energy and exergy viewpoint is done on different low global warming potential (GWP) refrigerants to find the possible alternative of high GWP refrigerant R410A. R410A is used nowadays in air conditioning systems due to its ozone-friendly characteristic as zero ozone depletion potential (ODP=0) but it has high GWP (GWP=1924) that leads to global warming. Now a day’s global warming is considered to be one of the critical aspects when environmental protection is taken into consideration and researchers from every corner of the globe are working to find refrigerants that not only have zero ODP but it has low GWP too. In this analysis, four prospect refrigerants namely R32, R447A, R447B, and R452B have been studied to find their suitability to replace R410A on different performance criteria as the coefficient of performance (COP), power consumption, exergy efficiency, and exergy destruction. Thermodynamic properties of the studied refrigerants have been taken from the Genetron Properties 1.4 software. The result indicates that all the studied refrigerants have better performance characteristics compared to R410A but R447A has maximum COP and exergy efficiency along with the least total exergy destruction that makes it a possible alternate of R410A.


2019 ◽  
pp. 155-161 ◽  
Author(s):  
Ivan Beltran

Environmental temperature has fitness consequences on ectotherm development, ecology and behaviour. Amphibians are especially vulnerable because thermoregulation often trades with appropriate water balance. Although substantial research has evaluated the effect of temperature in amphibian locomotion and physiological limits, there is little information about amphibians living under extreme temperature conditions. Leptodactylus lithonaetes is a frog allegedly specialised to forage and breed on dark granitic outcrops and associated puddles, which reach environmental temperatures well above 40 ˚C. Adults can select thermally favourable microhabitats during the day while tadpoles are constrained to rock puddles and associated temperature fluctuations; we thus established microhabitat temperatures and tested whether the critical thermal maximum (CTmax) of L. lithonaetes is higher in tadpoles compared to adults. In addition, we evaluated the effect of water temperature on locomotor performance of tadpoles. Contrary to our expectations, puddle temperatures were comparable and even lower than those temperatures measured in the microhabitats used by adults in the daytime. Nonetheless, the CTmax was 42.3 ˚C for tadpoles and 39.7 ˚C for adults. Regarding locomotor performance, maximum speed and maximum distance travelled by tadpoles peaked around 34 ˚C, approximately 1 ˚C below the maximum puddle temperatures registered in the puddles. In conclusion, L. lithonaetes tadpoles have a higher CTmax compared to adults, suggesting a longer exposure to extreme temperatures that lead to maintain their physiological performance at high temperatures. We suggest that these conditions are adaptations to face the strong selection forces driven by this granitic habitat.


1996 ◽  
Vol 118 (2) ◽  
pp. 81-88 ◽  
Author(s):  
G. Bisio

Energy storage is a key technology for many purposes and in particular for air conditioning plants and a successful exploitation of solar energy. Thermal storage devices are usually classified as either variable temperature (“sensible heat”) or constant temperature (“latent heat”) devices. For both models a basic question is to determine the efficiency suitably: Only exergy efficiency appears a proper way. The aim of this paper is to examine exergy efficiency in both variable and constant temperature systems. From a general statement of exergy efficiency by the present author, two types of actual definitions are proposed, depending on the fact that the exergy of the fluid leaving the thermal storage during the charge phase can be either totally lost or utilized elsewhere. In addition, specific remarks are made about the exergy of a system in a periodically varying temperature environment.


Entropy ◽  
2019 ◽  
Vol 21 (6) ◽  
pp. 546 ◽  
Author(s):  
Yiqun Li ◽  
Na Li ◽  
Chunhuan Luo ◽  
Qingquan Su

When compared with LiBr/H2O, an absorption refrigeration cycle using CaCl2/H2O as the working pair needs a lower driving heat source temperature, that is, CaCl2/H2O has a better refrigeration characteristic. However, the crystallization temperature of CaCl2/H2O solution is too high and its absorption ability is not high enough to achieve an evaporation temperature of 5 °C or lower. CaCl2-LiNO3-KNO3(15.5:5:1)/H2O was proposed and its crystallization temperature, saturated vapor pressure, density, viscosity, specific heat capacity, specific entropy, and specific enthalpy were measured to retain the refrigeration characteristic of CaCl2/H2O and solve its problems. Under the same conditions, the generation temperature for an absorption refrigeration cycle with CaCl2-LiNO3-KNO3(15.5:5:1)/H2O was 7.0 °C lower than that with LiBr/H2O. Moreover, the cycle’s COP and exergy efficiency with CaCl2-LiNO3-KNO3(15.5:5:1)/H2O were approximately 0.04 and 0.06 higher than those with LiBr/H2O, respectively. The corrosion rates of carbon steel and copper for the proposed working pair were 14.31 μm∙y−1 and 2.04 μm∙y−1 at 80 °C and pH 9.7, respectively, which were low enough for engineering applications.


2016 ◽  
Vol 819 ◽  
pp. 202-206
Author(s):  
Reza Maziar ◽  
Kasni Sumeru ◽  
M.Y. Senawi ◽  
Farid Nasir Ani

In this study, two experiments were performed, one with the conventional compression refrigeration cycle (CRC) and the other with an ejector refrigeration cycle (ERC). The CRC system for automotive air conditioning was designed, fabricated and experiments were conducted. The system was then retrofitted with an ejector as the expansion device and experiments were repeated for the ERC system. Calculations of the entrainment ratio, compressor compression ratio and coefficient of performance (COP) were made for each cycle. The calculations showed that ERC has some advantages over the CRC. In this study, an average improvement of 5% in COP has been obtained for the ERC compared with the CRC.


1967 ◽  
Vol 9 (2) ◽  
pp. 209-218 ◽  
Author(s):  
D. W. Holme ◽  
W. E. Coey

A trial designed to investigate the effects of two environmental temperatures, three feeding regimes and the interactions between them is described. A temperature of 72° F. was better than one of 54° F. for bacon pigs between 40 lb. and 200 lb. weight. The higher temperature resulted in faster growth, more efficient feed conversion and increased length of carcass. Other carcass characteristics were not significantly altered. Ad libitum feeding resulted in faster growth and fatter carcasses than restricted feeding, but did not have a significant effect on efficiency of feed conversion. When feed intake was restricted, feeding pigs once daily or twice daily resulted in similar performance and carcass composition.There was a significant interaction between environmental temperature and feeding method for average daily gain in that pigs fed ad libitum grew faster at the low temperature and pigs fed restricted amounts of feed grew faster at the high temperature. No other interaction reached significant levels.


Sign in / Sign up

Export Citation Format

Share Document