scholarly journals Utility of Scanning Electron Microscopy Elemental Analysis Using the ‘NanoSuit’ Correlative Light and Electron Microscopy Method in the Diagnosis of Lanthanum Phosphate Deposition in the Esophagogastroduodenal Mucosa

Diagnostics ◽  
2019 ◽  
Vol 10 (1) ◽  
pp. 1 ◽  
Author(s):  
Kazuya Shinmura ◽  
Hideya Kawasaki ◽  
Satoshi Baba ◽  
Isao Ohta ◽  
Hisami Kato ◽  
...  

Background: We have recently developed the correlative light and electron microscopy of hematoxylin and eosin (H&E)-stained glass slides using the ‘NanoSuit’ method. The aim of this study is to explore the utility of the new NanoSuit-correlative light and electron microscopy method combined with scanning electron microscopy-energy dispersive X-ray spectroscopy elemental analysis for the diagnosis of lanthanum phosphate deposition in the H&E-stained glass slides. Methods: Nine H&E-stained glass slides of the upper gastrointestinal tract mucosa containing the brown pigmented areas by light microscopic observation, which were suspected as lanthanum phosphate deposition, were observed and analyzed by scanning electron microscopy-energy dispersive X-ray spectroscopy using the NanoSuit-correlative light and electron microscopy method. Results: In all nine slides, the new NanoSuit-correlative light and electron microscopy method combined with scanning electron microscopy-energy dispersive X-ray spectroscopy revealed the accumulation of both lanthanum and phosphorus in the tissue area corresponding to the brown pigment deposition. In addition to the existence of lanthanum phosphate in the stomach and duodenum, known target organs, we observed deposition in the esophagus for the first time. Furthermore, we observed lanthanum phosphate deposition in the background mucosa of stomach containing primary adenocarcinoma. Conclusions: Scanning electron microscopy-energy dispersive X-ray spectroscopy analysis using the NanoSuit-correlative light and electron microscopy method is useful for the diagnosis of lanthanum phosphate deposition in the H&E-stained glass slides. Lanthanum phosphate deposition occurs not only in the stomach and duodenum but also in the esophagus.

2016 ◽  
Vol 674 ◽  
pp. 189-194 ◽  
Author(s):  
Margarita A. Skotnikova ◽  
Galina V. Tsvetkova ◽  
Nikolay A. Krylov ◽  
Evgeniy K. Ivanov ◽  
Viktoriy V. Medvedeva ◽  
...  

In this article by the example of two abrasive materials from oxide of aluminum and nitride of boron, the processes developing in a thin surface layer between a grain of abrasive and the material, processed by microcutting with speeds of 40 and 160 m/s, the preforms from armko-iron, steels R18, 45, H18N10T and alloy titanium VT6 are investigated, using the scanning electron microscopy method.


2014 ◽  
Vol 21 (1) ◽  
pp. 231-238 ◽  
Author(s):  
Eric A. Bushong ◽  
Donald D. Johnson ◽  
Keun-Young Kim ◽  
Masako Terada ◽  
Megumi Hatori ◽  
...  

AbstractThe recently developed three-dimensional electron microscopic (EM) method of serial block-face scanning electron microscopy (SBEM) has rapidly established itself as a powerful imaging approach. Volume EM imaging with this scanning electron microscopy (SEM) method requires intense staining of biological specimens with heavy metals to allow sufficient back-scatter electron signal and also to render specimens sufficiently conductive to control charging artifacts. These more extreme heavy metal staining protocols render specimens light opaque and make it much more difficult to track and identify regions of interest (ROIs) for the SBEM imaging process than for a typical thin section transmission electron microscopy correlative light and electron microscopy study. We present a strategy employing X-ray microscopy (XRM) both for tracking ROIs and for increasing the efficiency of the workflow used for typical projects undertaken with SBEM. XRM was found to reveal an impressive level of detail in tissue heavily stained for SBEM imaging, allowing for the identification of tissue landmarks that can be subsequently used to guide data collection in the SEM. Furthermore, specific labeling of individual cells using diaminobenzidine is detectable in XRM volumes. We demonstrate that tungsten carbide particles or upconverting nanophosphor particles can be used as fiducial markers to further increase the precision and efficiency of SBEM imaging.


2008 ◽  
Vol 587-588 ◽  
pp. 795-799 ◽  
Author(s):  
A. Di Paola ◽  
M. Addamo ◽  
M. Bellardita ◽  
E. García-López ◽  
G. Marcì ◽  
...  

Photoactive films consisting of pure anatase, brookite or rutile were deposited on glass slides by a dip coating process from water dispersions or solutions obtained by using TiCl4 as the precursor. The films were characterized by X-ray diffraction, scanning electron microscopy and atomic force microscopy. The photocatalytic activity of the various samples was evaluated by using the photooxidation of 2-propanol in gas solid regime as probe reaction. Brookite and anatase films showed a good photoactivity degrading the substrate and the propanone produced during the reaction.


Sign in / Sign up

Export Citation Format

Share Document