scholarly journals Steel Fiber Use as Shear Reinforcement on I-Shaped UHP-FRC Beams

2019 ◽  
Vol 9 (24) ◽  
pp. 5526 ◽  
Author(s):  
Umut Hasgul ◽  
Altug Yavas ◽  
Tamer Birol ◽  
Kaan Turker

In the presented paper, the effectiveness of steel fiber use on the shear and flexure behaviors of ultra-high performance concrete (UHPC) beams and the feasibility of steel fibers in place of shear reinforcement were investigated experimentally. In this framework, a total of four I-shaped UHPC beams were produced for a high tensile reinforcement ratio of 2.2%. While two of them were non-fiber UHPC beams with and without the shear reinforcement to show the contribution of steel fibers, the remaining beams were made from the ultra-high performance steel fiber-reinforced concrete (UHP-FRC) having the short straight fibers with 1.5% and 2.5% by volume. The shear and flexural parameters, such as the load–deflection response, cracking pattern, failure mode, deflection, and curvature ductilities were discussed based on the four-point loading test results. While the reference beam without fiber and shear reinforcement failed by the shear with a sudden load drop before the yielding of reinforcement and produced no deflection capability, the inclusion of steel fibers to the UHPC matrix transformed the failure mode from shear to flexure through the fibers’ crack-bridging ability. It might be deduced that the moderate level of steel fiber use in the UHP-FRC beams may take the place of shear reinforcement in practical applications.

Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1525 ◽  
Author(s):  
Altug Yavas ◽  
Cumali Ogun Goker

In the presented paper, the impacts of steel fiber use and tensile reinforcement ratio on shear behavior of Ultra-High Performance Concrete (UHPC) beams were investigated from the point of different tensile reinforcement ratios. In the scope of the experimental program, a total of eight beams consisting of four reinforcement ratios representing low to high ratios ranged from 0.8% to 2.2% were casted without shear reinforcement and subjected to the four-point loading test. While half of the test beams included 30 mm end-hooked steel fibers (SF-UHPC) with 2.0 vol%, the remaining beams were produced without the fiber to show possible effectiveness of the fiber use. The shear performances were discussed in terms of the load—deflection response, cracking pattern and failure mode, first cracking load and ultimate shear strength. In this sense, all the non-fiber beams were failed by shear with a dramatic load drop, regardless of the tensile reinforcement amount, before the yielding of reinforcement and they produced no deflection capability. The test results showed that while the inclusion of steel fibers to the UHPC mixture with low reinforcement ratios changed the failure mode from the shear to flexure, it significantly enhanced the ultimate shear strength in the case of higher reinforcement ratio through the SF-UHPC’ superior mechanical properties and fibers’ crack-bridging ability.


2021 ◽  
Vol 11 (4) ◽  
pp. 1764
Author(s):  
Fernando López Gayarre ◽  
Jesús Suárez González ◽  
Iñigo Lopez Boadella ◽  
Carlos López-Colina Pérez ◽  
Miguel Serrano López

The purpose of this study is to analyze the feasibility of using the ultra-fine waste coming from the granite cutting waste gang saws (GCW-GS) to manufacture ultra-high performance, steel-fiber reinforced concrete (UHPFRC). These machines cut granite blocks by abrasion using a steel blade and slurry containing fine steel grit. The waste generated by gang saws (GCW-GS) contains up to 15% Fe2O3 and up to 5% CaO. This is the main difference from the waste produced by diamond saws (GCW-D). Although this waste is available in large quantities, there are very few studies focused on recycling it to manufacture any kind of concrete. In this study, the replaced material was the micronized quartz powder of natural origin used in the manufacture of UHPRFC. The properties tested include workability, density, compressive strength, elasticity modulus, flexural strength, and tensile strength. The final conclusion is that this waste can be used to manufacture UHPFRC with a better performance than that from diamond saws given that there is an improvement of their mechanical properties up to a replacement of 35%. Even for higher percentages, the mechanical properties are within values close to those of control concrete with small decreases.


2021 ◽  
pp. 136943322098165
Author(s):  
Hossein Saberi ◽  
Farzad Hatami ◽  
Alireza Rahai

In this study, the co-effects of steel fibers and FRP confinement on the concrete behavior under the axial compression load are investigated. Thus, the experimental tests were conducted on 18 steel fiber-reinforced concrete (SFRC) specimens confined by FRP. Moreover, 24 existing experimental test results of FRP-confined specimens tested under axial compression are gathered to compile a reliable database for developing a mathematical model. In the conducted experimental tests, the concrete strength was varied as 26 MPa and 32.5 MPa and the steel fiber content was varied as 0.0%, 1.5%, and 3%. The specimens were confined with one and two layers of glass fiber reinforced polymer (GFRP) sheet. The experimental test results show that simultaneously using the steel fibers and FRP confinement in concrete not only significantly increases the peak strength and ultimate strain of concrete but also solves the issue of sudden failure in the FRP-confined concrete. The simulations confirm that the results of the proposed model are in good agreement with those of experimental tests.


Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 63
Author(s):  
Anna L. Mina ◽  
Michael F. Petrou ◽  
Konstantinos G. Trezos

The scope of this paper is to investigate the performance of ultra-high performance fiber reinforced concrete (UHPFRC) concrete slabs, under projectile impact. Mixture performance under impact loading was examined using bullets with 7.62 mm diameter and initial velocity 800 m/s. The UHPFRC, used in this study, consists of a combination of steel fibers of two lengths: 6 mm and 13 mm with the same diameter of 0.16 mm. Six composition mixtures were tested, four UHPFRC, one ultra-high performance concrete (UHPC), without steel fibers, and high strength concrete (HSC). Slabs with thicknesses of 15, 30, 50, and 70 mm were produced and subjected to real shotgun fire in the field. Penetration depth, material volume loss, and crater diameter were measured and analyzed. The test results show that the mixture with a combination of 3% 6 mm and 3% of 13 mm length of steel fibers exhibited the best resistance to projectile impact and only the slabs with 15 mm thickness had perforation. Empirical models that predict the depth of penetration were compared with the experimental results. This material can be used as an overlay to buildings or to construct small precast structures.


2012 ◽  
Vol 174-177 ◽  
pp. 668-671
Author(s):  
He Ting Zhou

Steel fiber has a fine nature in reinforcing concrete. This essay aims to find out the influence of physical forms of steel fiber on its nature of reinforcement. By comparing two types of cement mortar reinforced by steel fibers, it is found that spiral steel fibers have a better bond strength with matrix than straight ones. Therefore, a conclusion could be drawn that physical forms of the steel fiber play a significant role in steel fiber reinforced concrete, and the experiment also serves a rewarding reference to the application of spiral steel fibers.


Author(s):  
Natalia Sharma

Abstract: Reinforced concrete structures are frequently in need of repair and strengthening as a result of numerous environmental causes, ageing, or material damage under intense stress conditions, as well as mistakes made during the construction process. RC structures are repaired using a variety of approaches nowadays. The usage of FRC is one of the retrofitting strategies. Steel fiber reinforced concrete (SFRC) was used in this investigation because it contains randomly dispersed short discrete steel fibers that operate as internal reinforcement to improve the cementitious composite's characteristics (concrete). The main rationale for integrating small discrete fibers into a cement matrix is to reduce the amount of cement used. The principal reason for incorporating short discrete fibers into a cement matrix is to reduce cracking in the elastic range, increase the tensile strength and deformation capacity and increase the toughness of the resultant composite. These properties of SFRC primarily depend upon length and volume of Steel fibers used in the concrete mixture. In India, the steel fiber reinforced concrete (SFRC) has seen limited applications in several structures due to the lack of awareness, design guidelines and construction specifications. Therefore, there is a need to develop information on the role of steel fibers in the concrete mixture. The experimental work reported in this study includes the mechanical properties of concrete at different volume fractions of steel fibers. These mechanical properties include compressive strength, split tensile strength and flexural strength and to study the effect of volume fraction and aspect ratio of steel fibers on these mechanical properties. However, main aim of the study was significance of reinforced concrete beams strengthened with fiber reinforced concrete layer and to investigate how these beams deflect under strain. The objective of the investigation was finding that applying FRC to strengthen beams enhanced structural performance in terms of ultimate load carrying capacity, fracture pattern deflection, and mode of failure or not.


Author(s):  
Josef Landler ◽  
Oliver Fischer

<p>To design flat slabs directly supported on columns, the punching shear resistance of the slab is a main factor. It can be increased in the vicinity of the slab-column connection with punching shear reinforcement, like bent up bars or shear studs, to bear the high reaction forces. However, the usage of punching shear reinforcement requires the knowledge of special design rules and often leads to problems and deficiencies in construction.</p><p>Fiber reinforced concrete seems to be a promising alternative to conventional punching shear reinforcement. To investigate the load bearing behavior of the slab-column connection using fiber reinforced concrete, a total of eight punching shear tests were performed. The specimens were realized with a typical top and bottom flexural reinforcement, but without punching shear reinforcement. Varied parameters were the slab thickness with 250 mm and 300 mm and the fiber content V<sub>f</sub> with 0.5 Vol.-% and 1.0 Vol.-%. To investigate the influence of modern fiber types, normal- and high-strength steel fibers with normal- and double-hooked-ends were used.</p><p>In all eight experimental tests, the intended punching shear failure was achieved. The capable load using fiber reinforced concrete increased by 20 % to 50 % compared to the reference tests without steel fibers, depending on the fiber type and the fiber content V<sub>f</sub>. Additionally, this load increase was accompanied by a significant improvement in ductility. The post-cracking behavior was noticeably influenced by the used steel fiber type. An influence of the slab thickness or steel fiber type on the shear strength contributed by the fiber reinforced concrete could not be determined.</p>


Materials ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 588 ◽  
Author(s):  
Changyong Li ◽  
Pengran Shang ◽  
Fenglan Li ◽  
Meng Feng ◽  
Shunbo Zhao

With the premise of ensuring workability on a fresh mixture, the volume stability of hardened self-compacting steel fiber reinforced concrete (SFRC) becomes an issue due to the content of cementitious materials increased with the volume fraction of steel fiber. By using the expansive agent to reduce the shrinkage deformation of self-compacting SFRC, the strength reduction of hardened self-compacting SFRC is another issue. To solve these issues, this paper performed an experimental investigation on the workability, shrinkage, and mechanical properties of self-compacting SFRC compared to the self-compacting concrete (SCC) with or without an expansive agent. The calcium-sulfoaluminate expansive agent with content optimized to be 10% mass of binders and the steel fiber with a varying volume fraction from 0.4% to 1.2% were selected as the main parameters. The mix proportion of self-compacting SFRC with expansive agent was designed by the direct absolute volume method, of which the steel fibers are considered to be the distributed coarse aggregates. Results showed that rational high filling and passing ability of fresh self-compacting SFRC was ensured by increasing the binder to coarse-aggregate ratio and the sand ratio in the mix proportions; the autogenous and drying shrinkages of hardened self-compacting SFRC reduced by 22.2% to 3.2% and by 18.5% to 7.3% compared to those of the SCC without expansive agent at a curing age of 180 d, although the expansion effect of expansive agent decreased with the increasing volume fraction of steel fiber; the mechanical properties, including the compressive strength, the splitting tensile strength, and the modulus of elasticity increased with the incorporation of an expansive agent and steel fibers, which met the design requirements.


Author(s):  
Antoine N. Gergess ◽  
Mahfoud Shaikh Al Shabab ◽  
Razane Massouh

High-strength cementitious materials such as high-performance concrete are extensively used for retrofit of reinforced concrete (RC) structures. The effectiveness of these materials is increased when mixed with steel fibers. A commonly used technique for strengthening and repair of RC beams consists of applying high-performance fiber-reinforced concrete jackets around the beam perimeter. This paper investigates the jacketing method for repairing severely damaged RC beams. Four 2 m (6 ft 63/4 in.) long rectangular RC beams, 200 × 300 mm (8 ×12 in.) were initially cast and loaded until failure based on three-point bending tests. The four beams were then repaired by thickening the sides of the damaged RC beams using a commercially available high-strength shrinkage grout with and without steel fibers. Strain and deformation were recorded in the damaged and repaired beams to compare structural performance. It is shown that the flexural strength of the repaired beams is increased and the crack pattern under loading is improved, proving that the proposed repair method can restore the resistance capacity of RC beams despite the degree of damage. A method for repair is proposed and an analytical investigation is also performed to understand the structural behavior of the repaired beams based on different thickening configurations.


Sign in / Sign up

Export Citation Format

Share Document