scholarly journals Thermal-Performance Evaluation of Bicycle Helmets for Convective and Evaporative Heat Loss at Low and Moderate Cycling Speeds

2019 ◽  
Vol 9 (18) ◽  
pp. 3672 ◽  
Author(s):  
Shriram Mukunthan ◽  
Jochen Vleugels ◽  
Toon Huysmans ◽  
Kalev Kuklane ◽  
Tiago Sotto Mayor ◽  
...  

The main objective of the study was to investigate the thermal performance of five (open and closed) bicycle helmets for convective and evaporative heat transfer using a nine-zone thermal manikin. The shape of the thermal manikin was obtained by averaging the 3D-point coordinates of the head over a sample of 85 head scans of human subjects, obtained through magnetic resonance imaging (MRI) and 3D-printed. Experiments were carried out in two stages, (i) a convective test and (ii) an evaporative test, with ambient temperature maintained at 20.5 ± 0.5 °C and manikin skin temperature at 30.5 ± 0.5 °C for both the tests. Results showed that the evaporative heat transfer contributed up to 51%–53% of the total heat loss from the nude head. For the convective tests, the open helmet A1 having the highest number of vents among tested helmets showed the highest cooling efficiency at 3 m/s (100.9%) and at 6 m/s (101.6%) and the closed helmet (A2) with fewer inlets and outlets and limited internal channels showed the lowest cooling efficiency at 3 m/s (75.6%) and at 6 m/s (84.4%). For the evaporative tests, the open helmet A1 showed the highest cooling efficiency at 3 m/s (97.8%), the open helmet A4 showed the highest cooling efficiency at 6 m/s (96.7%) and the closed helmet A2 showed the lowest cooling efficiency at 3 m/s (79.8%) and at 6 m/s (89.9%). Two-way analysis of variance (ANOVA) showed that the zonal heat-flux values for the two tested velocities were significantly different (p < 0.05) for both the modes of heat transfer. For the convective tests, at 3 m/s, the frontal zone (256–283 W/m2) recorded the highest heat flux for open helmets, the facial zone (210–212 W/m2) recorded the highest heat flux for closed helmets and the parietal zone (54–123 W/m2) recorded the lowest heat flux values for all helmets. At 6 m/s, the frontal zone (233–310 W/m2) recorded the highest heat flux for open helmets and the closed helmet H1, the facial zone (266 W/m2) recorded the highest heat flux for the closed helmet A2 and the parietal zone (65–123 W/m2) recorded the lowest heat flux for all the helmets. For evaporative tests, at 3 m/s, the frontal zone (547–615 W/m2) recorded the highest heat flux for all open helmets and the closed helmet H1, the facial zone (469 W/m2) recorded the highest heat flux for the closed helmet A2 and the parietal zone (61–204 W/m2) recorded the lowest heat flux for all helmets. At 6 m/s, the frontal zone (564–621 W/m2) recorded highest heat flux for all the helmets and the parietal zone (97–260 W/m2) recorded the lowest heat flux for all helmets.

1981 ◽  
Vol 103 (2) ◽  
pp. 325-330 ◽  
Author(s):  
R. Cook ◽  
C. Y. Tung ◽  
P. C. Wayner

A scanning microphotometer was used to measure in situ the profile of an evaporating decane meniscus in the contact line region on a smooth inclined silicon substrate as a function of the evaporative heat flux. The use of this new experimental design to determine the effect of heat flux on the profile in the contact line region is discussed. The results support the hypothesis that fluid flow in the contact line region of an evaporating thin film results from a change in the thin film thickness profile.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2145 ◽  
Author(s):  
Ning Qian ◽  
Yucan Fu ◽  
Marco Marengo ◽  
Jiuhua Xu ◽  
Jiajia Chen ◽  
...  

In order to enhance heat transfer in the abrasive-milling processes to reduce thermal damage, the concept of employing oscillating heat pipes (OHPs) in an abrasive-milling tool is proposed. A single-loop OHP (SLOHP) is positioned on the plane parallel to the rotational axis of the tool. In this case, centrifugal accelerations do not segregate the fluid between the evaporator and condenser. The experimental investigation is conducted to study the effects of centrifugal acceleration (0–738 m/s2), heat flux (9100–31,850 W/m2) and working fluids (methanol, acetone and water) on the thermal performance. Results show that the centrifugal acceleration has a positive influence on the thermal performance of the axial-rotating SLOHP when filled with acetone or methanol. As for water, with the increase of centrifugal acceleration, the heat transfer performance first increases and then decreases. The thermal performance enhances for higher heat flux rises for all the fluids. The flow inside the axial-rotating SLOHP is analyzed by a slow-motion visualization supported by the theoretical analysis. Based on the theoretical analysis, the rotation will increase the resistance for the vapor to penetrate through the liquid slugs to form an annular flow, which is verified by the visualization.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1929 ◽  
Author(s):  
M. Sarafraz ◽  
Mohammad Safaei ◽  
Zhe Tian ◽  
Marjan Goodarzi ◽  
Enio Bandarra Filho ◽  
...  

In the present study, we report the results of the experiments conducted on the convective heat transfer of graphene nano-platelets dispersed in water-ethylene glycol. The graphene nano-suspension was employed as a coolant inside a micro-channel and heat-transfer coefficient (HTC) and pressure drop (PD) values of the system were reported at different operating conditions. The results demonstrated that the use of graphene nano-platelets can potentially augment the thermal conductivity of the working fluid by 32.1% (at wt. % = 0.3 at 60 °C). Likewise, GNP nano-suspension promoted the Brownian motion and thermophoresis effect, such that for the tests conducted within the mass fractions of 0.1%–0.3%, the HTC of the system was improved. However, a trade-off was identified between the PD value and the HTC. By assessing the thermal performance evaluation criteria (TPEC) of the system, it was identified that the thermal performance of the system increased by 21% despite a 12.1% augmentation in the PD value. Furthermore, with an increment in the fluid flow and heat-flux applied to the micro-channel, the HTC was augmented, showing the potential of the nano-suspension to be utilized in high heat-flux thermal applications.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Chen-Ching Ting ◽  
Jing-Nang Lee ◽  
Chien-Chih Chen

The article presents some significant experimental data for studying the heat transfer behavior of heat pipe, which will further help the cooling efficiency improvement of the heat pipe cooler. It is well known that the heat pipe owns the extreme large heat conductivity and is often integrated with cooling plates for CPU cooling. The heat pipe uses special heat transfer techniques to obtain extremely large heat conductivity, which are the inside liquid evaporation for heat absorption and the inside microstructural capillarity for condensation. These special techniques yield the instant heat transfer from the heat source to the remote side directly, but the special heat transfer behavior is changed due to the integration with cooling plates. The destroyed heat transfer behavior of the heat pipe causes the cooling efficiency of the heat pipe cooler to be not able to reach a predicted good value. To improve the cooling efficiency of the heat pipe cooler we recover the original heat transfer behavior of the heat pipe integrated with cooling plates. This work first built a CPU simulator in accordance with the ASTM standard for heating the heat pipe, then uses the color schlieren technique to visualize the sequent heat flux nearby the heat pipe and the infrared thermal camera for quantitative temperature measurements synchronously. The result shows that the heat flux first appears at the opposite side from the heat source and there exhibits also the highest temperature. This is different from the heat transfer behavior of the copper pipe. Another very interesting result is that the heat flux of the cooling plate nearest to the heat source is first viewed than the others, which is similar to the integration with the copper pipe.


Author(s):  
Yassine Kharbouch ◽  
Mohamed Ameur

Abstract Climate change has become a real challenge in different fields, including the building sector. Understanding and assessing the impact of climate change on building energy performance is still necessary to elaborate new climate-adaptive design measures for future buildings. The building energy consumption for heating and cooling is mainly related to the building envelope thermal performance. In this study, the winter heat loss and summer heat gain indicators are proposed to assess and analyse the potential impact of climate change on opaque building envelope elements for different climate zones in Morocco over the next 40 years. For that purpose, a one-dimensional heat transfer model is used to simulate the heat transfer through the multi-layer structure of the wall/roof. A medium climate change scenario is considered in this study. The results showed that the current average walls and roof summer heat gain is expected to increase of about 19.2–54.3% by the 2060s depending on the climate zone, versus a less important decrease in winter heat loss varies between –10.6 and –20.6%. This paper provides a reliable evaluation of the climate change impact on building envelope thermal performance, which leads to better adjustments in future building envelope designs.


2020 ◽  
Vol 7 (3) ◽  
pp. 1-13
Author(s):  
A'laa Taghi Al-Azawi ◽  
Ali A. F. Al Hamadani

Abstract— The solar energy is the most important type of energy. The parabolic dish solar collector (PDSC) is the best type among other solar collectors because it is always tracking the sun movement. The exergy and the energy performances of a PDS were analyzed experimentally and numerically. The effect of different coil geometries and different mass flow rates of heat transfer fluid (HTF) were investigated. The PDS has parabolic dish and receiver with diameter (1.5) m and (0.2) m respectively. Concentration ratio is 56.25. The parabolic polar dish was supported by a tracking system with two axes. The types of the copper absorber were used which are: (spiral –helical) coil (SHC) and spiral-conical coil (SCC). The results showed that the useful energy and thermal efficiency are varying with solar radiation variation. The useful energy varying between (480-765) W for (SHC), the thermal efficiency varying between (35.2-39.8) % for (SHC). Exergy efficiency varying between (6.9 –8.6) %. It was shown that the higher values of useful energy for (spiral – helical) absorber was 0.1L/min flow rate. REFERENCES  1. T. Taumoefolau , K. Lovegrove ," An Experimental Study of Natural Convection Heat Loss from a Solar Concentrator Cavity Receiver at Varying Orientation. ", Australian National University,, Canberra ACT 0200 AUSTRALIA.2002  2. S. PAITOONSURIKARN and K. LOVEGROVE," On the Study of Convection Loss from Open Cavity Receivers in Solar Paraboloidal Dish Applications ", Australian National University Canberra ACT 0200, AUSTRALIA, pp 154,155,2003  3. Soteris A. Kalogirou*,"Solar thermal collectors and applications", Higher Technical Institute, Progress in Energy and Combustion Science 30 (2004) 231–295, pp237, 240, 241, 2004  4. M. Prakash, S.B. Kedare, J.K. Nayak," Investigations on heat losses from a solar cavity receiver", Department of Energy Science and Engineering, Indian Institute of Technology Bombay, Mumbai 400076, India,2008.  5. Shiva Gorjian1, Barat Ghobadian1, Teymour Tavakkoli Hashjin1, and Ahmad Banak ,"Thermal performance of a Point-focus Solar Steam Generating System ", 21st Annual International Conference on Mechanical Engineering-ISME201 7-9 May, 2013, School of Mechanical Eng., K.N.Toosi University, Tehran, Iran ,1ISME2013-1195,2013  6. Kailash Karunakaran1 Hyacinth J Kennady2 ,"Thermal Analysis of Parabolic Dish Snow Melting Device " ,International Journal for Research in Technological Studies| Vol. 1, Issue 3, February 2014 | ISSN (online): 2348-1439,2014  7. Charles-Alexis Asselineau, Ehsan Abbasi, John Pye "Open cavity receiver geometry influence on radiative losses" Australian National University (ANU), Canberra, ACT 0200 Australia. Solar2014: The 52nd Annual Conference of the Australian Solar Council 2014  8. Vahid Madadi, Touraj Tavakoli and Amir Rahimi First and second thermodynamic law analyses applied to a solar dish collector" DOI 10.1515/jnet-2014-0023 | J. Non-Equilib. Thermodyn. 2014; 39 (4):183–197  9. Yaseen. H. Mahmood , Mayadah K h. Ghaffar " Design of Solar dish concentration by using MATLAB program and Calculation of geometrical concentration parameters and heat transfer" , University of Tikrit , Tikrit , Iraq, Tikrit Journal of Pure Science 20 (4) ISSN: 1813 – 1662, 2015.  10. Vanita Thakkar, Ankush Doshi, Akshaykumar Rana "Performance Analysis Methodology for Parabolic Dish Solar Concentrators for Process Heating Using Thermic Fluid IOSR", Journal of Mechanical and Civil Engineering (IOSR-JMCE) eISSN: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 1 Ver. II (Jan- Feb. 2015), PP 101-114  11. Saša R. pavlovi, Evangelos A. bellos, Velimir P. Stefanovi, Christos Tzivanidis and Zoran M. Stamenkovi "Design, Simulation ,and Optimiztion Of A Solar Dish Collector with spiral coil absorber ", , Nis, Serbia, thermal SCIENCE, Vol. 20, No. 4, pp. 1387-1397 1387,2016  12. Flávia V. Barbosa, João L. Afonso, Filipe B. Rodrigues, and José C. F. Teixeir," Development of a solar concentrator with tracking system", University of Minho,Guimarães, 4800-058, Portugal2016  13. O. López, A. Arenas, and A. Baños"Convective Heat Loss Analysis of a Cavity Receiver for a Solar Concentrator" International Conference on Renewable Energies and Power Quality (ICREPQ’17)Malaga (Spain), 4th to 6th April, 2017 ,ISSN 2172-038 X, No.15 April 2017 RE&PQJ, Vol.1, No.15, April 2017  14. D.R.Rajendran,E.GanapathySundaram,P.Jawahar "Experimental Studies on the Thermal Performance of a Parabolic Dish Solar Receiver with the Heat Transfer Fluids Sic water Nano Fluid and Water", Journal of Thermal Science Vol.26,  15. Muhammad Shoaib, Muhammad , Jameel Kabbir Ali ,Muhammad Usman1, Abdul Hannan " Analysis of thermal performance of parabolic dish collectors having different reflective" ,NFC institute of engineering &fertilizer research ,2018 .  16. Sasa PAVLOVIC, Evangelos BELLOS, Velimir STEFANOVIC ,Christos TZIVANIDIS " EXPERIMENTAL AND NUMERICAL INVESTIGATION OF A SOLAR DISH COLLECTOR WITH SPIRAL ABSORBER" A CTA TECHNICA CORVINIENSIS – Bulletin of Engineering Tome XI [2018] .   


Author(s):  
Satyendra Singh ◽  
◽  
Tarun Joshi ◽  
Himanshi Kharkwal ◽  
◽  
...  

The heat transfer and fluid flow characteristics in a tube heat exchanger using H-shape inserts with circular ring (CRWHS) has been done by computationally and experimentally. In this investigation parameters like ratio of the diameters and pitches are considered. The value of diameter and pitch ratios are (DR=0.8, 0.9), (PR=3, 4) respectively. The main section in which investigation was done is 1.5m long and the hydraulic diameter of the tube is 68.1mm. 1000 W/m2 heat flux was provided in the main section. Heat flux was constant throughout the investigation. Air is used as a working medium in which 6000 to 21000 Reynolds number was used for the investigation. The observation revealed that the increment in heat transfer rate is 4.56 times as compare to smooth tube for the circular ring with H-shape inserts. In case of DR=0.8 and PR=3, maximum thermal performance factor was obtain which is 3.24. In GIT the deviation in Nusselt number & friction factor is limited to ±0.4% & ±0.1% respectively. CFD analysis result comparisons with experimental one are presented in which the maximum deviations for thermal performance factor are limited to ±3.6%.


2012 ◽  
Vol 27 (1) ◽  
pp. 53-58 ◽  
Author(s):  
Otto Henriksson ◽  
Peter Lundgren ◽  
Kalev Kuklane ◽  
Ingvar Holmér ◽  
Peter Naredi ◽  
...  

AbstractIntroduction: In the prehospital care of a cold and wet person, early application of adequate insulation is of utmost importance to reduce cold stress, limit body core cooling, and prevent deterioration of the patient’s condition. Most prehospital guidelines on protection against cold recommend the removal of wet clothing prior to insulation, and some also recommend the use of a waterproof vapor barrier to reduce evaporative heat loss. However, there is little scientific evidence of the effectiveness of these measures.Objective: Using a thermal manikin with wet clothing, this study was conducted to determine the effect of wet clothing removal or the addition of a vapor barrier on thermal insulation and evaporative heat loss using different amounts of insulation in both warm and cold ambient conditions.Methods: A thermal manikin dressed in wet clothing was set up in accordance with the European Standard for assessing requirements of sleeping bags, modified for wet heat loss determination, and the climatic chamber was set to -15 degrees Celsius (°C) for cold conditions and +10°C for warm conditions. Three different insulation ensembles, one, two or seven woollen blankets, were chosen to provide different levels of insulation. Five different test conditions were evaluated for all three levels of insulation ensembles: (1) dry underwear; (2) dry underwear with a vapor barrier; (3) wet underwear; (4) wet underwear with a vapor barrier; and (5) no underwear. Dry and wet heat loss and thermal resistance were determined from continuous monitoring of ambient air temperature, manikin surface temperature, heat flux and evaporative mass loss rate.Results: Independent of insulation thickness or ambient temperature, the removal of wet clothing or the addition of a vapor barrier resulted in a reduction in total heat loss of 19-42%. The absolute heat loss reduction was greater, however, and thus clinically more important in cold environments when little insulation is available. A similar reduction in total heat loss was also achieved by increasing the insulation from one to two blankets or from two to seven blankets.Conclusion: Wet clothing removal or the addition of a vapor barrier effectively reduced evaporative heat loss and might thus be of great importance in prehospital rescue scenarios in cold environments with limited insulation available, such as in mass-casualty situations or during protracted evacuations in harsh conditions.


Sign in / Sign up

Export Citation Format

Share Document