scholarly journals Near-Infrared C2H2 Detection System Based on Single Optical Path Time Division Multiplexing Differential Modulation Technique and Multi-Reflection Chamber

2019 ◽  
Vol 9 (13) ◽  
pp. 2637 ◽  
Author(s):  
Biao Wang ◽  
Hongfei Lu ◽  
Chen Chen ◽  
Lei Chen ◽  
Houquan Lian ◽  
...  

A time division multiplexing differential modulation technique is proposed to address the interference problem caused by the fluctuation of laser light intensity in the single optical path detection system. Simultaneously, a multi-reflection chamber is designed and manufactured to further improve the system’s precision with an optical path length of 80 m. A near-infrared C2H2 detection system was developed. The absorption peak of the acetylene (C2H2) molecule near 1520 nm was selected as the absorption line. A laser driver is developed, and a lock-in amplifier is used to extract the second harmonic (2f) signal. A good linear relationship existed between C2H2 concentration and the 2f signal, and the correlation coefficient was 0.9997. In the detection range of 10–100 ppmv, the minimum detection limit was 0.3 ppmv, and the precision was 2%. At 50 ppmv, C2H2 and continuous detection for 10 h, the data average was 50.03 ppmv, and the fluctuation was less than ±1.2%. The Allan variance method was adopted to evaluate the long-term characteristic of the system. At 1 s of integration time, the Allan deviation was 0.3 ppmv. When the integration time reached 362 s, the Allan deviation was 0.0018 ppmv, which indicates the good stability of the detection system.

2020 ◽  
Vol 2020 (2) ◽  
pp. 100-1-100-6
Author(s):  
Takuya Omura ◽  
Hayato Watanabe ◽  
Naoto Okaichi ◽  
Hisayuki Sasaki ◽  
Masahiro Kawakita

We enhanced the resolution characteristics of a threedimensional (3D) image using time-division multiplexing methods in a full-parallax multi-view 3D display. A time-division light-ray shifting (TDLS) method is proposed that uses two polarization gratings (PGs). As PG changes the diffraction direction of light rays according to the polarization state of the incident light, this method can shift light rays approximately 7 mm in a diagonal direction by switching the polarization state of incident light and adjusting the distance between the PGs. We verified the effect on the characteristics of 3D images based on the extent of the shift. As a result, the resolution of a 3D image with depth is improved by shifting half a pitch of a multi-view image using the TDLS method, and the resolution of the image displayed near the screen is improved by shifting half a pixel of each viewpoint image with a wobbling method. These methods can easily enhance 3D characteristics with a small number of projectors.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2797
Author(s):  
Jing-Jhong Gao ◽  
Ching-Wei Chiu ◽  
Kuo-Hsing Wen ◽  
Cheng-Sheng Huang

This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500–700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


2021 ◽  
Vol 21 (9) ◽  
pp. 11131-11139
Author(s):  
Sen Wu ◽  
Zhijian Liu ◽  
Kezhen Yu ◽  
Zixiao Fan ◽  
Ziyi Yuan ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3052
Author(s):  
Mas Ira Syafila Mohd Hilmi Tan ◽  
Mohd Faizal Jamlos ◽  
Ahmad Fairuz Omar ◽  
Fatimah Dzaharudin ◽  
Suramate Chalermwisutkul ◽  
...  

Ganoderma boninense (G. boninense) infection reduces the productivity of oil palms and causes a serious threat to the palm oil industry. This catastrophic disease ultimately destroys the basal tissues of oil palm, causing the eventual death of the palm. Early detection of G. boninense is vital since there is no effective treatment to stop the continuing spread of the disease. This review describes past and future prospects of integrated research of near-infrared spectroscopy (NIRS), machine learning classification for predictive analytics and signal processing towards an early G. boninense detection system. This effort could reduce the cost of plantation management and avoid production losses. Remarkably, (i) spectroscopy techniques are more reliable than other detection techniques such as serological, molecular, biomarker-based sensor and imaging techniques in reactions with organic tissues, (ii) the NIR spectrum is more precise and sensitive to particular diseases, including G. boninense, compared to visible light and (iii) hand-held NIRS for in situ measurement is used to explore the efficacy of an early detection system in real time using ML classifier algorithms and a predictive analytics model. The non-destructive, environmentally friendly (no chemicals involved), mobile and sensitive leads the NIRS with ML and predictive analytics as a significant platform towards early detection of G. boninense in the future.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2674
Author(s):  
Qingying Ren ◽  
Wen Zuo ◽  
Jie Xu ◽  
Leisheng Jin ◽  
Wei Li ◽  
...  

At present, the proposed microwave power detection systems cannot provide a high dynamic detection range and measurement sensitivity at the same time. Additionally, the frequency band of these detection systems cannot cover the 5G-communication frequency band. In this work, a novel microwave power detection system is proposed to measure the power of the 5G-communication frequency band. The detection system is composed of a signal receiving module, a power detection module and a data processing module. Experiments show that the detection frequency band of this system ranges from 1.4 GHz to 5.3 GHz, the dynamic measurement range is 70 dB, the minimum detection power is −68 dBm, and the sensitivity is 22.3 mV/dBm. Compared with other detection systems, the performance of this detection system in the 5G-communication frequency band is significantly improved. Therefore, this microwave power detection system has certain reference significance and application value in the microwave signal detection of 5G communication systems.


Sign in / Sign up

Export Citation Format

Share Document