scholarly journals A New Inspiration in Bionic Shock Absorption Midsole Design and Engineering

2021 ◽  
Vol 11 (20) ◽  
pp. 9679
Author(s):  
Hai-Bin Yu ◽  
Rui Zhang ◽  
Guo-Long Yu ◽  
Hai-Tao Wang ◽  
Dao-Chen Wang ◽  
...  

Inspired by the performance of the ostrich in terms of loading and high-speed moving ability, the purpose of this study was to design a structure and material on the forefoot and heel of the middle soles of sports shoes based on the high cushioning quality of the ostrich toe pad by applying bionic engineering technology. The anatomical dissection method was used to analyze the ostrich foot characteristics. The structure and material of the bionic shock absorption midsole were designed according to the principles of bionic engineering and reverse engineering. F-Scan and numerical simulation were used to evaluate the bionic shock absorption midsole performance. The results showed that the bionic shock absorption midsole decreased the peak pressure (6.04–12.27%), peak force (8.62–16.03%), pressure–time integral (3.06–12.66%), and force–time integral (4.06–10.58%) during walking and brisk walking. In this study, the biomechanical effects to which the bionic shock absorption midsole structure was subjected during walking and brisk walking exercises were analyzed. The bionic midsole has excellent shock resistance. It is beneficial for the comfort of the foot during exercise and might reduce the risk of foot injuries during exercise.

PeerJ ◽  
2021 ◽  
Vol 9 ◽  
pp. e12481
Author(s):  
Yuqi He ◽  
Dong Sun ◽  
Xiaoyi Yang ◽  
Gusztáv Fekete ◽  
Julien S. Baker ◽  
...  

Background Biomechanical footwork research during table tennis performance has been the subject of much interest players and exercise scientists. The purpose of this study was to investigate the lower limb kinetic characteristics of the chasse step and one step footwork during stroke play using traditional discrete analysis and one-dimensional statistical parameter mapping. Methods Twelve national level 1 table tennis players (Height: 172 ± 3.80 cm, Weight: 69 ± 6.22 kg, Age: 22 ± 1.66 years, Experience: 11 ± 1.71 year) from Ningbo University volunteered to participate in the study. The kinetic data of the dominant leg during the chasse step and one step backward phase (BP) and forward phase (FP) was recorded by instrumented insole systems and a force platform. Paired sample T tests were used to analyze maximum plantar force, peak pressure of each plantar region, the force time integral and the pressure time integral. For SPM analysis, the plantar force time series curves were marked as a 100% process. A paired-samples T-test in MATLAB was used to analyze differences in plantar force. Results One step produced a greater plantar force than the chasse step during 6.92–11.22% BP (P = 0.039). The chasse step produced a greater plantar force than one step during 53.47–99.01% BP (P < 0.001). During the FP, the chasse step showed a greater plantar force than the one step in 21.06–84.06% (P < 0.001). The one step produced a higher maximum plantar force in the BP (P = 0.032) and a lower maximum plantar force in the FP (P = 0) compared with the chasse step. The one step produced greater peak pressure in the medial rearfoot (P = 0) , lateral rearfoot (P = 0) and lateral forefoot (P = 0.042) regions than the chasse step during BP. In FP, the chasse step showed a greater peak pressure in the Toe (P = 0) than the one step. The one step had a lower force time integral (P = 0) and greater pressure time integral (P = 0) than the chasse step in BP, and the chasse step produced a greater force time integral (P = 0) and pressure time integral (P = 0.001) than the one step in the FP. Conclusion The findings indicate that athletes can enhance plantarflexion function resulting in greater weight transfer, facilitating a greater momentum during the 21.06–84.06% of FP. This is in addition to reducing the load on the dominant leg during landing by utilizing a buffering strategy. Further to this, consideration is needed to enhance the cushioning capacity of the sole heel and the stiffness of the toe area.


2014 ◽  
Vol 104 (2) ◽  
pp. 125-133 ◽  
Author(s):  
Jeanna M. Fascione ◽  
Ryan T. Crews ◽  
James S. Wrobel

Background The use of foot measurements to classify morphology and interpret foot function remains one of the focal concepts of lower-extremity biomechanics. However, only 27% to 55% of midfoot variance in foot pressures has been determined in the most comprehensive models. We investigated whether dynamic walking footprint measurements are associated with inter-individual foot loading variability. Methods Thirty individuals (15 men and 15 women; mean ± SD age, 27.17 ± 2.21 years) walked at a self-selected speed over an electronic pedography platform using the midgait technique. Kinetic variables (contact time, peak pressure, pressure-time integral, and force-time integral) were collected for six masked regions. Footprints were digitized for area and linear boundaries using digital photo planimetry software. Six footprint measurements were determined: contact area, footprint index, arch index, truncated arch index, Chippaux-Smirak index, and Staheli index. Linear regression analysis with a Bonferroni adjustment was performed to determine the association between the footprint measurements and each of the kinetic variables. Results The findings demonstrate that a relationship exists between increased midfoot contact and increased kinetic values in respective locations. Many of these variables produced large effect sizes while describing 38% to 71% of the common variance of select plantar kinetic variables in the medial midfoot region. In addition, larger footprints were associated with larger kinetic values at the medial heel region and both masked forefoot regions. Conclusions Dynamic footprint measurements are associated with dynamic plantar loading kinetics, with emphasis on the midfoot region.


2009 ◽  
Vol 12 (4) ◽  
pp. 81-85
Author(s):  
Sergey Valentinovich Gorokhov ◽  
Oleg Viktorovich Udovichenko ◽  
Gagik Radikovich Galstyan ◽  
Evgeny Nikolaevich Afanas'ev ◽  
Galina Yur'evna Volkova

Aim. To assess efficiency of orthopedic footwear for diabetic patients by in-shoe computed pedobarography. Materials and methods. The study included 20 women with type 1 or 2 diabetes mellitus, diabetic polyneuropathy and/or angiopathy combined withmoderate foot deformity. In-shoe computed pedobarography (F-scan, Tekscan, USA) was used to study pressure distribution patterns in ordinary footwearidentical for each patient (control) and in special shoes shaped to the foot of individual patients. Results. Median peak pressure in orthopedic footwear was reduced by 29% compared with control value. The number of patients with overloadedfoot regions decreased from 75 to 35%, p=0,025. The change of integral load indices for clinically significant foot regions was estimated at -34%(-67%; -17%) for pressure-time integral and -26% (-65%; +7%) for force-time integral (p


2011 ◽  
Vol 32 (11) ◽  
pp. 1075-1080 ◽  
Author(s):  
Heather Schmidt ◽  
Lindsay D. Sauer ◽  
Sae Yong Lee ◽  
Susan Saliba ◽  
Jay Hertel

Background: Previous plantar pressure research found increased loads and slower loading response on the lateral aspect of the foot during gait with chronic ankle instability compared to healthy controls. The studies had subjects walking barefoot over a pressure mat and results have not been confirmed with an in-shoe plantar pressure system. Our purpose was to report in-shoe plantar pressure measures for chronic ankle instability subjects compared to healthy controls. Methods: Forty-nine subjects volunteered (25 healthy controls, 24 chronic ankle instability) for this case-control study. Subjects jogged continuously on a treadmill at 2.68 m/s (6.0 mph) while three trials of ten consecutive steps were recorded. Peak pressure, time-to-peak pressure, pressure-time integral, maximum force, time-to-maximum force, and force-time integral were assessed in nine regions of the foot with the Pedar-x in-shoe plantar pressure system (Novel, Munich, Germany). Results: Chronic ankle instability subjects demonstrated a slower loading response in the lateral rearfoot indicated by a longer time-to-peak pressure (16.5% ± 10.1, p = 0.001) and time-to-maximum force (16.8% ± 11.3, p = 0.001) compared to controls (6.5% ± 3.7 and 6.6% ± 5.5, respectively). In the lateral midfoot, ankle instability subjects demonstrated significantly greater maximum force (318.8 N ± 174.5, p = 0.008) and peak pressure (211.4 kPa ± 57.7, p = 0.008) compared to controls (191.6 N ± 74.5 and 161.3 kPa ± 54.7). Additionally, ankle instability subjects demonstrated significantly higher force-time integral (44.1 N/s ± 27.3, p = 0.005) and pressure-time integral (35.0 kPa/s ± 12.0, p = 0.005) compared to controls (23.3 N/s ± 10.9 and 24.5 kPa/s ± 9.5). In the lateral forefoot, ankle instability subjects demonstrated significantly greater maximum force (239.9N ± 81.2, p = 0.004), force-time integral (37.0 N/s ± 14.9, p = 0.003), and time-to-peak pressure (51.1% ± 10.9, p = 0.007) compared to controls (170.6 N ± 49.3, 24.3 N/s ± 7.2 and 43.8% ± 4.3). Conclusion: Using an in-shoe plantar pressure system, chronic ankle instability subjects had greater plantar pressures and forces in the lateral foot compared to controls during jogging. Clinical Relevance: These findings may have implications in the etiology and treatment of chronic ankle instability. Level of Evidence: III, Retrospective Case Control Study


1992 ◽  
Vol 82 (10) ◽  
pp. 507-513 ◽  
Author(s):  
PB Sanfilippo ◽  
RM Stess ◽  
KM Moss

A comparison of five commonly used insole materials (Spenco, PPT, Plastazote, Nickelplast, and Pelite) was made to evaluate their effectiveness in reducing plantar vertical pressures on human subjects during walking. With the use of the EMED-SF pedograph force plate system, dynamic measures of vertical force, force-time integral, peak plantar pressure, pressure-time integral, and area of foot-to-ground contact were compared with the force plate covered with each of the insole materials and without any interface material.


1996 ◽  
Vol 17 (4) ◽  
pp. 204-209 ◽  
Author(s):  
T. W. Kernozek ◽  
E. E. LaMott ◽  
M. J. Dancisak

We examined the reliability of in-shoe foot pressure measurement using the Pedar in-shoe pressure measurement system for 25 participants walking at treadmill speeds of 0.89, 1.12, and 1.34 meters/sec. The measurement system uses EMED insoles, which consist of 99 capacitive sensors, sampled at 50 Hz. Data were collected for 20 seconds at two separate times while participants walked at each gait speed. Differences in some of the loading variables across speed relative to the total foot and across the different anatomical regions were detected. Different anatomical regions of the foot were loaded differently with variations in walking speed. The results indicated the need to control speed when evaluating loading parameters using in-shoe pressure measurement techniques. Coefficients of reliability were calculated. Variables such as peak force for the total foot required two steps to achieve a coefficient of reliability of 0.98. To achieve excellent reliability (>0.90) in the peak force, force time integral, peak pressure, and pressure time integral across the total foot and the seven regions, a maximum of eight steps was needed. In general, timing variables, such as the instant of peak force and the instant of peak pressure, tended to be the least reliable measures.


1996 ◽  
Vol 17 (11) ◽  
pp. 662-666 ◽  
Author(s):  
Meir Nyska ◽  
Chris McCabe ◽  
Keith Linge ◽  
Leslie Klenerman

The effect of walking with high-heel shoes on plantar foot pressure distribution was investigated. Ten normal women walking in shoes with low heels were compared to women walking in high-heel shoes. It was shown that high-heel shoes increased the load on the forefoot and relieved it on the hindfoot. The load passed toward the medial forefoot and the hallux. The lateral side of the forefoot showed a decrease in contact area, reduced forces, and peak pressures. The medial side of the forefoot had a higher force-time and pressure-time integral. It is suggested that these higher loads on the medial forefoot may aggravate symptoms in patients with hallux valgus deformity.


2011 ◽  
Vol 11 (05) ◽  
pp. 1071-1083 ◽  
Author(s):  
SU-YA LEE ◽  
CHEN-YU CHOU ◽  
YI-YOU HOU ◽  
YU-LIN WANG ◽  
CHICH-HAUNG YANG ◽  
...  

The aim of this study was to investigate the foot plantar pressure distribution and the effect of different step width during walking. Methods: Nineteen female volunteers who aged 18~30 years old and with no history of lower extremity injury were considered. Subjects walked at a pre-determined set speed with varied step width (5 cm, 10 cm, and 20 cm) for three trials at each step width. This study used an in-sole plantar pressure measurement system to collect the peak pressure, maximum ground reaction force, pressure–time integral, and force–time integral data of eight different foot regions. Results: The data revealed that the peak plantar foot pressure on the medial arch increased with wider step width (p < 0.05). In contrast, maximum ground reaction force, peak plantar pressure, pressure–time integral, and force–time integral on the lateral arch and lateral side of the metatarsals decreased with wider step width (p < 0.05). Conclusion: The results of this study revealed that smaller step width during walking result in decreasing the pressure on the medial arch of the foot. It may have the relieving effect for clients with pes planus and it can be a reference for rehabilitation clinicians while treating the above-mentioned subjects.


2017 ◽  
Vol 09 (05) ◽  
pp. 1750064 ◽  
Author(s):  
A. Van Hirtum ◽  
X. Pelorson

Experiments on mechanical deformable vocal folds replicas are important in physical studies of human voice production to understand the underlying fluid–structure interaction. At current date, most experiments are performed for constant initial conditions with respect to structural as well as geometrical features. Varying those conditions requires manual intervention, which might affect reproducibility and hence the quality of experimental results. In this work, a setup is described which allows setting elastic and geometrical initial conditions in an automated way for a deformable vocal fold replica. High-speed imaging is integrated in the setup in order to decorrelate elastic and geometrical features. This way, reproducible, accurate and systematic measurements can be performed for prescribed initial conditions of glottal area, mean upstream pressure and vocal fold elasticity. Moreover, quantification of geometrical features during auto-oscillation is shown to contribute to the experimental characterization and understanding.


Sign in / Sign up

Export Citation Format

Share Document