scholarly journals Exact Scan Patterns of Rotational Risley Prisms Obtained with a Graphical Method: Multi-Parameter Analysis and Design

2021 ◽  
Vol 11 (18) ◽  
pp. 8451
Author(s):  
Virgil-Florin Duma ◽  
Alexandru-Lucian Dimb

Rotational Risley prisms are one of the fastest two-dimensional (2D) optomechanical scanning systems. Their drawback is the strong non-linearity of the scan patterns they produce, in contrast to the most common (but slower) raster scanning modalities of 2D dual axis galvanometer scanners (GSs) or Micro-Electro-Mechanical Systems (MEMS) with oscillatory mirrors. The aim of this work is to develop a graphical method, which, to our knowledge, we have introduced to determine and characterize, using a commercially-available mechanical design program (for example CATIA V5R20 (Dassault Systems, Paris, France)) to simulate the exact scan patterns of rotational Risley prisms. Both the maximum and minimum angular and linear deviations of this type of scanner are deduced theoretically to characterize the outer diameter/Field-of-View (FOV) and the inner diameter (of the blind zone) of its ring-shaped patterns, respectively. This multi-parameter analysis is performed in correlation with the shape of the scan patterns, considering the four possible configurations of laser scanners with a pair of rotational Risley prisms, as well as all their parameters: prisms angles, refractive indexes, rotational speeds, distance between the two prisms, and the distance from the system to the scanned plane. Marshall’s synthetic parameters are also considered, i.e., the ratios of the rotational velocities and of the angles of the prisms. Rules-of-thumb for designing this optomechanical scanner are extracted from this analysis, regarding both shapes and dimensions of the scan patterns to be produced. An example of experimental validation completes the mathematical analysis and the performed simulations.

2012 ◽  
Vol 214 ◽  
pp. 249-253
Author(s):  
Xiu Hua Zhang ◽  
Xue Feng Zhao ◽  
Xing Lei Zhang

Appropriate rotor material and reasonable structure should be used for increase energy-storing density of flywheel. Theoretical analysis and design to high-speed energy-storing flywheel rotor with maximum energy-storing density is studied in the paper.The ratio of inner diameter and outer diameter and structure dimensions of a given condition flywheel rim is obtained by calculating. And the interference fit of rim/hub of the flywheel is analyzed with finite element software. One efficient and reliable calculating foundation and analysis method for the structure design of the flywheel rotor is provided.


Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1145
Author(s):  
Magdalena Kal ◽  
Izabela Chojnowska-Ćwiąkała ◽  
Mateusz Winiarczyk ◽  
Monika Jasielska ◽  
Jerzy Mackiewicz

Background: The aim of this study was to evaluate the quantitative morphological changes in lamellar macular holes (LMHs) based on SD-OCT examinations and to assess the correlations among minimal retinal thickness (MRT), reading vision (RV), and best corrected visual acuity (BCVA) over a 36-month follow-up period. Methods: A group of 40 patients (44 eyes) with LMH was evaluated, with an average age of 69.87 (SD = 10.14). The quantitative parameters monitored in the follow-up period (at 0, 3, 6, 12, 18, 24, 30, and 36 months) were tested for normality of distribution by Shapiro–Wilk and Kolmogorov–Smirnov tests. Results: The RV and BCVA values were stable, and no significant changes were found at any of the check-ups during the 36-month follow-up period (BCVA p = 0.435 and RV p = 0.0999). The analysis of individual quantitative LMH parameters during the 36-month follow-up period did not demonstrate statistically significant differences: MRT (p = 0.461), Max RT temporal (p = 0.051), Max RT nasal (p = 0.364), inner diameter (ID) (p = 0.089), and outer diameter (OD) (p = 0.985). Conclusions: The observations at 0, 6, 12, 18, 24, 30, and 36 months revealed moderate and significant correlations between RV and MRT. No significant correlation between BCVA and MRT was observed.


Author(s):  
Ajay Kumar Kaviti ◽  
Akkala Siva Ram ◽  
Amit Kumar Thakur

In this experimental study, permanent magnets with three different sizes (M-1: 32 mm inner diameter, 70 mm outer diameter and 15 mm thick, M-2: 25 mm inner diameter, 60 mm outer diameter and 10 mm thick, M-3: 22 mm inner diameter, 45 mm outer diameter and 9 mm thick) are fully submerged in the single-slope glass solar still. The performance of magnetic solar stills (MSS) with three different sizes at 2 cm depth water to ensure that magnets are fully submerged is compared with conventional solar still (CSS) at the location 17.3850°N, 78.4867°E. Tiwari model is adapted to calculate the heat transfer coefficients (HTC), internal and exergy efficiencies. MSS with M-1, M-2 and M-3 significantly enhanced the convective, radiative, and evaporative heat transfer rate for the 2 cm depth of water. This is due to the desired magnetic treatment of water, which reduces the surface tension and increases the hydrogen bonds. The MSS's total internal HTC, instantaneous efficiencies led CSS by 25.52%, 28.8%, respectively, with M-1. Having various magnetic fields due to different magnets sizes increases MSS's exergetic efficiency by 33.61% with M-1, 33.76% with M-2, and 42.25% with M-3. Cumulative yield output for MSS with M-1, M-2, and M-3 is 21.66%, 17.64%, 15.78% higher than CSS. The use of permanent magnets of different sizes in the MSS is a viable, economical and straight forward technique to enhance productivity.


1995 ◽  
Vol 4 (6) ◽  
pp. 597-608 ◽  
Author(s):  
Jiro Hirai ◽  
Takehisa Matsuda

A tubular, hierarchically structured hybrid vascular tissue composed of vascular cells and collagen was prepared. First, a cold mixed solution of bovine aortic smooth muscle cells (SMCs) and Type I collagen was poured into a tubular glass mold composed of a mandrel and a sheath (example of dimensions: inner diameter, 1.5 mm; outer diameter, 7 mm; length, 7 cm). Upon incubation at 37°C, an SMC-incorporated collagenous gel was formed. After the sheath was removed, the resulting fragile tissue, when cultured in medium, thinned in a time-dependent manner to form an opaque, dense tissue. Higher SMC seeding density and lower initial collagen concentration induced more rapid and prominent shrinkage of the tissue. Morphologic investigation showed that over time, bipolarly elongated SMCs and collagen fiber bundles became positioned around the mandrel. Both components became circumferentially oriented. When the mandrel was removed, a tubular hybrid medial tissue was formed. A hybrid vascular tissue with a hierarchical structure was constructed by seeding endothelial cells onto the inner surface of the hybrid medial tissue. Prepared tissues tolerated luminal pressures as great as 100 mmHg and mechanical stress applied during an anastomotic procedure. This method allowed us to prepare a tubular hybrid medial tissue of predetermined size (inner diameter, wail thickness, and length) by selecting appropriate mold design, initial collagen concentration, and SMC seeding density. Such hybrid vascular tissues may provide physiological functions when implanted into the venous system.


Author(s):  
G. K. Ananthasuresh ◽  
Sridhar Kota

Abstract A great majority of the available micro devices and systems use compliant (or flexible) structures and mechanisms. This trend in design takes advantage of micromachining techniques while satisfying the constraints imposed by them. By citing relevant literature, this article briefly notes the influence of compliance on the mechanical design and analysis of Micro-Electro-Mechanical Systems (MEMS).


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.


2019 ◽  
Vol 98 (4) ◽  
pp. 455-460
Author(s):  
Lyudmila V. Akhaltseva ◽  
V. S. Zhurkov ◽  
L. P. Sycheva ◽  
O. N. Savostikova ◽  
A. V. Alekseeva

Introduction. One of the important steps in assessing the nanoparticles (NP) safety is the analysis of mutagenic activity, including the evaluation of gene, chromosomal, and genomic mutations. Material and methods. The purpose of this investigation is to study the ability of different NP aqueus suspensions and the same compounds in microforms to unduce gene mutations in Salmonella/microsome test (Ames test). Anatase titanium dioxide NP coated with simethicone (33.16 ± 16.7 nm, 5-50000 μg/ml), magnetite NP coated with silicate (10 nm, 0.92-575 μg/ml), silver NP coated with аrabian gum (14 ± 0.2 nm, 5-50000 μg/ml), aluminum hydroxide nanofibres (50-70 nm, 24-3000 μg/ml) and multi-walled carbon nanotubes (Taunit MWСNTs, outer diameter 15-40 nm, inner diameter 3-8 nm, length 2 and more microns, 5-50000 μg/ml). In parallel, the mutagenic activity of equivalent microparticles was evaluated in experiments. Ames test (Salmonella/microsomes) registers gene mutations induced by a different mechanism of action, in the variant with preincubation. A set of Salmonella typhimurium indicator strains: TA 100 (base pair substitution mutations), TA 98 and TA 97 (mutations of the frameshift type of the genetic code) were used. Using addition the S9 microsomal activating mixture during the experiment makes it is possible to determine the effect not only of the substances themselves, but also of their metabolites. Conclusion. The investigated nanomaterials as well as their micro analogs in the studied dose range did not induce gene mutations in the Ames test both in presence and absence microsomal activating mixture.


2006 ◽  
Vol 21 (2) ◽  
pp. 529-534 ◽  
Author(s):  
Jun-ichi Minato ◽  
Kun'ichi Miyazawa

Crystalline microtubes (inner diameter 240–2100 nm) consisting of C60 fullerene molecules were prepared in the mixture of C60-saturated pyridine and isopropyl alcohol kept at 0 °C. Characterization by transmission electron microscopy showed a linear relationship between the outer diameter and the inner diameter for the C60 fullerene tubes. Optical observations suggested that the specimens already had tubular structure when they were grown in the solution. Deposition of guest crystals inside the C60 fullerene tubes was performed by the following procedure: (i) ultrasonic pulverization to obtain the C60 fullerene tubes with open ends, (ii) absorption of methyl alcohol solution of KBr into the tubes by the capillary attraction, and (iii) evaporation of methyl alcohol to precipitate KBr inside the tubes. Columnar KBr crystals were then obtained by dissolving the fullerene tube walls in toluene.


Sign in / Sign up

Export Citation Format

Share Document