scholarly journals Computational Investigation for Biomechanical Characteristics of Lumbar Spine with Various Porous Ti–6Al–4V Implant Systems

2021 ◽  
Vol 11 (17) ◽  
pp. 8023
Author(s):  
Chan-Hee Song ◽  
Jun-Sung Park ◽  
Byung-Wan Choi ◽  
Jung Sub Lee ◽  
Chi-Seung Lee

(1) Background: Metallic materials are predominantly used for spinal implants, and they can damage adjacent bones and intervertebral discs (IVDs) owing to their high elastic moduli. Consequently, there is a possibility that serious complications, such as kyphosis, may occur as the sequelae progresses. In this study, the behavior of the lumbar spine and implant system was evaluated using the finite element (FE) method, by applying the porous structure to the spinal implants to resolve the problem of metal spinal implants. (2) Methods: An FE model was developed for lumbar 3–5, and it was assumed that, owing to disease occurrence, spinal implants were placed in lumbar 3–4. Currently, Ti–6Al–4V is the most commonly used material for spinal implants. The shape of the porous structure was set in the form of a diamond, and porosity was varied over nine values ranging from 0 to 81%. Finally, equivalent material properties of the porous structure were derived using the Ramberg–Osgood formula, with reference to experimental study. (3) Results: The range of motion was increased, and the equivalent stress of adjacent IVD, and adjacent bone stress of the pedicle screw and spinal cage, decreased with increasing porosity of the spinal implants. As the porosity decreased, the safety factor exhibited a tendency to decrease rapidly. (4) Conclusion: Motor capacity of the spine was improved, and the equivalent stress of the spinal tissues decreased with the increasing porosity of the spinal implants. Therefore, in the future, porous structures can significantly contribute to the improvement of implants through continuous complementary research.

Author(s):  
Nadja Wilmanns ◽  
Agnes Beckmann ◽  
Luis Fernando Nicolini ◽  
Christian Herren ◽  
Rolf Sobottke ◽  
...  

Abstract Lumbar Lordotic correction (LLC), the gold standard treatment for Sagittal Spinal malalignment (SMA), and its effect on sagittal balance have been critically discussed in recent studies. This paper assesses the biomechanical response of the spinal components to LLC as an additional factor for the evaluation of LLC. Human lumbar spines (L2L5) were loaded with combined bending moments in Flexion (Flex)/Extension (Ex) or Lateral Bending (LatBend) and Axial Rotation (AxRot) in a physiological environment. We examined the dependency of AxRot range of motion (RoM) on the applied bending moment. The results were used to validate a Finite Element (FE) model of the lumbar spine. With this model, the biomechanical response of the intervertebral discs (IVD) and facet joints under daily motion was studied for different sagittal spinal alignment (SA) postures, simulated by a motion in Flex/Ex direction. Applied bending moments decreased AxRot RoM significantly (all P<0.001). A stronger decline of AxRot RoM for Ex than for Flex direction was observed (all P<0.0001). Our simulated results largely agreed with the experimental data (all R2>0.79). During daily motion, the IVD was loaded higher with increasing lumbar lordosis (LL) for all evaluated values at L2L3 and L3L4 and posterior Annulus Stress (AS) at L4L5 (all P<0.0476). The results of this study indicate that LLC with large extensions of LL may not always be advantageous regarding the biomechanical loading of the IVD. This finding may be used to improve the planning process of LLC treatments.


2014 ◽  
Vol 2014 ◽  
pp. 1-15 ◽  
Author(s):  
J. Cegoñino ◽  
V. Moramarco ◽  
A. Calvo-Echenique ◽  
C. Pappalettere ◽  
A. Pérez del Palomar

The study of the mechanical properties of the annulus fibrosus of the intervertebral discs is significant to the study on the diseases of lumbar intervertebral discs in terms of both theoretical modelling and clinical application value. The annulus fibrosus tissue of the human intervertebral disc (IVD) has a very distinctive structure and behaviour. It consists of a solid porous matrix, saturated with water, which mainly contains proteoglycan and collagen fibres network. In this work a mathematical model for a fibred reinforced material including the osmotic pressure contribution was developed. This behaviour was implemented in a finite element (FE) model and numerical characterization and validation, based on experimental results, were carried out for the normal annulus tissue. The characterization of the model for a degenerated annulus was performed, and this was capable of reproducing the increase of stiffness and the reduction of its nonlinear material response and of its hydrophilic nature. Finally, this model was used to reproduce the degeneration of the L4L5 disc in a complete finite element lumbar spine model proving that a single level degeneration modifies the motion patterns and the loading of the segments above and below the degenerated disc.


2004 ◽  
Vol 08 (02n03) ◽  
pp. 87-99 ◽  
Author(s):  
Li-Xin Guo ◽  
Ee-Chon Teo ◽  
Tian-Xia Qiu

In this study, the biomechanical roles of disc nucleus and ligaments of human lower thoracic spine (T10–T12) under different loads were investigated using finite element (FE) method. The T10–T12 FE model was developed and validated against the published results. The FE model was then modified accordingly to simulate the injured conditions of nucleus, ligaments and facets and loaded under different configurations to analyze the segmental gross responses and the stress distribution around the annulus circumference. The high first-principal stress of annulus at the posterolateral region has an important role on the disc annulus's tear and a flexion moment causes a high first-principal stress at posterolateral region, despite of the existence of ligaments. The study also shows that decompression in intervertebral discs can reduce the dilatation of annulus tears by 18% around the posterolateral regions of disc annulus. The disc nucleus and the posterior ligaments have important roles in resisting compression and flexion loads, respectively. The investigations in this paper not only supplement experimental research but are also helpful in the understandings of biomechanics of lower thoracic spine.


Author(s):  
Guobiao Ji ◽  
Liang Cheng ◽  
Shaohua Fei ◽  
Jiangxiong Li ◽  
Yinglin Ke

Through-thickness reinforcement is a promising solution to the problem of delamination susceptibility in laminated composites. Modeling Z-pin–prepreg interaction is essential for accurate robotics-assisted Z-pin insertion. In this paper, a novel Z-pin insertion force model combining the classical cohesive finite element (FE) method with a dynamic analytical fracture mechanics model is proposed. The velocity-dependent cohesive elements, in which the fracture toughness is provided by the analytical model, are implemented in Z-pin insertion FE model to predict the crack initiation and propagation. Then Z-pin insertion experiments are performed on prepreg sample with metallic Z-pins at different velocities to identify the analytical model parameters and validate the simulation predictions offered by the model. Dynamics of Z-pin interaction with inhomogeneous prepreg is described and the effects of insertion velocity on prepreg contact force are studied. Results show that the force model agrees well with experiments and the fracture toughness rises with the increasing Z-pin insertion velocity.


2021 ◽  
pp. 002199832110335
Author(s):  
Osman Kartav ◽  
Serkan Kangal ◽  
Kutay Yücetürk ◽  
Metin Tanoğlu ◽  
Engin Aktaş ◽  
...  

In this study, composite overwrapped pressure vessels (COPVs) for high-pressure hydrogen storage were designed, modeled by finite element (FE) method, manufactured by filament winding technique and tested for burst pressure. Aluminum 6061-T6 was selected as a metallic liner material. Epoxy impregnated carbon filaments were overwrapped over the liner with a winding angle of ±14° to obtain fully overwrapped composite reinforced vessels with non-identical front and back dome layers. The COPVs were loaded with increasing internal pressure up to the burst pressure level. During loading, deformation of the vessels was measured locally with strain gauges. The mechanical performances of COPVs designed with various number of helical, hoop and doily layers were investigated by both experimental and numerical methods. In numerical method, FE analysis containing a simple progressive damage model available in ANSYS software package for the composite section was performed. The results revealed that the FE model provides a good correlation as compared to experimental strain results for the developed COPVs. The burst pressure test results showed that integration of doily layers to the filament winding process resulted with an improvement of the COPVs performance.


2019 ◽  
Vol 28 ◽  
pp. 096369351987741
Author(s):  
Gyula Szabó ◽  
Károly Váradi

The aim of this study is to investigate the global buckling of a relatively long composite cord–rubber tube subjected to axial compression and its cross-sectional instability due to bending by a macromechanical nonlinear finite element (FE) model (nonlinear buckling analysis). Composite reinforcement layers are modelled as transversely isotropic ones, while elastomer liners are described by a hyperelastic material model that assumes incompressibility. Force–displacement, equivalent strain, equivalent stress results along with oblateness and curvature results for the complete process have been presented. It is justified that bending leads to ovalization of the cross section and results in a loss of the load-carrying capacity of the tube. Strain states in reinforcement layers have been presented, which imply that the probable failure modes of the reinforcement layers are both delamination and yarn-matrix debonding. There is a significant increase in strains due to cross-sectional instability, which proves that the effect of cross-sectional instability on material behaviour of the tube is crucial. A parametric analysis has been performed to investigate the effect of the member slenderness ratio on cross-sectional instability of the composite tube. It shows that Brazier force is inversely proportional to the slenderness ratio. It further shows that higher oblateness parameters occur in case of a lower slenderness ratio and that cross-sectional instability takes place at a lower dimensionless displacement in case of a lower slenderness ratio. FE results have been validated by a compression/bending test experiment conducted on a tensile test machine.


Metals ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1090
Author(s):  
Bai-Hung Huang ◽  
Yi-Jung Lu ◽  
Wen-Chien Lan ◽  
Muhammad Ruslin ◽  
Hung-Yang Lin ◽  
...  

The effects of anodized titanium (Ti) with a potential hydrogen fluoride (HF) acid pretreatment through cathodization on the formation of nano-porous Ti dioxide (TiO2) layer were characterized using field-emission scanning electron microscopy, grazing incidence X-ray diffractometer, and contact angle goniometer. The biocompatibility was determined by 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide (MTT) test. Analytical results found that a well-aligned nano-porous structure was formed on the anodized Ti surface with HF pretreatment concentration above 0.5%. Microstructure of the nano-porous Ti dioxide surface generated by anodization with HF pretreatment was composed of anatase and rutile phases, while the anodized Ti sample with HF pretreatment concentration of 0.5% presented excellent hydrophilicity surface. An in-vitro biocompatibility also indicated that osteoblast cells grown on the surface of the anodized Ti sample with HF pretreatment increased with the increase of culture time. The filopodia of osteoblast cells not only adhered flat, but also tightly grabbed the nano-porous structure for promoting cell adhesion and proliferation. Therefore, the anodized Ti with HF pretreatment can form a functionalized surface with great biocompatibility for biomedical applications, particularly for dental implants.


Neurosurgery ◽  
1985 ◽  
Vol 16 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Steven L. Kanter ◽  
William A. Friedman

Abstract Percutaneous discectomy is a viable alternative in the treatment of herniated intervertebral discs of the lumbar spine. Anatomical analysis of the retroperitoneal surgical path utilizing computed tomography suggests that the risk of vascular injury is negligible at the L-4, L-5 level, but substantial at the L-5, S-1 level. In addition, one-third of patients otherwise suitable for percutaneous discectomy have segments of bowel obstructing the surgical path. Obtaining an abdominal computed tomographic scan with the patient in the surgical position seems to be a valuable screening technique in the evaluation of candidates for this procedure.


Neurosurgery ◽  
1984 ◽  
Vol 14 (3) ◽  
pp. 350-352 ◽  
Author(s):  
J. C. Angtuaco Edgardo ◽  
C. Holder John ◽  
C. Boop Warren ◽  
F. Binet Eugene

Abstract Thin section, high resolution computed tomographic (CT) scans of the lumbar spine produce images that can show herniated intervertebral discs without intravenous or intrathecal contrast enhancement. With this technique, the diagnosis of posterolateral and midline herniation has been greatly facilitated. This communication reports the use of CT discography in the preoperative evaluation of two patients who were shown at discography and proven at operation to have extreme lateral disc herniations.


2017 ◽  
Vol 14 (130) ◽  
pp. 20170202 ◽  
Author(s):  
Joseph Libby ◽  
Arsalan Marghoub ◽  
David Johnson ◽  
Roman H. Khonsari ◽  
Michael J. Fagan ◽  
...  

During the first year of life, the brain grows rapidly and the neurocranium increases to about 65% of its adult size. Our understanding of the relationship between the biomechanical forces, especially from the growing brain, the craniofacial soft tissue structures and the individual bone plates of the skull vault is still limited. This basic knowledge could help in the future planning of craniofacial surgical operations. The aim of this study was to develop a validated computational model of skull growth, based on the finite-element (FE) method, to help understand the biomechanics of skull growth. To do this, a two-step validation study was carried out. First, an in vitro physical three-dimensional printed model and an in silico FE model were created from the same micro-CT scan of an infant skull and loaded with forces from the growing brain from zero to two months of age. The results from the in vitro model validated the FE model before it was further developed to expand from 0 to 12 months of age. This second FE model was compared directly with in vivo clinical CT scans of infants without craniofacial conditions ( n = 56). The various models were compared in terms of predicted skull width, length and circumference, while the overall shape was quantified using three-dimensional distance plots. Statistical analysis yielded no significant differences between the male skull models. All size measurements from the FE model versus the in vitro physical model were within 5%, with one exception showing a 7.6% difference. The FE model and in vivo data also correlated well, with the largest percentage difference in size being 8.3%. Overall, the FE model results matched well with both the in vitro and in vivo data. With further development and model refinement, this modelling method could be used to assist in preoperative planning of craniofacial surgery procedures and could help to reduce reoperation rates.


Sign in / Sign up

Export Citation Format

Share Document