scholarly journals Performance of Solar Absorption-Subcooled Compression Hybrid Cooling System for Different Flow Rates of Hot Water

2020 ◽  
Vol 10 (3) ◽  
pp. 810 ◽  
Author(s):  
Jinfang Zhang ◽  
Zeyu Li ◽  
Yue Jing ◽  
Yongrui Xu

The solar absorption-subcooled compression hybrid cooling system (SASCHCS) is tech-economically feasible for high-rise buildings. Since such a system operates with no auxiliary heat source, the performance coupling of its absorption subsystem and solar collectors is sensitive to the variation of hot water flow rate. In this regard, the relationship of system performance and hot water flow rate is required to be clarified exactly. Therefore, this paper aims to illustrate the effect mechanism of hot water flow rate and to propose the corresponding decision criterion. The case study is based on a typical high-rise office building in subtropical Guangzhou. The daily working process of this system with different hot water flow rates is simulated and analyzed. Subsequently, the useful heat of collectors and cooling capacity of the absorption subsystem with the hot water flow rate is discussed in detail. The results show that the SASCHCS operates with hot water temperatures ranging from 60 °C to 90 °C. The energy saving increases with the rise of hot water flow rate, but such variation tends to be flat for the excessively high flow rate. As the collector flow rate increases from 1 m3/h to 10 m3/h, the daily energy saving improves by 21% in August. Similarly, the daily energy saving increases by 37.5% as generator hot water flow rate increases from 1 m3/h to 10 m3/h. In addition, the collector flow rate of 3.6 m3/h (13.33 (kg/m2 h)) and the generator flow rate of 5.2 m3/h (19.26 (kg/m2 h)) are optimal for the annual operation, with considering power consumption of water pumps. This paper is helpful for the improvement of SASCHCS operating performance.

2020 ◽  
Vol 51 (4) ◽  
pp. 209-219
Author(s):  
Mohamed Saied Ghoname

An experiment was conducted in three commercial laying hen houses with 32-week-old hens in the summer of 2017 in a commercial farm in Gharbia Province, Egypt (31.06ºN, 31.16ºE) using an evaporative pad cooling system to determine the most suitable water flow rate for maintaining indoor air temperature within the thermal comfort zone. The experiment was conducted using three different water flow rates, i.e. 4.76, 5.65, and 6.35 L min–1.m–2, to assess the effect of different water flow rates on evaporative pad cooling system performance and determine the most suitable water flow rate for maintaining the thermal comfort zone of laying hens. The evaporative pad cooling system maintained the mean indoor air temperature below 28°C. The mean indoor air relative humidity during the experimental period ranged from 72.6 to 73.8%. The 4.76 L min–1.m–2 water flow rate resulted in the highest saturation efficiency (ca. 73.75%). In contrast, the 6.35 L min–1 m–2 water flow rate resulted in the lowest saturation efficiency (70.63%). The mean cooling energy values were 69.11, 66.0, and 66.65 kwh for water flow rates of 4.76, 5.56, and 6.35 Lmin–1m–2, respectively. The highest temperature-humidity index was 27.78°C, which indicated that birds were not stressed in all treatments.


2018 ◽  
Vol 8 (10) ◽  
pp. 1973 ◽  
Author(s):  
Adnan Ploskić ◽  
Qian Wang ◽  
Sasan Sadrizadeh

The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops.


2019 ◽  
Vol 10 (1) ◽  
pp. 258 ◽  
Author(s):  
Jinfang Zhang ◽  
Zeyu Li ◽  
Hongkai Chen ◽  
Yongrui Xu

The solar absorption-subcooled compression hybrid cooling system (SASCHCS) displays outstanding advantages in high-rise buildings. Since the performance coupling of collectors and absorption subsystems is stronger due to the absence of backup heat and the effect of generator setting temperature has not been realized adequately, it is highly important to study the relationship of SASCHCS operation and the set point temperature of hot water to prevent performance deterioration by inappropriate settings. Therefore, the paper mainly deals with the effect of collector and generator setting temperature. The investigation was based on the entire cooling period of a typical high-rise office building in subtropical Guangzhou. The off-design model of hybrid systems was built at first. Subsequently, the impact mechanism of setting temperature in two hot water cycles on facility operation was analyzed. It was found that the excessive rise of collector setting temperature deteriorated the energy saving, while the appropriate improvement of generator set point temperature was beneficial for the solar cooling. Besides, global optimization by the genetic algorithm displayed that 71.6 °C for the collector setting temperature with 64.5 °C for the generator was optimal for annual operation. The paper is helpful in enhancing the operation performance of SASCHCS.


2014 ◽  
Vol 905 ◽  
pp. 263-267
Author(s):  
Shin Ku Lee ◽  
W.H. Lo ◽  
M.C. Ho ◽  
T.H. Lin

The hybrid inverse method to estimate the optimal water flow rate and surface temperature on the hot surface of the steel roller shutter with water film cooling system subjected to a fire environment is presented in this paper. The results show that the effect of the down-flowing water film flow rate on the present estimates cannot be negligible. The water-film system combined with the steel roller shutter can effectively improve the heat resistance and the temperature of the shutter slat surface can be controlled to around 100 °C. The optimal water flow rate is 110 L/min for a typical 3m x 3m steel roller shutter with water film cooling system.


2003 ◽  
Vol 125 (1) ◽  
pp. 52-58 ◽  
Author(s):  
Akihiko Hirano ◽  
Michiyoshi Yamamoto ◽  
Katsumi Sakaguchi ◽  
Tetsuo Shoji ◽  
Kunihiro Iida

The flow rate of water flowing on a steel surface is considered to be one of the important factors strongly influencing the fatigue life of the steel, because the water flow produces difference in the local environmental conditions. The effect of the water flow rate on the fatigue life of a carbon steel was thus investigated experimentally. Fatigue testing of the carbon steel was performed at 289°C for various dissolved oxygen contents (DO) of less than 0.01 and 0.05, 0.2, and 1 ppm, and at various water flow rates. Three different strain rates of 0.4, 0.01, and 0.001 %/s were used in the fatigue tests. At the strain rate of 0.4 %/s, no significant difference in fatigue life was observed under the various flow rate conditions. On the other hand, at 0.01 %/s, the fatigue life increased with increasing water flow rate under all DO conditions, such that the fatigue life at a 7 m/s flow rate was about three times longer than that at a 0.3 m/s flow rate. This increase in fatigue life is attributed to increases in the crack initiation life and small-crack propagation life. The major mechanism producing these increases is considered to be the flushing effect on locally corrosive environments at the surface of the metal and in the cracks. At the strain rate of 0.001 %/s, the environmental effect seems to be diminished at flow rates higher than 0.1 m/s. This behavior does not seem to be explained by the flushing effect alone. Based on this experimental evidence, it was concluded that the existing fatigue data obtained for carbon steel under stagnant or relatively low flow rate conditions may provide a conservative basis for fatigue life evaluation. This approach seems useful for characterizing fatigue life evaluation by expressing increasing fatigue life in terms of increasing water flow rate.


2019 ◽  
Author(s):  
MJ Booysen

Electric water heaters are responsible for a large portion of electricity consumption and water usage in the domestic sector. Smart water heaters alleviate the strain on the electricity supply grid and reduce water consumption through behavioural change, but the installation of in-line flow meters is inconvenient and expensive. A non-invasive water flow meter is proposed as an alternative. Non-invasive flow measurement is more common for high flow rates in the industrial sector than for domestic applications. Various non-invasive water measurement methods are investigated in the context of domestic hot water, and a combination of thermal- and vibration-sensing is proposed. The proposed solution uses inexpensive, easily installable, non-invasive sensors and a novel algorithm to provide the same flow measurement accuracy as existing in-line meters. The algorithm detects the beginning and end of water consumption events with an accuracy of 95.6%. Quantitative flow rate estimation was possible for flow rates greater than 5 L min⁻¹ with an accuracy of 89%, while volumetric usage estimation had an accuracy of more than 93%. The algorithm limitations were applied to field data, revealing that water consumption could be detected with an error of less than 12% within the limitations of the proposed algorithm. The paper presents a successful proof of concept for a non-invasive alternative to domestic hot water flow rate measurement.


Author(s):  
Le Minh Nhut ◽  
Tran Quang Danh

Hot water is an important factor in domestic life and industrial development. Today, the heat pump is used to produce hot water more and more popular because it has many advantages of saving energy compared to the method of producing hot water by the hot water electric heater. The main aim of this study is to evaluate of the coefficient of performance (COP) of the small hot water heat pump using refrigeration R410A and R32. The capacity of both hot water heat pump is similar, one using new refrigerant R32 and other using refrigerant R410A. These heat pumps were designed and installed at the Ho Chi Minh City University of Technology and Education to evaluate the COP for the purpose of application the new refrigerant R32 for hot water heat pump. The compressor capacity is 1 Hp, the volume of hot water storage tank is of 100 liters and is insulated with thickness of 30 mm to reduce the heat loss to invironment, the required hot water temperature at the outlet of condenser is 50 oC, and the amount of required hot water is 75 liters per batch and is controlled by float valve. The experimental results indicate that the COP of the heat pump using the new refrigerant R32 is higher than heat pump using refrigerant R410A from 9% to 15% when the experimental conditions such as ambient temperature, initial water flow rate through the condenser and the required temperature of hot water were the same. In addition, the effect of the ambient temperature, initial water temperature and water flow rate were also evaluated.


Author(s):  
Luis R. Figueroa Ibarra ◽  
J. Hugo Rodri´guez Marti´nez ◽  
Marcelino Santaba´rbara Botello

This paper details the design of a Pitot tube used for water flow rate measurements in large pipes. The paper describes first the nowadays commonly used device (simplex pitot), based on standard CTI Code ATC-105 from Cooling Tower Institute [1]. The disadvantages of the simplex pitot are pointed out, and the detailed description of the proposed device (multiport pitot) is explained. The Multiport Pitot, which design is also based on norm ATC-105, is able to perform real-time measurements. The paper also includes the results obtained from the water flow rate measurements made in the cooling system of a thermal power plant in Mexico. These measurement results were compared to simulation results obtained with a computational commercial simulation tool.


2016 ◽  
Vol 61 (4) ◽  
pp. 793-807 ◽  
Author(s):  
Nikodem Szlązak ◽  
Dariusz Obracaj ◽  
Justyna Swolkień ◽  
Kazimierz Piergies

Abstract In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.