scholarly journals Validity of the Catapult ClearSky T6 Local Positioning System for Team Sports Specific Drills, in Indoor Conditions

2018 ◽  
Vol 9 ◽  
Author(s):  
Live S. Luteberget ◽  
Matt Spencer ◽  
Matthias Gilgien
Sensors ◽  
2020 ◽  
Vol 20 (20) ◽  
pp. 5733
Author(s):  
Prisca S. Alt ◽  
Christian Baumgart ◽  
Olaf Ueberschär ◽  
Jürgen Freiwald ◽  
Matthias W. Hoppe

This study aimed to compare the validity of a local positioning system (LPS) during outdoor and indoor conditions for team sports. The impact of different filtering techniques was also investigated. Five male team sport athletes (age: 27 ± 2 years; maximum oxygen uptake: 48.4 ± 5.1 mL/min/kg) performed 10 trials on a team sport-specific circuit on an artificial turf and in a sports hall. During the circuit, athletes wore two devices of a recent 20-Hz LPS. From the reported raw and differently filtered velocity data, distances covered during different walking, jogging, and sprinting sections within the circuit were computed for which the circuit was equipped with double-light timing gates as criterion measures. The validity was determined by comparing the known and measured distances via the relative typical error of estimate (TEE). The LPS validity for measuring distances covered was good to moderate during both environments (TEE: 0.9–7.1%), whereby the outdoor validity (TEE: 0.9–6.4%) was superior than indoor validity (TEE: 1.2–7.1%). During both environments, validity outcomes of an unknown manufacturer filter were superior (TEE: 0.9–6.2%) compared to those of a standard Butterworth filter (TEE: 0.9–6.4%) and to unprocessed raw data (TEE: 1.0–7.1%). Our findings show that the evaluated LPS can be considered as a good to moderately valid tracking technology to assess running-based movement patterns in team sports during outdoor and indoor conditions. However, outdoor was superior to indoor validity, and also impacted by the applied filtering technique. Our outcomes should be considered for practical purposes like match and training analyses in team sport environments.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1465
Author(s):  
Patrick Blauberger ◽  
Robert Marzilger ◽  
Martin Lames

The aim of this study was the validation of player and ball position measurements of Kinexon’s local positioning system (LPS) in handball and football. Eight athletes conducted a sport-specific course (SSC) and small sided football games (SSG), simultaneously tracked by the LPS and an infrared camera-based motion capture system as reference system. Furthermore, football shots and handball throws were performed to evaluate ball tracking. The position root mean square error (RMSE) for player tracking was 9 cm for SSCs, the instantaneous peak speed showed a percentage deviation from the reference system of 0.7–1.7% for different exercises. The RMSE for SSGs was 8 cm. Covered distance was overestimated by 0.6% in SSCs and 1.0% in SSGs. The 2D RMSE of ball tracking was 15 cm in SSGs, 3D position errors of shot and throw impact locations were 17 cm and 21 cm. The methodology for the validation of a system’s accuracy in sports tracking requires extensive attention, especially in settings covering both, player and ball measurements. Most tracking errors for player tracking were smaller or in line with errors found for comparable systems in the literature. Ball tracking showed a larger error than player tracking. Here, the influence of the positioning of the sensor must be further reviewed. In total, the accuracy of Kinexon’s LPS has proven to represent the current state of the art for player and ball position detection in team sports.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 2896
Author(s):  
Pratham Singh ◽  
Michael Esposito ◽  
Zach Barrons ◽  
Christian A. Clermont ◽  
John Wannop ◽  
...  

One possible modality to profile gait speed and stride length includes using wearable technologies. Wearable technology using global positioning system (GPS) receivers may not be a feasible means to measure gait speed. An alternative may include a local positioning system (LPS). Considering that LPS wearables are not good at determining gait events such as heel strikes, applying sensor fusion with an inertial measurement unit (IMU) may be beneficial. Speed and stride length determined from an ultrawide bandwidth LPS equipped with an IMU were compared to video motion capture (i.e., the “gold standard”) as the criterion standard. Ninety participants performed trials at three self-selected walk, run and sprint speeds. After processing location, speed and acceleration data from the measurement systems, speed between the last five meters and stride length in the last stride of the trial were analyzed. Small biases and strong positive intraclass correlations (0.9–1.0) between the LPS and “the gold standard” were found. The significance of the study is that the LPS can be a valid method to determine speed and stride length. Variability of speed and stride length can be reduced when exploring data processing methods that can better extract speed and stride length measurements.


2005 ◽  
Vol 7 (7) ◽  
pp. 736 ◽  
Author(s):  
L. A. Lee ◽  
S. C. Soderholm ◽  
M. M. Flemmer ◽  
J. L. Hornsby-Myers

Sign in / Sign up

Export Citation Format

Share Document