scholarly journals Massive Amniotic Fluid Aspiration in a Case of Sudden Neonatal Death With Severe Hypoplasia of the Retrotrapezoid/Parafacial Respiratory Group

2019 ◽  
Vol 7 ◽  
Author(s):  
Anna M. Lavezzi ◽  
Antonella Poloniato ◽  
Rosanna Rovelli ◽  
Laura Lorioli ◽  
Gabriela Alejandra Iasi ◽  
...  
Author(s):  
Rachna Chaudhary ◽  
Vandana Dhama ◽  
Shakun Singh ◽  
Madhumita Singh

Background: Amniotic fluid assessment is an essential part of evaluation of fetus health in terms of fetal distress, meconium aspiration, IUGR, Non-reassuring fetal heart rate patterns, birth asphyxia, low birth weight, low Apgar-scores and NICU Admissions.Methods: This prospective observational study included 200 antenatal patients of term gestation of which 100 cases with AFI<8 and 100 controls with AFI ≥8 but ≤ 15 were included in study. Ultrasonography and NST were done and results of both groups compared for the presence of meconium passage, non-reactive NST, birth asphyxia, low Apgar-scores, low birth weight, NICU admissions and neonatal deaths.Results: There was increased incidence of non-reactive NST (40% vs 12%), meconium stained (33% vs 10%) in oligohydramnios group. In cases 49% of patients had vaginal delivery while in controls 78%. 51% underwent LSCS in cases while in controls 22%. Apgar score <7 was found in 7% vs 4%. Birth weight was <2.5 kg in 35% vs 13%. NICU admissions in study group was 15% vs 11%. The neonatal death was similar in both cases groups.Conclusions: Oligohydramnios affect the neonatal outcome in terms of meconium stained liquor, non-reassuring fetal heart rate, low birth weight, birth asphyxia, low Apgar-scores and NICU Admissions and neonatal death but the difference was not statistically significant. Early detection of oligohydramnios and its management may help in reduction of perinatal morbidity and decreased caesarean deliveries.


2021 ◽  
pp. 1-3
Author(s):  
Kajal Kunwar ◽  
Shanti HK Singh

Aims and objectives: Meconium stained amniotic fluid was considered a sign of fetal distress and associated with poor fetal outcome, but others considered physiological phenomena to be meconium passage through the fetus and create environmental threats to the fetus before birth. Such magnitude of different opinions was the object behind taking up this study and the aim was to find out the incidence and effect of meconium in terms of morbidity and mortality. Material and Methods: The present study was undertaken to evaluate the significance of MSAF and its fetal outcome in parturients admitted to a tertiary care hospital between June 2012 to June 2014. Detection of MSAF during delivery and follow-up of mother and baby during hospital stay was done. A total number of 100 cases were studied in each group as a prospective study. Results: The total numbers of deliveries during the study period were 850 of which 100 cases had meconium staining of AF (11.6%). Thin meconium staining was seen in 37 cases (4.35%) and Thick meconium was seen in 63 cases (7.41%). The major neonatal complication was birth asphyxia in MSG (19%) which was more in thick MSG (14%). Neonatal morbidity was more in the newborn with the thick meconium group (36.5%) compared to the thin meconium-stained group (29.7%). Early neonatal mortality was 100% associated with thick MSG. Early neonatal death was 2 in thick MSG and it was due to MAS. Stillbirth was 100% associated with thick MSG and it was 4. Whereas stillbirth in the control group was 1. Perinatal mortality was 6% in MSG that was associated with thick MSG. In the control group, it was 1%. Consistency of meconium has a direct bearing on the fetal outcome. In the thick meconium-stained group, Neonatal morbidity was (in our study group) 23 out of 63 cases. Stillbirth was 4; early neonatal death was 2 out of 63 cases. Whereas in thin MSG neonatal morbidity was 11 out of 37 cases. No stillbirth or neonatal death occurred in thin MSG. Conclusion: Immediate airway management, need for suction, and intubation should be guided by the state of the newborn rather than the presence of meconium. Timely diagnosis and management of amniotic fluid stained with meconium can enhance the fetal outcome. The authors of the current study conclude that MSAF adversely affects the fetal outcome mainly by thick meconium.


Author(s):  
Smita Tyagi ◽  
Rajesh Kumar Agarwal ◽  
Manish Agarwal ◽  
Manika Kapoor ◽  
Sakshi Tiwari

Background: The objective of this study was to estimate the incidence of vertical transmission COVID-19 by RT-PCR.Methods: In this hospital based prospective study, all COVID-19 positive pregnant women admitted in COVID ward in Muzaffarnagar medical college and hospital from April 2020 to January 2021 were included. A detailed history and examination was done and all routine investigations were done as per protocol. Samples were taken from amniotic fluid during vaginal delivery or caesarean section and collected in viral transport medium. Sample were also collected as nasal and oropharyngeal swab from neonate immediately after birth and sent for COVID 19 RT-PCR.Results: Out of total 50 cases; 43 (86%) neonates were delivered via LSCS and 7 (14%) by normal delivery, out of these 41 (82%) neonates were normal; 4 (8%) were IUGR, 2 (4%) were IUD, 2 (4%) were pre-term and 1 (2%) neonatal death. All 50 amniotic fluid as well as nasal and oropharyngeal samples of all neonates were negative by RT-PCR.Conclusions: Low vertical transmission may be due to the fact that antibodies are produced by mother that crosses the placenta and saves the fetus or there are highly specific immunological mediators in the placenta that do not allow the infection to pass to the fetus.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Delia Horn ◽  
Erika Edwards ◽  
Renny Ssembatya ◽  
Kristen DeStigter ◽  
Anne Dougherty ◽  
...  

Abstract Background Although the use of prenatal ultrasound services has increased in low- income and lower middle-income countries, there has not been a concurrent improvement in perinatal mortality. It remains unknown whether individual ultrasound findings in this setting are associated with neonatal death or the need for resuscitation at delivery. If associations are identified by ultrasound, they could be used to inform the birth attendant and counsel the family regarding risk, potentially altering delivery preparedness in order to reduce neonatal mortality. Methods This was a secondary analysis of data collected from a prospective cohort. Data was gathered at Nawanyago Health Centre III in Kamuli District, Uganda. Participants included pregnant women who received second and third trimester prenatal ultrasound scans and delivered at that center between July 2010 and August 2018. All ultrasounds were performed at Nawanyago and deliveries were attended solely by midwives or nurses. Predictor variables included the following ultrasound findings: fetal number, fetal presentation, and amniotic fluid volume. The primary outcome was bag-mask ventilation (BMV) of the neonate at delivery. The secondary outcome was stillbirth or neonatal death in the delivery room. Results Primary outcome data was available for 1105 infants and secondary outcome data was available for 1098 infants. A total of 33 infants received BMV at delivery. The odds of receiving BMV at delivery was significantly increased if amniotic fluid volume was abnormal (OR 4.2, CI 1.2-14.9) and there were increased odds for multiple gestation (OR 1.9, CI 0.7-5.4) and for non-vertex fetal presentation (OR 1.4, CI 0.6-3.2) that were not statistically significant. Stillbirth or neonatal death in the delivery room was diagnosed for 20 infants. Multiple gestation (OR 4.7, CI 1.6-14.2) and abnormal amniotic fluid volume (OR 4.8, CI 1.0-22.1) increased the odds of stillbirth or neonatal death in the delivery room, though only multiple gestation was statistically significant. Conclusion Common findings that are easily identifiable on ultrasound in low- and lower middle-income countries are associated with adverse perinatal outcomes. Education could lead to improved delivery preparedness, with the potential to reduce perinatal mortality. This was a preliminary study; larger prospective studies are needed to confirm these findings.


1995 ◽  
Vol 3 (2) ◽  
pp. 79-81 ◽  
Author(s):  
William J. Watson ◽  
Sami Awadallah ◽  
Mary Jo Jaqua

Background: Although maternal infections with coxsackievirus during pregnancy are relatively common, fetal infections are quite rare. Coxsackievirus infection in utero has been associated with myocarditis, but has not been proven a teratogen.Case: A patient whose fetus had structural cardiac anomalies and hydrops was found to have an intrauterine infection with Coxsackie B-1 virus, proven by virus isolation from the amniotic fluid. This infection led to increasing intrauterine hydrops and subsequent neonatal death. Conclusion: This interesting association of intrauterine infection with Coxsackie B virus and structural cardiac anomalies in the fetus warrants further investigation.


Sign in / Sign up

Export Citation Format

Share Document