scholarly journals Der Wärmehaushalt periglazialer Hochgebirgsböden – Zusammenhänge zwischen Bodentiefe und Frostwechseln (Nördlicher Tian Shan, Kasachstan)

2009 ◽  
Vol 58 (1) ◽  
pp. 70-85
Author(s):  
Henry Munack ◽  
Hilmar Schröder

Abstract. Ground temperature measurements have been carried out at eleven different sites of the Prokhodnaja valley in the high mountains of the Zailijskij Alatau (Northern Tian Shan, Kazakhstan) between the summers of 2003 and 2004. For this purpose the periglacial zone and adjacent altitudinal zones have been examined between 2,500 and 4,000 m asl with an equidistance of 250 m. The influences of the altitude, the exposure as well as the depth below the earth’s surface on the thermal content and condition of periglacial soils have been considered. The measurements provide useful information about the relations between quantity and quality of freeze-thaw action and the parameters mentioned above.

2018 ◽  
Vol 30 (1) ◽  
pp. 3-18 ◽  
Author(s):  
Balázs Nagy ◽  
Ádám Ignéczi ◽  
József Kovács ◽  
Zoltán Szalai ◽  
László Mari

1977 ◽  
Vol 34 (12) ◽  
pp. 2369-2373 ◽  
Author(s):  
Doris Fraser Hiltz ◽  
D. H. North ◽  
Barbara Smith Lall ◽  
R. A. Keith

Refrozen silver hake (Merluccius bilinearis), processed as fillets and minced flesh after thawing of stored round fish that had been frozen within 14 h of capture, underwent rapid deterioration during storage at −18 °C compared with once-frozen control materials from the same lot of fish. The estimated maximum storage life of silver hake refrozen as fillets after 3 and 6 mo storage of the round fish at −25 °C was reduced to about 4.5 and 1 mo, respectively, from 10 mo for once-frozen control fillets. Quality of the refrozen materials immediately after thawing and refreezing was similar to that of the round-frozen fish, except after 6 mo, where some initial deterioration occurred, particularly in minced flesh. Minced flesh was more unstable in frozen storage than fillets. In all once- and twice-frozen materials, formation of dimethylamine occurred concomitantly with decrease in protein extractability. Round-frozen fish underwent no loss in protein extractability during 6 mo storage at −25 °C, but some lipid hydrolysis occurred. These results suggest that the freeze–thaw–refreeze process as applied to silver hake will yield a final product of acceptable quality provided that storage of the round fish does not exceed 3–4 mo and that the refrozen materials are marketed within a month after processing. Key words: silver hake, Merluccius bilinearis, refrozen storage, dimethylamine, minced flesh


Finisterra ◽  
2012 ◽  
Vol 44 (87) ◽  
Author(s):  
Javier Santos-González ◽  
Rosa González-Gutiérrez ◽  
Amélia Gómes-Villar ◽  
José Redondo-Vega

Ground temperature data obtained from 2002 to 2007 in sites near relict rock glaciers in the cantabrian mountains, at altitudes between 1500 and 2300 meters is analysed. Snow cover lasted between 3 and 9 months and had a strong influence on the thermal regime. When snow was present, the soil was normally frozen in the first 5 to 10 cm, but daily freeze-thaw cycles were rare. In well developed soils located at sunny faces frost penetration rarely reached more than 10 cm. on the contrary in shady and windy faces with scarce snow cover, frost penetration reached, at least, 40 cm. In persistent snow patches the temperature was stable at 0 ºc, even in relict rock glaciers, where subnival winter air fluxes appear to have been very rare.


2005 ◽  
Vol 16 (4) ◽  
pp. 354-378 ◽  
Author(s):  
S. JITTINANDANA ◽  
P.B. KENNEY ◽  
S.D. SLIDER
Keyword(s):  

2021 ◽  
Author(s):  
Andreas Kellerer-Pirklbauer ◽  
Gerhard Karl Lieb

<p>Ground temperatures in alpine environments are severely influenced by slope orientation (aspect), slope inclination, local topoclimatic conditions, and thermal properties of the rock material. Small differences in one of these factors may substantially impact the ground thermal regime, weathering by freeze-thaw action or the occurrence of permafrost. To improve the understanding of differences, variations, and ranges of ground temperatures at single mountain summits, we studied the ground thermal conditions at a triangle-shaped (plan view), moderately steep pyramidal peak over a two-year period (2018-2020).</p><p>We installed 18 monitoring sites with 23 sensors near the summit of Innerer Knorrkogel (2882m asl), in summer 2018 with one- and multi-channel datalogger (Geoprecision). All three mountain ridges (east-, northwest-, and southwest-facing) and flanks (northeast-, west-, and south-facing) were instrumented with one-channel dataloggers at two different elevations (2840 and 2860m asl) at each ridge/flank to monitor ground surface temperatures. Three bedrock temperature monitoring sites with shallow boreholes (40cm) equipped with three sensors per site at each of the three mountain flanks (2870m asl) were established. Additionally, two ground surface temperature monitoring sites were installed at the summit.</p><p>Results show remarkable differences in mean annual ground temperatures (MAGT) between the 23 different sensors and the two years despite the small spatial extent (0.023 km²) and elevation differences (46m). Intersite variability at the entire mountain pyramid was 3.74°C in 2018/19 (mean MAGT: -0.40°C; minimum: -1.78°C; maximum: 1.96°C;) and 3.27°C in 2019/20 (mean MAGT: 0.08°C; minimum: -1.54°C; maximum: 1,73°C;). Minimum was in both years at the northeast-facing flank, maximum at the south-facing flank. In all but three sites, the second monitoring year was warmer than the first one (mean +0.48°C) related to atmospheric differences and site-specific snow conditions. The comparison of the MAGT-values of the two years (MAGT-2018/19 minus MAGT-2019/20) revealed large thermal inhomogeneities in the mountain summit ranging from +0.65° (2018/19 warmer than 2019/20) to -1.76°C (2018/19 colder than 2019/20) at identical sensors. Temperature ranges at the three different aspects but at equal elevations were 1.7-2.2°C at ridges and 1.8-3.7°C at flanks for single years. The higher temperature range for flank-sites is related to seasonal snow cover effects combined with higher radiation at sun-exposed sites. Although the ground temperature was substantially higher in the second year, the snow cover difference between the two years was variable. Some sites experienced longer snow cover periods in the second year 2019/20 (up to +85 days) whereas at other sites the opposite was observed (up to -85 days). Other frost weathering-related indicators (diurnal freeze-thaw cycles, frost-cracking window) show also large intersite and interannual differences.</p><p>Our study shows that the thermal regime at a triangle-shaped moderately steep pyramidal peak is very heterogeneous between different aspects and landforms (ridge/flank/summit) and between two monitoring years confirming earlier monitoring and modelling results. Due to high intersite and interannual variabilities, temperature-related processes such as frost-weathering can vary largely between neighbouring sites. Our study highlights the need for systematic and long-term ground temperature monitoring in alpine terrain to improve the understanding of small- to medium-scale temperature variabilities.</p>


2020 ◽  
Vol 43 (11) ◽  
Author(s):  
Hongyao Jiang ◽  
Min Zhang ◽  
Yanan Sun ◽  
Bhesh Bhandari ◽  
Xi Wang

2020 ◽  
Vol 65 ◽  
pp. 102454 ◽  
Author(s):  
Jiaheng Li ◽  
Jiyong Shi ◽  
Xiaowei Huang ◽  
Xiaobo Zou ◽  
Zhihua Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document