scholarly journals The Cerebrospinal Fluid Aβ1–42/Aβ1–40 Ratio Improves Concordance with Amyloid-PET for Diagnosing Alzheimer’s Disease in a Clinical Setting

2017 ◽  
Vol 60 (2) ◽  
pp. 561-576 ◽  
Author(s):  
Ellis Niemantsverdriet ◽  
Julie Ottoy ◽  
Charisse Somers ◽  
Ellen De Roeck ◽  
Hanne Struyfs ◽  
...  
2021 ◽  
pp. 1-12
Author(s):  
Luca Sacchi ◽  
Tiziana Carandini ◽  
Giorgio Giulio Fumagalli ◽  
Anna Margherita Pietroboni ◽  
Valeria Elisa Contarino ◽  
...  

Background: Association between cerebrospinal fluid (CSF)-amyloid-β (Aβ)42 and amyloid-PET measures is inconstant across the Alzheimer’s disease (AD) spectrum. However, they are considered interchangeable, along with Aβ 42/40 ratio, for defining ‘Alzheimer’s Disease pathologic change’ (A+). Objective: Herein, we further characterized the association between amyloid-PET and CSF biomarkers and tested their agreement in a cohort of AD spectrum patients. Methods: We include ed 23 patients who underwent amyloid-PET, MRI, and CSF analysis showing reduced levels of Aβ 42 within a 365-days interval. Thresholds used for dichotomization were: Aβ 42 <  640 pg/mL (Aβ 42+); pTau >  61 pg/mL (pTau+); and Aβ 42/40 <  0.069 (ADratio+). Amyloid-PET scans were visually assessed and processed by four pipelines (SPMCL, SPMAAL, FSGM, FSWC). Results: Different pipelines gave highly inter-correlated standardized uptake value ratios (SUVRs) (rho = 0.93–0.99). The most significant findings were: pTau positive correlation with SPMCL SUVR (rho = 0.56, p = 0.0063) and Aβ 42/40 negative correlation with SPMCL and SPMAAL SUVRs (rho = –0.56, p = 0.0058; rho = –0.52, p = 0.0117 respectively). No correlations between CSF-Aβ 42 and global SUVRs were observed. In subregion analysis, both pTau and Aβ 42/40 values significantly correlated with cingulate SUVRs from any pipeline (R2 = 0.55–0.59, p <  0.0083), with the strongest associations observed for the posterior/isthmus cingulate areas. However, only associations observed for Aβ 42/40 ratio were still significant in linear regression models. Moreover, combining pTau with Aβ 42 or using Aβ 42/40, instead of Aβ 42 alone, increased concordance with amyloid-PET status from 74% to 91% based on visual reads and from 78% to 96% based on Centiloids. Conclusion: We confirmed that, in the AD spectrum, amyloid-PET measures show a stronger association and a better agreement with CSF-Aβ 42/40 and secondarily pTau rather than Aβ 42 levels.


2016 ◽  
Vol 12 ◽  
pp. P1154-P1154
Author(s):  
Ellis Niemantsverdriet ◽  
Tobi Van den Bossche ◽  
Sara Van Mossevelde ◽  
Julie Ottoy ◽  
Jeroen Verhaeghe ◽  
...  

2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Maria João Leitão ◽  
Anuschka Silva-Spínola ◽  
Isabel Santana ◽  
Veronica Olmedo ◽  
Alicia Nadal ◽  
...  

Abstract Background Ongoing efforts within the Alzheimer’s disease (AD) field have focused on improving the intra- and inter-laboratory variability for cerebrospinal fluid (CSF) biomarkers. Fully automated assays offer the possibility to eliminate sample manipulation steps and are expected to contribute to this improvement. Recently, fully automated chemiluminescence enzyme immunoassays for the quantification of all four AD biomarkers in CSF became available. The aims of this study were to (i) evaluate the analytical performance of the Lumipulse G β-Amyloid 1-42 (restandardized to Certified Reference Materials), β-Amyloid 1-40, total Tau, and pTau 181 assays on the fully automated LUMIPULSE G600II; (ii) compare CSF biomarker results of the Lumipulse G assays with the established manual ELISA assays (INNOTEST®) from the same company (Fujirebio); and (iii) establish cut-off values and the clinical performance of the Lumipulse G assays for AD diagnosis. Methods Intra- and inter-assay variation was assessed in CSF samples with low, medium, and high concentrations of each parameter. Method comparison and clinical evaluation were performed on 40 neurological controls (NC) and 80 patients with a diagnosis of probable AD supported by a follow-up ≥ 3 years and/or positive amyloid PET imaging. A small validation cohort of 10 NC and 20 AD patients was also included to validate the cut-off values obtained on the training cohort. Results The maximal observed intra-assay and inter-assay coefficients of variation (CVs) were 3.25% and 5.50%, respectively. Method comparisons revealed correlation coefficients ranging from 0.89 (for Aβ40) to 0.98 (for t-Tau), with those for Aβ42 (0.93) and p-Tau (0.94) in-between. ROC curve analysis showed area under the curve values consistently above 0.85 for individual biomarkers other than Aβ40, and with the Aβ42/40, Aβ42/t-Tau, and Aβ42/p-Tau ratios outperforming Aβ42. Validation of the cut-off values in the independent cohort showed a sensitivity ranging from 75 to 95% and a specificity of 100%. The overall percentage of agreement between Lumipulse and INNOTEST was very high (> 87.5%). Conclusions The Lumipulse G assays show a very good analytical performance that makes them well-suited for CSF clinical routine measurements. The good clinical concordance between the Lumipulse G and INNOTEST assays facilitates the implementation of the new method in routine practice.


2020 ◽  
Author(s):  
Jongmin Lee ◽  
Hyemin Jang ◽  
Sung Hoon Kang ◽  
Jaeho Kim ◽  
Ji-Sun Kim ◽  
...  

Abstract Background Cerebrospinal fluid (CSF) biomarkers are increasingly used in clinical practice for the diagnosis of Alzheimer’s disease (AD). We aimed to 1) determine cutoff values of CSF biomarkers for AD, 2) investigate their clinical utility by estimating a concordance with amyloid positron emission tomography (PET), and 3) apply AT (amyloid/tau) classification based on CSF results. Methods We performed CSF analysis in 51 normal controls (NC), 23 amnestic mild cognitive impairment (aMCI) and 65 AD dementia (ADD) patients at the Samsung Medical Center in Korea. We tried to develop cutoff of CSF biomarkers for differentiating ADD from NC using receiver operating characteristic analysis. We also investigated a concordance between CSF and amyloid PET results and applied AT classification scheme based on CSF biomarker abnormalities to characterize our participants. Results CSF Aβ42, total tau (t-tau) and phosphorylated tau (p-tau) significantly differ across the three groups. The area under curve for the differentiation between NC and ADD was highest in t-tau/Aβ42(0.994) followed by p-tau/Aβ42(0.963), Aβ42(0.960) and t-tau (0.918). The concordance rate between CSF Aβ42 and amyloid PET results was 92%. Finally, AT classification based on CSF biomarker abnormalities led to a majority of NC categorized into A-T-(72%), aMCI as A + T-(52%)/A + T+(30%), and AD as A + T+(56%)/A + T-(41%). Conclusion CSF biomarkers had high sensitivity and specificity in differentiating ADD from NC and were as accurate as amyloid PET. The AT group distribution was comparable to those of previous studies, which may serve to predict the prognosis more accurately than amyloid PET alone in the future.


2020 ◽  
Vol 4 (1) ◽  
pp. 15-19 ◽  
Author(s):  
Nicolai Maximilian Stoye ◽  
Patrick Jung ◽  
Malena dos Santos Guilherme ◽  
Johannes Lotz ◽  
Andreas Fellgiebel ◽  
...  

2016 ◽  
Vol 55 (2) ◽  
pp. 813-822 ◽  
Author(s):  
Piotr Lewczuk ◽  
Anja Matzen ◽  
Kaj Blennow ◽  
Lucilla Parnetti ◽  
Jose Luis Molinuevo ◽  
...  

2021 ◽  
pp. 1-6
Author(s):  
Dominique Gouilly ◽  
Camille Tisserand ◽  
Leonor Nogueira ◽  
Laura Saint-Lary ◽  
Vanessa Rousseau ◽  
...  

The consistency of cerebrospinal fluid amyloid-β (Aβ)42/40 ratio and Aβ 42 has not been assessed in the AT(N) classification system. We analyzed the classification changes of the dichotomized amyloid status (A+/A–) in 363 patients tested for Alzheimer’s disease biomarkers after Aβ 42 was superseded by the Aβ 42/40 ratio. The consistency of Aβ 42 and the Aβ 42/40 ratio was very low. Notably, the proportions of “false” A+T–patients were considerable (74–91%) and corresponded mostly to patients not clinically diagnosed with Alzheimer’s disease. Our results suggest that the interchangeability of Aβ 42/40 ratio and Aβ 42 is limited for classifying patients in clinical setting using the AT(N) scheme.


2019 ◽  
Vol 68 (3) ◽  
pp. 1061-1069 ◽  
Author(s):  
Chloé Manca ◽  
Lucie Hopes ◽  
Anna Kearney-Schwartz ◽  
Véronique Roch ◽  
Gilles Karcher ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document