scholarly journals Kualitas Sumber Air Minum Masyarakat Kampung Yokiwa Distrik Sentani Timur Secara Bakteriologis

2018 ◽  
Vol 1 (2) ◽  
pp. 65-71
Author(s):  
Ima F. Patasik ◽  
Daniel Lantang

The aim of this study was to observe the presence of coliform bacteria and the level of contamination in outlet water of Sentani lake, especially in Jaifuri river. The study was done from Januari-April 2009 in 3 sampling areas: outlet of the lake (A), in between outlet and the river (B), and in Jaifuri river (C). Samples then be analized in Biology Laboratory, FMIPA University of Cenderawasih using MPN (Most Probable Number) series 3-3-3. Furthermore, the result then compared with the quality standard of dringking water (Peraturan Menteri Kesehatan RI No 416/MENKES/PER/IX1990). The result showed that coliform of sample A was 9.300 MPN/ 100 ml, sample B was 4.300 MPN/100 ml and sample C was 24.000 MPN/ 100 ml. That condition was above the maximum level of contamination of dringking water (0/100 ml). In addition, the biochemical test showed that Escherichia coli and Klebsiella pneumoniae were found in that water samples.  Key words: Coliform, Escherichia coli, outlet of Sentani lake, Jaifuri river, East Sentani. 

Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2021 ◽  
Vol 10 (1) ◽  
pp. 23
Author(s):  
Muhammad Rayhan Braja Gitawama ◽  
Netti Suharti ◽  
Nora Harminarti

The National Food and Drug Agency has controlled the refill drinking water in drinking water depots and also controlled food at school canteens ranging from elementary, junior high, to high school, but the National Food and Drug Agency never do food quality controlling in canteens at universities. Objectives: To identified the contamination by coliform and E. coli bacteria in drinking water at Andalas University canteen. Methods: This research was descriptive to identify coliform bacteria on  15 drinking water at the Andalas University faculty canteens.  Samples were taken directly using a sterile bottle, while data analysis using Most Probable Number  (MPN)  tables 5-1-1 and the presence of E. coli bacteria colonies from drinking water samples. Results: 9 of 15 water samples were contaminated by coliform bacteria with the highest MPN index of 240/100 ml that was found in 2 samples. From 9 samples containing coliform bacteria, all of them were found to contain E. coli bacteria. Conclusion: Most of the samples were contaminated by coliform and E. coli bacteria. Drinking water served using a kettle was more contaminated than drinking water served using gallons.Keywords: Coliform, Escherichia coli, MPN


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2019 ◽  
Vol 2 (2) ◽  
pp. a13-19
Author(s):  
ELEXSON NILLIAN ◽  
AMIZA NUR ◽  
DIYANA NUR ◽  
AMIRAH ZAKIRAH ◽  
GRACE BEBEY

Contamination of drinks with E. coli O157:H7 served in food premises such as restaurants can cause haemorrhagic colitis and haemolytic uremic syndrome to humans. The presence or absence of faecal pathogen was demonstrated using coliform group as indicator microorganisms. Therefore, this study was conducted to detect the presence of E. coli O157:H7 in drinking water from food restaurant premise in Kota Samarahan and Kuching to ensure safe and potable drinking water is served to the consumer. A total of thirty (n=30) drink samples including six types of each of the samples are cold plain water, iced tea, iced milo, syrup and iced milk tea. Most Probable Number (MPN) procedure was used in this study to enumerate the MPN values of coliform bacteria in each drink collected. A total of 53.33% (16/30) of the drink samples showed positive E. coli detection. Then, the PCR assay showed 6.25% (one out of 16 isolates) samples were positive and carried stx1 gene produced by E. coli O157:H7 in iced milo sample types. This study showed the drinks collected from food premises was contaminated with faecal contamination, which was not safe to drink by the consumer. Therefore, preventive actions should be taken to prevent foodborne illness outbreak in future


2020 ◽  
Vol 36 (2) ◽  
pp. 75-77
Author(s):  
Anindita Bhowmik ◽  
Sunjukta Ahsan

Majority of the population of Bangladesh depend on tap or surface water as their source of water supply. This study was carried out to examine the microbial quality of both water and soil collected from different places using the multiple tube fermentation technique to determine coliform count by the most probable number (MPN) method in brilliant green lactose broth (BGLB) media.Inoculum from positive tubes of the presumptive test were further transferred on eosinemethylene blue (EMB) and MacConkey agar.The organisms isolated were further characterized using biochemical tests. Out of 93 water samples, 30 (32.26%) indicated the presence of lactose fermenter and gas producer in all 3 tubes of dilution series using inoculum quantities of 1.0, 0.1 and 0.01 ml, whereas out of 85 soil samples, 45 (52.94%) showed acid and gas production in all 3 tubes of dilution series.Among 85 soil samples, 40 samples that contained at least one positive in each dilution series and among 93 water samples, 31 samples that contained at least one positive in each dilution series were further re-identified with biochemical tests.This study showed 30.59% soil isolates and 26.88% water isolates were Escherichia coli which highlighted the fact that both water and soil act as a major reservoir of E.coli, which indicates possible fecal contamination as well as presence of potentially pathogenic E. coli. Bangladesh J Microbiol, Volume 36 Number 2 December 2019, pp 75-77


2006 ◽  
Vol 89 (1) ◽  
pp. 100-114 ◽  
Author(s):  
Hidemasa Kodaka ◽  
Shingo Mizuochi ◽  
Hajime Teramura ◽  
Tadanobu Nirazuka ◽  
David Goins ◽  
...  

Abstract Compact Dry E. coli/Coliform Count (EC) is a ready-to-use test method for the enumeration of Escherichia coli and coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated onto the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35C for 2024 h and the colonies counted without any further working steps. The Compact Dry EC medium plates were validated as an analysis tool for determining colony-forming units (CFU) of E. coli and coliform bacteria from a variety of raw meats using 5 different types of raw meats. The performance tests were conducted at 35C. In all studies performed, no apparent differences were observed between the Compact Dry ECmethod and theAOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.93 (E. coli) and r2 = 0.93 (coliform bacteria) could be assigned, as stated in the application for Performance-Tested MethodSM.


Author(s):  
Sidratun Nur Chowdhury ◽  
Nazifa Rafa ◽  
Sayed Mohammad Nazim Uddin ◽  
A. K. M. Moniruzzaman Mollah

Abstract Globally, unsafe water supplies due to contamination with fecal coliforms are major issues in urban slums. To determine the presence of microbial risk, water samples were collected from three slums in the port city Chattogram and the most probable number (MPN) method was used to test for the presence of fecal coliform. All of the samples tested positive by the MPN test. The highest count was 1,100 MPN/100 mL and the lowest count was 7.2 MPN/100 mL. Water stored in containers was prone to being more contaminated than water collected directly from the source. To understand the antibiotic resistivity of the coliform bacteria isolated from the water samples, antibiotic susceptibility was evaluated using the Kirby-Bauer disc method for six antibiotics. All the bacteria were 100% resistant to penicillin-G and ampicillin, and 91.7% showed resistance to amoxicillin and mecillinam. An integrated approach to water, sanitation, and hygiene education must be undertaken when providing sustainable interventions in slums.


1998 ◽  
Vol 61 (4) ◽  
pp. 444-449 ◽  
Author(s):  
D. E. TOWNSEND ◽  
R. L. IRVING ◽  
A. NAQUI

SimPlate for coliforms and Escherichia coli (CEc) is a new method for the detection and quantification of coliforms and E. coli in food. Internal validation of the method was carried out at IDEXX Laboratories (Westbrook, ME) with 180 food samples representing a variety of different food matrices and compared against three-tube MPN (most probable number), VRBA (violet red bile agar) + MUG, and Petrifilm (E. coli count) methods. SimPlate CEc was highly correlated with each of these methods for the quantification of coliform bacteria (r ≥ 0.90). An insignificant number of food samples were found to contain E. coli; therefore, no meaningful correlation data could be generated. Four hundred forty-four additional food samples were tested at five collaborating laboratories for the presence of coliforms and E. coli using SimPlate CEc and either VRBA + MUG or Petrifilm (E. coli count). Regression analysis of data from SimPlate for CEc versus Petrifilm E. coli count plates generated correlation coefficients (r) of at least 0.89 for total coliforms and at least 0.90 for generic E. coli. Correlation coefficients between SimPlate for CEc and VRBA + MUG data were at least 0.90 for coliforms and at least 0.86 for E. coli. SimPlate for CEc demonstrated better recovery of E. coli than Petrifilm when high populations of bacteria were present. E. coli was not detected in 20 of 50 (40%) raw milk samples tested by the Petrifilm method due to the presence of interfering coliform and noncoliform bacteria. It is concluded that SimPlate for CEc is a suitable alternative for determining numbers of coliform bacteria and E. coli in food.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Ruth Adi Agyo ◽  
Raph Agbo Ofukwu ◽  
Anthony Ekle J. Okoh ◽  
Charity A. Agada

Aim: This study aimed at examined the presence of coliform bacteria in private wells and boreholes (BH) in peri-urban areas of Makurdi, Benue State, Nigeria, using the approaches of most probable number (MPN) index and coliform count. Materials and Methods: Seven hundred and sixty-eight water samples were randomly collected during a 1-year period from non-cased wells, burn brick cased wells (BBW), concrete cased wells, and BH in four locations; A, B, C, and D during the wet and dry seasons. One liter of water was obtained from each well at every visit to the four sites, and eight water samples were collected from each visit. The samples were analyzed using multiple tube fermentation methods and pour plate techniques to determine the MPN of coliform/100 ml of water, reading from the MPN statistics table. Results: One-way analysis of variance statistics was applied using Duncan's new multiple range test to separate the means where there was a significant difference. The result revealed that the MPN index and total coliform counts in all the wells in the locations were above the World Health Organization (WHO) permissible limit for potable water. The highest MPN index of 54.807 was recorded in Location A and followed by 42.679 in Location B. The MPN index in Locations C and D was 36.740 and 30.943, respectively. There was significantly (p=0.000) higher total coliform count in the wet season (41.48±7.09) than in the dry season (38.33±2.83). Conclusion: This study shows the presence of coliform bacteria isolates in all the wells and BH that exceeded the WHO permissible limits for drinking water. The water from these sources is unsafe for drinking except after dosing with appropriate germicides. Sensitization of the population on the actions they can take to make the water safe for domestic use is suggested.


Author(s):  
Angriani Fusvita ◽  
Susanti Susanti ◽  
Bobi Anggriawan

Penelitian ini bertujuan untuk mengetahui kualitas Air di Desa Rarowatu Kabupaten Bombana. Pemeriksaan coliform pada air sumur bor dan air swadaya masyarakat menggunakan Metode Most Probable Number (MPN). Pada perlakuan ini terdiri dari presumptive test yang menggunakan media Lactose Broth (LB) dengan metode 3 seri tabung, Tahap berikutnya confirmative test dengan menggunakan media Brillian Green Lactose Broth (BGLB). Pada identifikasi  Escherichia coli  menggunakan media Eosin Methylene Blue Agar, pewarnaan Gram dan media uji biokimia. Hasil penelitian menunjukkan sampel yang terdiri dari 7 sampel air sumur bor dan I sampel air swadaya masyarakat berdasarkan uji MPN mencapai 2400/100 ml. Hasil identifikasi menggunakan media EMBA menunjukkan koloni yang berwarna hijau metalik pada sampel air swadaya  serta  dilakukan pewarnaan Gram menunjukkan bentuk basil pendek dan gram negative. Hasil uji biokimia menunjukkan hasil uji indol positif, methyl red positif, voges proskauer negatif dan uji sitrat negatif. Uji IMViC dapat disimpulkan bahwa bakteri pada kode sampel D memiliki sifat yang sama terhadap bakteri E. coli. Kata kunci :  Coliform, Identifikasi, Escherichia coli, BombanaABSTRACTThis study aims to determine the quality of water in Rarowatu Village, Bombana Regency. Coliform examination in borehole water and community self-water using the Most Probable Number (MPN) Method. This treatment consists of a presumptive test that uses Lactose Broth (LB) media with the tube 3 series method. The next stage is the confirmative test using Brilliant Green Lactose Broth (BGLB) media. The identification of Escherichia coli using Eosin Methylene Blue Agar media, Gram staining, and biochemical test media. The results of the study showed that samples consisting of 7 samples of bore well water and I community self-water samples based on the MPN test reached 2400/100 ml. The identification results using EMBA media showed that metallic green colonies in self-help water samples and Gram staining performed showed short and gram-negative bacilli forms. The results of biochemical tests showed that swadaya water samples were Escherichia coli species.Keywords: Coliform, Identification, Escherichia coli, Bombana


Sign in / Sign up

Export Citation Format

Share Document