Anchorage Capacity and Performance in Plain and Steel-Fibre-Reinforced Concrete

Author(s):  
R. Nilforoush ◽  
G. Pia ◽  
M. Nilsson ◽  
L. Elfgren

<p>Nowadays, prefabricated concrete components made from Steel-Fiber-Reinforced Concrete (SFRC) are widely used in the construction industry. These components are often connected to existing or new structural elements through various fastening systems. Previous studies have shown that the addition of steel fibers to concrete mixture substantially improves the fracture properties of concrete. To date, however, rather limited research is available on the behavior of fastening systems in SFRC. To improve the current knowledge of fastening systems to SFRC structures, a pilot experimental study is carried out on cast-in-place anchor bolts embedded in Plain Concrete (PC) and SFRC members. In this study, the influence of the presence of steel fibers and concrete compressive strength on the anchorage capacity and performance is evaluated. Furthermore, the applicability of current design methods is evaluated for anchorage systems in SFRC.</p>

2009 ◽  
Vol 79-82 ◽  
pp. 1771-1774
Author(s):  
Min Bai ◽  
Di Tao Niu ◽  
Xiong Wu

In recent years, the concrete material subject to chloride corrosion which impacts greatly on the durability of the building project in the marine or coastal environment has been reported repeatedly. With the problems becoming more and more serious, much attention has been paid on it gradually. To improve the durability of the concrete structure in the marine environment, the author tried to add the different content of steel fiber into the concrete and research the permeability of the concrete in the chloride environment. Four different volumes of steel fiber were selected to prepare the concrete. The dates of the proportion are as follows, 1)0.5%; 2)1%; 3)1.5%; 4)2%. Leave the steel fiber reinforced concrete and plain concrete to soak in the sodium chloride solution which mass percent is 3.5%. The soak time is 30, 60, 90,120, 180 days separately. Among this, the test items include the penetration depth of chloride, the chloride ion content and the splitting strength after soaking period. As a result of the test, it is demonstrated that chloride penetration-resistant of steel fiber reinforced concrete is better than plain concrete. The best performance is obtained when the content of steel fiber is 1.5%. The results will be very useful to the concrete professional dealing with chloride-ion penetration. In conclusion, it is convinced that the application of this result in marine engineering will bring well economic and social environmental benefits for the society.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 445
Author(s):  
José Valdez Aguilar ◽  
César A. Juárez-Alvarado ◽  
José M. Mendoza-Rangel ◽  
Bernardo T. Terán-Torres

Concrete barely possesses tensile strength, and it is susceptible to cracking, which leads to a reduction of its service life. Consequently, it is significant to find a complementary material that helps alleviate these drawbacks. The aim of this research was to determine analytically and experimentally the effect of the addition of the steel fibers on the performance of the post-cracking stage on fiber-reinforced concrete, by studying four notch-to-depth ratios of 0, 0.08, 0.16, and 0.33. This was evaluated through 72 bending tests, using plain concrete (control) and fiber-reinforced concrete with volume fibers of 0.25% and 0.50%. Results showed that the specimens with a notch-to-depth ratio up to 0.33 are capable of attaining a hardening behavior. The study concludes that the increase in the dosage leads to an improvement in the residual performance, even though an increase in the notch-to-depth ratio has also occurred.


2021 ◽  
pp. 136943322098165
Author(s):  
Hossein Saberi ◽  
Farzad Hatami ◽  
Alireza Rahai

In this study, the co-effects of steel fibers and FRP confinement on the concrete behavior under the axial compression load are investigated. Thus, the experimental tests were conducted on 18 steel fiber-reinforced concrete (SFRC) specimens confined by FRP. Moreover, 24 existing experimental test results of FRP-confined specimens tested under axial compression are gathered to compile a reliable database for developing a mathematical model. In the conducted experimental tests, the concrete strength was varied as 26 MPa and 32.5 MPa and the steel fiber content was varied as 0.0%, 1.5%, and 3%. The specimens were confined with one and two layers of glass fiber reinforced polymer (GFRP) sheet. The experimental test results show that simultaneously using the steel fibers and FRP confinement in concrete not only significantly increases the peak strength and ultimate strain of concrete but also solves the issue of sudden failure in the FRP-confined concrete. The simulations confirm that the results of the proposed model are in good agreement with those of experimental tests.


2012 ◽  
Vol 174-177 ◽  
pp. 668-671
Author(s):  
He Ting Zhou

Steel fiber has a fine nature in reinforcing concrete. This essay aims to find out the influence of physical forms of steel fiber on its nature of reinforcement. By comparing two types of cement mortar reinforced by steel fibers, it is found that spiral steel fibers have a better bond strength with matrix than straight ones. Therefore, a conclusion could be drawn that physical forms of the steel fiber play a significant role in steel fiber reinforced concrete, and the experiment also serves a rewarding reference to the application of spiral steel fibers.


Author(s):  
Natalia Sharma

Abstract: Reinforced concrete structures are frequently in need of repair and strengthening as a result of numerous environmental causes, ageing, or material damage under intense stress conditions, as well as mistakes made during the construction process. RC structures are repaired using a variety of approaches nowadays. The usage of FRC is one of the retrofitting strategies. Steel fiber reinforced concrete (SFRC) was used in this investigation because it contains randomly dispersed short discrete steel fibers that operate as internal reinforcement to improve the cementitious composite's characteristics (concrete). The main rationale for integrating small discrete fibers into a cement matrix is to reduce the amount of cement used. The principal reason for incorporating short discrete fibers into a cement matrix is to reduce cracking in the elastic range, increase the tensile strength and deformation capacity and increase the toughness of the resultant composite. These properties of SFRC primarily depend upon length and volume of Steel fibers used in the concrete mixture. In India, the steel fiber reinforced concrete (SFRC) has seen limited applications in several structures due to the lack of awareness, design guidelines and construction specifications. Therefore, there is a need to develop information on the role of steel fibers in the concrete mixture. The experimental work reported in this study includes the mechanical properties of concrete at different volume fractions of steel fibers. These mechanical properties include compressive strength, split tensile strength and flexural strength and to study the effect of volume fraction and aspect ratio of steel fibers on these mechanical properties. However, main aim of the study was significance of reinforced concrete beams strengthened with fiber reinforced concrete layer and to investigate how these beams deflect under strain. The objective of the investigation was finding that applying FRC to strengthen beams enhanced structural performance in terms of ultimate load carrying capacity, fracture pattern deflection, and mode of failure or not.


2019 ◽  
Vol 10 (1) ◽  
pp. 241
Author(s):  
Wenjin Yao ◽  
Weiwei Sun ◽  
Ze Shi ◽  
Bingcheng Chen ◽  
Le Chen ◽  
...  

This paper experimentally investigates the blast-resistant characteristics of hybrid fiber-reinforced concrete (HFRC) panels by contact detonation tests. The control specimen of plain concrete, polypropylene (PP), polyvinyl alcohol (PVA) and steel fiber-reinforced concrete were prepared and tested for characterization in contrast with PP-Steel HFRC and PVA-Steel HFRC. The sequent contact detonation tests were conducted with panel damage recorded and measured. Damaged HFRC panels were further comparatively analyzed whereby the blast-resistance performance was quantitively assessed via damage coefficient and blast-resistant coefficient. For both PP-Steel and PVA-Steel HFRC, the best blast-resistant performance was achieved at around 1.5% steel + 0.5% PP-fiber hybrid. Finally, the fiber-hybrid effect index was introduced to evaluate the hybrid effect on the explosion-resistance performance of HFRC panels. It revealed that neither PP-fiber or PVA-fiber provide positive hybrid effect on blast-resistant improvement of HFRC panels.


Fibers ◽  
2018 ◽  
Vol 6 (4) ◽  
pp. 93 ◽  
Author(s):  
Boglárka Bokor ◽  
Máté Tóth ◽  
Akanshu Sharma

Increased loading rates on fasteners may be caused by high ground accelerations as a consequence of e.g., nuclear explosions, earthquakes or car collisions. It was concluded by Hoehler et al. (2006) that fasteners under rapid loading rates show an increased ultimate resistance in the concrete dominant failure modes or the ultimate resistance is at least as large as under quasi-static loading. Due to the increased demand on using fasteners in steel fiber reinforced concrete (SFRC), it is intended to show how the ultimate concrete cone capacity of fasteners changes under higher than quasi-static loading rate in normal plain concrete (PC) and in SFRC. This paper presents the results of an extensive experimental program carried out on single fasteners loaded in tension in normal plain concrete and in SFRC. The test series were conducted using a servo-hydraulic loading cylinder. The tests were performed in displacement control with a programmed ramp speed of 1, 100, 1000, and 3500 mm/min. This corresponded to calculated initial loading rates ranging between 0.4 and 1600 kN/s. The results of the tension tests clearly show that the rate-dependent behavior of fasteners in SFRC with 30 and 50 kg/m3 hooked-end-type fibers fits well to the previously reported rate-dependent concrete cone behavior in normal plain concrete. Additionally, a positive influence of the fibers on the concrete cone capacity is clearly visible.


2010 ◽  
Vol 168-170 ◽  
pp. 1762-1766
Author(s):  
Min Sun ◽  
Di Jiang Wen ◽  
Peng Xie

The interface bond between steel fibers and concrete matrix is the key of carrying capacity of steel fiber reinforced concrete(SFRC). In marine tidal fluctuation zone and splashed area, steel fibers will be rusty, and the bending toughness of SFRC was weakened. In this study, we tried to improve corrosion resistance of steel fiber and the interface bond strength by depositing zinc phosphate coating on steel fiber. These zinc phosphate steel fiber reinforced concrete(ZSFRC) have higher anti-corrosion ability. After corrosion they still have higher bending toughness than common SFRC.


2012 ◽  
Vol 5 (1) ◽  
pp. 1-11 ◽  
Author(s):  
A. D. de Figueiredo ◽  
A. de la Fuente ◽  
A. Aguado ◽  
C. Molins ◽  
P. J. Chama Neto

This paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part ("Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test"), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.