MHD/gas turbine/steam turbine triple combined cycle with thermochemical heat recovery

1997 ◽  
Author(s):  
Yoshiaki Aoki ◽  
Kazutomo Ohtake ◽  
Naoyuki Kayukawa ◽  
Yoshiaki Aoki ◽  
Kazutomo Ohtake ◽  
...  
2020 ◽  
Vol 8 (9) ◽  
pp. 726
Author(s):  
Wahyu Nirbito ◽  
Muhammad Arif Budiyanto ◽  
Robby Muliadi

This study explains the performance analysis of a propulsion system engine of an LNG tanker using a combined cycle whose components are gas turbine, steam turbine, and heat recovery steam generator. The researches are to determine the total resistance of an LNG tanker with a capacity of 125,000 m3 by using the Maxsurf Resistance 20 software, as well as to design the propulsion system to meet the required power from the resistance by using the Cycle-Tempo 5.0 software. The simulation results indicate a maximum power of the system of about 28,122.23 kW with a fuel consumption of about 1.173 kg/s and a system efficiency of about 48.49% in fully loaded conditions. The ship speed can reach up to 20.67 knots.


1979 ◽  
Author(s):  
L. F. Fougere ◽  
H. G. Stewart ◽  
J. Bell

Citizens Utilities Company’s Kauai Electric Division is the electric utility on the Island of Kauai, fourth largest and westernmost as well as northernmost of the Hawaiian Islands. As a result of growing load requirements, additional generating capacity was required that would afford a high level of reliability and operating flexibility and good fuel economy at reasonable capital investment. To meet these requirements, a combined cycle arrangement was completed in 1978 utilizing one existing gas turbine-generator and one new gas turbine-generator, both exhausting to a new heat recovery steam generator which supplies steam to an existing steam turbine-generator. Damper controlled ducting directs exhaust gas from either gas turbine, one at a time, through the heat recovery steam generator. The existing oil-fired steam boiler remains available to power the steam turbine-generator independently or in parallel with the heat recovery steam generator. The gas turbines can operate either in simple cycle as peaking units or in combined cycle, one at a time, as base load units. This arrangement provides excellent operating reliability and flexibility, and the most favorable economics of all generating arrangements for the service required.


Author(s):  
Donald A. Kolp ◽  
Charles E. Levey

Zorlu Enerji needed 35 MW of reliable power at a stable frequency to maintain constant speed on the spindles producing thread at its parent company’s textile plant in Bursa, Turkey. In December of 1996, Zorlu selected an LM2500+ combined cycle plant to fill its power-generating requirements. The LM2500+ has output of 26,810 KW at a heat rate of 9,735 Kj/Kwh. The combined cycle plant has an output of 35,165 KW and a heat rate of 7,428 Kj/Kwh. The plant operates in the simple cycle mode utilizing the LM2500+ and a bypass stack and in combined cycle mode using the 2-pressure heat recovery steam generator and single admission, 9.5 MW condensing steam turbine. The generator is driven through a clutch by the steam turbine from the exciter end and by the gas turbine from the opposing end. The primary fuel for the plant is natural gas; the backup fuel is naphtha. Utilizing a load bank, the plant is capable of accepting a 12 MW load loss when the utility breaker trips open; it can sustain this loss while maintaining frequency within 1% on the mill load. The frequency stabilizing capability prevents overspeeding of the spindles, breakage of thousands of strands of thread and a costly shutdown of the mill. A description of the equipment, operation and performance illustrates the unique features of this versatile, compact and efficient generating unit.


2007 ◽  
Vol 11 (4) ◽  
pp. 143-156 ◽  
Author(s):  
Kumar Ravi ◽  
Krishna Rama ◽  
Rama Sita

Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.


Author(s):  
Tarek A. Tawfik ◽  
Thomas P. Smith

Retrofitting existing power generation plants by repowering is becoming an attractive option to improve plant performance with less cost. “Hot Windbox Repowering” involves utilizing the hot exhaust gas from a combustion gas turbine and using it as combustion air for an existing fossil-fuel boiler. “Combined Cycle Repowering” or “Full Repowering” involves completely replacing the existing boiler with a combined cycle consisting of a gas turbine(s) and a heat recovery steam generator (HRSG). The existing steam turbine will be used in both repowering scenarios. This paper discusses an engineering study and summarizes the results obtained from repowering an existing heavy-oil / natural gas fired steam power plant in the north east of the United States. The plant consists of a 600 MW boiler and steam turbine. Several engineering studies were considered and evaluated thermodynamically and economically to retrofit such plant. Several options were considered involving different gas turbines, gas turbine combinations, and different repowering methods. The best option is based on retrofitting the unit by a combination of both, hot windbox repowering and combined cycle repowering. The proposed design consists of one gas turbine repowering the windbox of the existing boiler, and a second gas turbine operating in a separate combined cycle configuration with the generated superheated steam tying into the main steam line and expanding in the existing steam turbine. Several heat balances were developed to assist in obtaining meaningful results for this feasibility study. Actual costs were obtained for the gas turbines and heat recovery steam generators (HRSG), as well as installation costs for a more accurate evaluation. The results indicate that the combined output of the repowered unit will generate an additional 295 MW and reduce the heat rate by more than 11 percent at full load and annual average ambient conditions. The estimated capital cost of the project is expected to range from $235 to $245 millions.


Author(s):  
A. I. Zwebek ◽  
P. Pilidis

This paper investigates the possibility of applying a new technique called Gas/Steam Path Analysis (GSPA), that is based on the principles of Gas Path Analysis (GPA), to gas as well as steam turbine plants (as one unit) that are main parts of a combined cycle power plant by way of simulation. In order to facilitate this investigation two pieces of software were developed at Cranfield University. With this technique, it was possible to monitor the major components of the combined cycle, and hence predict the faults that may occur within the cycle beforehand. Faults looked at were, fouling and erosion of gas and steam turbine units, heat recovery steam generator degradation (scaling and/or ashe deposition), and condenser degradation. The obtained results from GSPA calculations of the cases investigated showed that “GSPA” technique can be equally applied to either gas turbine cycle, steam turbine cycle, or to the combination of the two in a form of combined cycle. The procedure, assumptions made, and the results obtained are presented and discussed herein.


2003 ◽  
Vol 125 (3) ◽  
pp. 658-663 ◽  
Author(s):  
A. Zwebek ◽  
P. Pilidis

This is the second paper exploring the effects of the degradation of different components on combined cycle gas turbine (CCGT) plant performance. This paper investigates the effects of degraded steam path components of steam turbine (bottoming) cycle have on CCGT power plant performance. Areas looked at were, steam turbine fouling, steam turbine erosion, heat recovery steam generator degradation (scaling and/or ashes deposition), and condenser degradation. The effect of gas turbine back-pressure on plant performance due to HRSG degradation is also discussed. A general simulation FORTRAN code was developed for the purpose of this study. This program can calculate the CCGT plant design point performance, off-design plant performance, and plant deterioration performance. The results obtained are presented in a graphical form and discussed.


Author(s):  
A. Zwebek ◽  
P. Pilidis

This is the second paper exploring the effects of the degradation of different components on Combined Cycle Gas Turbine (CCGT) plant performance. This paper investigates the effects of degraded steam path components of steam turbine (bottoming) cycle have on CCGT power plant performance. Areas looked at were, steam turbine fouling, steam turbine erosion, heat recovery steam generator degradation (scaling and/or ashes deposition), and condenser degradation. The effect of gas turbine back-pressure on plant performance due to HRSG degradation is also discussed. A general simulation Fortran code was developed for the purpose of this study. This program can calculate the CCGT plant design point performance, off-design plant performance, and plant deterioration performance. The results obtained are presented in a graphical form and discussed.


Author(s):  
Meherwan P. Boyce

The performance analysis of the new generation of Gas Turbines in combined cycle operation is complex and presents new problems, which have to be addressed. The new units operate at very high turbine firing temperatures. Thus variation in this firing temperature significantly affects the performance and life of the components in the hot section of the turbine. The compressor pressure ratio is high which leads to a very narrow operation margin, thus making the turbine very susceptible to compressor fouling. The turbines are also very sensitive to backpressure exerted on them by the heat recovery steam generators. The pressure drop through the air filter also results in major deterioration of the performance of the turbine. The performance of the combined cycle is also dependent on the steam turbine performance. The steam turbine is dependent on the pressure, temperature, and flow generated in the heat recovery steam generator, which in turn is dependent on the turbine firing temperature, and the air mass flow through the gas turbine. It is obvious that the entire system is very intertwined and that deterioration of one component will lead to off-design operation of other components, which in most cases leads to overall drop in cycle efficiency. Thus, determining component performance and efficiency is the key to determining overall cycle efficiency. Thermodynamic modeling of the plant with individual component analysis is not only extremely important in optimizing the overall performance of the plant but in also determining life cycle considerations.