scholarly journals FEA Analysis of Double Tube Heat Exchanger on Variable Baffle Pitch for Optimizing Thermal Efficiency

2020 ◽  
Vol 6 (6) ◽  
pp. 15-28
Author(s):  
Anil Kumar ◽  
Rashmi Dwivedi ◽  
Sanjay Chhalotre

The main objective of this work is to compare different configurations of helical baffles in the cold fluid side of a double tube heat exchanger. For this analysis double pipe heat exchangers are divided into three different domains such as two fluid domains hot fluid in the inner tube and cold fluid in the outer pipe and a solid domain as helical baffles on inner tube of hot fluid. The hot water flows inside the heat exchanger tube, while the cold fluid flows in the outer side in the direction of counter flow. Mass flow rate cold fluid was varied from 0.1 kg/s to 0.3 kg/s while the flow rate in the inner tube i.e. hot water was kept constant at 0.1 kg/s. the inlet temperature of hot fluid taken as 40oC while Cold fluid inlet temperature taken as 15oC. The fluent software is used to calculate the fluid flow and heat transfer in the computational domains. The governing equations are iteratively solved by the finite volume formulation with the SIMPLE algorithm. Results show that that the maximum temperature drop of 10.9 oC for hot fluid and the maximum temperature rise of 11.9 oC for cold fluid are observed at 0.3 kg/sec mass flow rate for double pipe heat exchanger with double helical baffles. It has been also observed that the heat transfer coefficient increasing with the increasing in the mass flow rate of cold fluid. The overall heat transfer coefficients differ significantly by 20.4 % at same mass flow rate, because the considerable difference between heat transfer surface area on the inner and outer side of the tube resulting in a prominent thermal enhancement of the cold fluid.

2008 ◽  
Vol 12 (3) ◽  
pp. 85-90 ◽  
Author(s):  
Rangasamy Rajavel ◽  
Kaliannagounder Saravanan

In this paper, the heat transfer coefficients in a spiral plate heat exchanger are investigated. The test section consists of a plate of width 0.3150 m, thickness 0.001 m and mean hydraulic diameter of 0.01 m. The mass flow rate of hot water (hot fluid) is varying from 0.5 to 0.8 kg/s and the mass flow rate of cold water (cold fluid) varies from 0.4 to 0.7 kg/s. Experiments have been conducted by varying the mass flow rate, temperature, and pressure of cold fluid, keeping the mass flow rate of hot fluid constant. The effects of relevant parameters on spiral plate heat exchanger are investigated. The data obtained from the experimental study are compared with the theoretical data. Besides, a new correlation for the Nusselt number which can be used for practical applications is proposed.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2016 ◽  
Vol 836 ◽  
pp. 102-108
Author(s):  
Mirmanto ◽  
Emmy Dyah Sulistyowati ◽  
I Ketut Okariawan

In the rainy season, in tropical countries, to dry stuffs is difficult. Using electrical power or fossil energy is an expensive way. Therefore, it is wise to utilize heat waste. A device that can be used for this purpose is called radiator. The effect of mass flow rate on pressure drop and heat transfer for a dryer room radiator have been experimentally investigated. The room model size was 1000 mm x 1000 mm x 1000 mm made of plywood and the overall radiator dimension was 360 mm x 220 mm x 50 mm made of copper pipes with aluminium fins. Three mass flow rates were investigated namely 12.5 g/s, 14 g/s and 16.5 g/s. The water temperature at the entrance was increased gradually and then kept at 80°C. The maximum temperature reached in the dryer room was 50°C which was at the point just above the radiator. The effect of the mass flow rate on the room temperature was insignificant, while the effect on the pressure drop was significant. Moreover, the pressure drop decreased as the inlet temperature increased. In general, the radiator is recommended to be used as the heat source in a dryer room.


Author(s):  
Luca Cirillo ◽  
Oronzio Manca ◽  
Lorenzo Marinelli ◽  
Sergio Nardini

In this paper an experimental investigation on forced convection in a compact heat exchanger made up with an aluminum foam plate of 212.5mm × 212.5mm with a thickness of 40 mm and a single array with five circular tubes is presented. The foam has a porosity of 0.93 with 20 pores per inch and the tubes in aluminum have internal and external diameters equal to 9.5 mm and 12.5 mm. The test rig consists of an open air channel and a closed water cycle and the aluminum foam plate is placed inside the channel. The performances of the compact heat exchanger are evaluated for assigned hot water mass flow rate and different hot water inlet temperatures and air mass flow rate. Results are given in terms of heat transfer rates and pressure drops as a function of air velocity and Reynolds numbers. The evaluation of dimensionless, thermal resistance, Colburn factor and Nusselt number is performed for different air mass flow rates and hot water inlet temperatures. The performance evaluation criteria is considered in terms of ratio between the heat transfer rate inside the heat exchanger and the pumping power of the air fan.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


Author(s):  
Dieter Bohn ◽  
Norbert Moritz ◽  
Michael Wolff

In this paper the results of experimental investigations are presented that were performed at the institute’s turbo charger test stand to determine the heat flux between the turbine and the compressor of a passenger car turbo charger. A parametric study has been performed varying the turbine inlet temperature and the mass flow rate. The aim of the analysis is to provide a relation of the Reynolds number at the compressor inlet and the heat flux from the turbine to the compressor with the turbine inlet temperature as the parameter. Thereto, the analysis of the local heat fluxes is necessary which is performed in a numerical conjugate heat transfer and flow analysis which is presented in part I of the paper. Beyond the measurements necessary to determine the operating point of compressor and turbine, the surface temperature of the casings were measured by resistance thermometers at different positions and by thermography. All measurement results were used as boundary conditions for the numerical simulation, i.e. the inlet and outlet flow conditions for compressor and turbine, the rotational speed, the oil temperatures and the temperature distribution on the outer casing surface of the turbo charger. The experimental results show that the total heat flux from turbine to compressor is mainly influenced by the turbine inlet temperature. The increase of the mass flow rate leads to a higher pressure ratio in the compressor so that the compressor casing temperature is increased. Due to the turbo charger’s geometry heat radiation has a small influence on the total heat flux.


2015 ◽  
Vol 62 (4) ◽  
pp. 509-522 ◽  
Author(s):  
R. Dharmalingam ◽  
K.K. Sivagnanaprabhu ◽  
J. Yogaraja ◽  
S. Gunasekaran ◽  
R. Mohan

Abstract Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.


2011 ◽  
Vol 145 ◽  
pp. 129-133 ◽  
Author(s):  
Thanhtrung Dang ◽  
Ngoctan Tran ◽  
Jyh Tong Teng

The study was done both numerically and experimentally on the heat transfer behaviors of a microchannel heat sink. The solver of numerical simulations (CFD - ACE+software package) was developed by using the finite volume method. This numerical method was performed to simulate for an overall microchannel heat sink, including the channels, substrate, manifolds of channels as well as the covered top wall. Numerical results associated with such kinds of overall microchannel heat sinks are rarely seen in the literatures. For cases done in this study, a heat flux of 9.6 W/cm2was achieved for the microchannel heat sink having the inlet temperature of 25 °C and mass flow rate of 0.4 g/s with the uniform surface temperature of bottom wall of the substrate of 50 °C; besides, the maximum heat transfer effectiveness of this device reached 94.4%. Moreover, in this study, when the mass flow rate increases, the outlet temperature decreases; however, as the mass flow rate increases, the heat flux of this heat sink increases also. In addition, the results obtained from the numerical analyses were in good agreement with those obtained from the experiments as well as those from the literatures, with the maximum discrepancies of the heat fluxes estimated to be less than 6 %.