scholarly journals Harmonic Contribution Determination of Multiple Harmonic Sources Based on FastICA in Distribution Network

Keyword(s):  
Author(s):  
Babatope Albert Alabadan ◽  
Oluwaseun Ayodele Ilesanmi ◽  
Femi Samuel Omotayo ◽  
O. Lewis Obidake

2017 ◽  
Author(s):  
D. Brikić

Accent is on determination of appropriate friction factor, and on selection of representative equation for natural gas flow under presented conditions in the network. Calculation of presented looped gas-pipeline network is done according to principles of Hardy Cross method. The final flows were calculated, for known pipes diameters and nodes consumptions while the flow velocities through pipes have to stand below certain values. In optimization problem flows are treated as constant, while the diameters are variables.


2011 ◽  
Vol 22 (No. 6) ◽  
pp. 222-229
Author(s):  
I. Bohačenko ◽  
Z. Kopicová ◽  
I. Zámečníková

The samples, 29 in total, of poultry, rabbit meat, cheese and exotic fruits were taken from the distribution network of Prague. None of the samples was declared as irradiated according to the Decree of the Ministry of Health, CR, No. 133/2004 Sb. The check of their possible exposure to irradiation was made by means of two methods, i.e. the procedure according to EN 1784 (determination of hydrocarbons generated by irradiation using gas chromatography) and the determination of non-bonded o-tyrosine by means of HPLC with electrochemical detection. Neither method brought evidence for the exposure to irradiation, i.e. the purchased foodstuffs concerned were not labelled deceitfully.    


2014 ◽  
Vol 909 ◽  
pp. 428-432 ◽  
Author(s):  
Ioan Sarbu ◽  
Gabriel Ostafe

Distribution networks are an essential part of all water supply systems. Distribution system costs within any water supply scheme may be equal to or greater than 60% of the entire cost of the project. The reliability of supply is much greater in the case of looped networks. The pipe networks have concentrated outflows or uniform outflow along the length of each pipe. In some pipes with variable discharge of a looped distribution network, water velocity could be reversed between its extremities. Thus, it is a water stall point denominated neutral point in which the discharge is null. In this paper a mathematical model for the determination of water stall point location in the pipes with distributed consumption is developed. This model has been implemented in a computer program for PC microsystems. Numerical example will be presented to demonstrate the accuracy and efficiency of the proposed model.