Single exposure double frame particle image velocimeters

Author(s):  
Richard D. Keane ◽  
Ronald J. Adrian ◽  
David K. Ford
Author(s):  
Neng-Yu Zhang ◽  
Terence Wagenknecht ◽  
Michael Radermacher ◽  
Tom Obrig ◽  
Joachim Frank

We have reconstructed the 40S ribosomal subunit at a resolution of 4 nm using the single-exposure pseudo-conical reconstruction method of Radermacher et al.Small (40S) ribosomal subunits were Isolated from rabbit reticulocytes, applied to grids and negatively stained (0.5% uranyl acetate) in a manner that “sandwiches” the specimen between two layers of carbon. Regions of the grid exhibiting uniform and thick staining were identified and photographed twice (magnification 49,000X). The first micrograph was always taken with the specimen tilted by 50° and the second was of the Identical area untilted (Fig. 1). For each of the micrographs the specimen was subjected to an electron dose of 2000-3000 el/nm2.Three hundred thirty particles appearing in the L view (defined in [4]) were selected from both tilted- and untilted-specimen micrographs. The untilted particles were aligned and their rotational alignment produced the azimuthal angles of the tilted particles in the conical tilt series.


1991 ◽  
Vol 65 (02) ◽  
pp. 202-205 ◽  
Author(s):  
Harvey J Weiss ◽  
Vincet T Turitto ◽  
Hans R Baumgartner

SummaryIn order to explore further the mechanism by which glycoprotein GPIIb-IIIa promotes platelet vessel wall interaction, platelet adhesion to subendothelium was studied in an annular chamber in which subendothelium from rabbit aorta was exposed at a shear rate of 2,600 s−1 to blood from patients with thrombasthenia. Perfusions were conducted for each of 5 exposure times (1 ,2,3, 5 and 10 min), and the percent surface coverage of the vessel segment with platelets in the contact (C) and spread (S) stage was determined. Increased values of platelet contact (C) were obtained in thrombasthenia at all exposure times; this finding is consistent with a defect in platelet spreadirg, based on a previously described kinetic model of platelet attachment to subendothelium. According to this model of attachment, increased values of platelet contact (C) at a single exposure time may be indicative of either a defect in spreading (S) or initial contact (C), but multiple exposures will result in increased contact only for defects which are related to defectiye platelet spreading (s).The results obtained over a broad range of exposure times provide more conclusive evidence that GPIIb-IIIa mediates platelet spreading than those previously obtained at single exposure times.


2008 ◽  
Author(s):  
Yuankun Lin ◽  
Ahmad Harb ◽  
Daniel Rodriguez ◽  
Karen Lozano ◽  
Di Xu ◽  
...  

2020 ◽  
Vol 2020 (7) ◽  
pp. 143-1-143-6 ◽  
Author(s):  
Yasuyuki Fujihara ◽  
Maasa Murata ◽  
Shota Nakayama ◽  
Rihito Kuroda ◽  
Shigetoshi Sugawa

This paper presents a prototype linear response single exposure CMOS image sensor with two-stage lateral overflow integration trench capacitors (LOFITreCs) exhibiting over 120dB dynamic range with 11.4Me- full well capacity (FWC) and maximum signal-to-noise ratio (SNR) of 70dB. The measured SNR at all switching points were over 35dB thanks to the proposed two-stage LOFITreCs.


Sign in / Sign up

Export Citation Format

Share Document