Microcomputed Tomography Evaluation of Polymerization Shrinkage of Class I Flowable Resin Composite Restorations

2017 ◽  
Vol 42 (1) ◽  
pp. E16-E23 ◽  
Author(s):  
CS Sampaio ◽  
K-J Chiu ◽  
E Farrokhmanesh ◽  
M Janal ◽  
RM Puppin-Rontani ◽  
...  

SUMMARY The present study aimed to characterize the pattern and volume of polymerization shrinkage of flowable resin composites, including one conventional, two bulk fill, and one self-adhesive. Standardized class I preparations (2.5 mm depth × 4 mm length × 4 mm wide) were performed in 24 caries-free human third molars that were randomly divided in four groups, according to the resin composite and adhesive system used: group 1 = Permaflo + Peak Universal Bond (PP); group 2 = Filtek Bulk Fill + Scotchbond Universal (FS); group 3 = Surefil SDR + XP Bond (SX); and group 4 = Vertise flow self-adhering (VE) (n=6). Each tooth was scanned three times using a microcomputed tomography (μCT) apparatus. The first scan was done after the cavity preparation, the second after cavity filling with the flowable resin composite before curing, and the third after it was cured. The μCT images were imported into three-dimensional rendering software, and volumetric polymerization shrinkage percentage was calculated for each sample. Data were submitted to one-way analysis of variance and post hoc comparisons. No significant difference was observed among PP, FS, and VE. SX bulk fill resin composite presented the lowest values of volumetric shrinkage. Shrinkage was mostly observed along the occlusal surface and part of the pulpal floor. In conclusion, polymerization shrinkage outcomes in a 2.5-mm deep class I cavity were material dependent, although most materials did not differ. The location of shrinkage was mainly at the occlusal surface.

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Ruba M. Mustafa ◽  
Suhad J. Al-Nasrawi ◽  
Abtesam I. Aljdaimi

Biodentine is a calcium silicate cement (CSC) that has been broadly applied in vital pulp therapy. The quality of the Biodentine-composite bond has a significant effect on the longevity of the definitive restoration. The aim of this study is to investigate the shear bond strength (SBS) between Biodentine and composite restoration at different maturation times of Biodentine aged in artificial saliva. Fifteen Biodentine discs were allocated into three groups (n = 5) based on the timeframe of performance of composite restoration: immediate (after 12  min), after 14 days, and after 28 days of Biodentine maturation. Total etch and rinse adhesive system and bulk-fill regular resin composite were used. The shear bond strength and the failure pattern were assessed. One-way ANOVA with the Bonferroni post hoc test was applied for statistical analysis at p < 0.05 . The highest (32.47 ± 8.18 MPa) and the lowest (4.08 ± 0.81 MPa) SBS values were recorded for 14 days and 12 min groups, respectively. Significant statistical differences were reported among the groups, and a high statistically significant difference was found between the immediate group and the other groups. Adhesive failure patterns were evident in all groups. More clinically acceptable bond strength between the Biodentine and overlaid composite restoration is at 14 days after Biodentine maturation. Delaying the coverage of Biodentine later than 14 days may significantly reduce the SBS. Using the artificial saliva as an aging medium may affect the SBS between Biodentine and composite material.


2017 ◽  
Vol 21 (1) ◽  
pp. 24-31 ◽  
Author(s):  
Athanasios Synarellis ◽  
Pantelis Kouros ◽  
Elisabeth Koulaouzidou ◽  
Dimitrios Strakas ◽  
Eugenia Koliniotou-Koumpia

SummaryBackground: The aim of this in vitro study was to compare the degree of microleakage on enamel and dentin margins of class V cavities prepared with either a high-speed drill or an Er,Cr:YSGG laser (2780 nm) and to associate their use with a beveling method for the margin.Method and Materials: Sixty bovine incisors were randomly distributed into three groups. Group 1 (G1) cavities were laser prepared and bur beveled, group 2 (G2) cavities were bur prepared and beveled, while cavities of group 3 (G3) were laser prepared and beveled. Cavities were restored with selective enamel etching, using the same bonding agent and nano-hybrid resin composite for all groups. After thermocycling, microleakage was assessed using a methylene blue dye penetration method.Results: Statistical analysis (Mann-Whitney, Kruskal-Wallis and post-hoc Dunn’s multiple comparison tests) demonstrated significantly higher microleakage for dentin compared to enamel margins in G1. Enamel margin microleakage was found to be significantly higher at G3 compared to G1 (p=0.032) and G2 (p=0.001), while no significant differences were found between G1 and G2 (p=0.850). Regarding dentin margins, G2 group performed significantly better than G1 and G3 (p<<0.001), while there was no significant difference among G1 and G3 scores (p=1.000).Conclusions: The conventional cavity preparation method seems to perform better in terms of microleakage than the Er,Cr;YSGG laser. Laser-prepared cavities could perform better in terms of microleakage if an additional step of enamel bur-beveling is performed prior to restoration.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ádám László Nagy ◽  
Zsolt Tóth ◽  
Tamás Tarjányi ◽  
Nándor Tamás Práger ◽  
Zoltán Lajos Baráth

Abstract Background In this research the biomechanical properties of a bone model was examined. Porcine ribs are used as experimental model. The objective of this research was to investigate and compare the biomechanical properties of the bone model before and after implant placement. Methods The bone samples were divided in three groups, Group 1 where ALL-ON-FOUR protocol was used during pre-drilling and placing the implants, Group 2 where ALL-ON-FOUR protocol was used during pre-drilling, and implants were not placed, and Group 3 consisting of intact bones served as a control group. Static and dynamic loading was applied for examining the model samples. Kruskal–Wallis statistical test and as a post-hoc test Mann–Whitney U test was performed to analyze experimental results. Results According to the results of the static loading, there was no significant difference between the implanted and original ribs, however, the toughness values of the bones decreased largely on account of predrilling the bones. The analysis of dynamic fatigue measurements by Kruskal–Wallis test showed significant differences between the intact and predrilled bones. Conclusion The pre-drilled bone was much weaker in both static and dynamic tests than the natural or implanted specimens. According to the results of the dynamic tests and after a certain loading cycle the implanted samples behaved the same way as the control samples, which suggests that implantation have stabilized the skeletal bone structure.


2006 ◽  
Vol 76 (6) ◽  
pp. 1028-1034 ◽  
Author(s):  
Neslihan Arhun ◽  
Ayca Arman ◽  
Sevi Burçak Çehreli ◽  
Serdar Arıkan ◽  
Erdem Karabulut ◽  
...  

Abstract Objective: To assess microleakage of a tooth-adhesive-bracket complex when metal or ceramic brackets were bonded with a conventional and an antibacterial self-etching adhesive. Materials and Methods: Forty freshly extracted human premolars were randomly assigned to four equal groups and received the following treatments: group 1 = Transbond XT + metal bracket, group 2 = Transbond XT + ceramic bracket, group 3 = Clearfil Protect Bond + ceramic bracket, and group 4 = Clearfil Protect Bond + metal bracket. After photopolymerization, the teeth were kept in distilled water for 1 month and thereafter subjected to thermal cycling (500 cycles). Specimens were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, sectioned and examined under a stereomicroscope, and scored for marginal microleakage for the adhesive-tooth and bracket-adhesive interfaces from incisal and gingival margins. Statistical analysis was accomplished by Kruskal-Wallis test and Mann-Whitney U-test with Bonferroni correction. Results: All groups demonstrated microleakage between the adhesive-enamel and bracket-adhesive interfaces. A significant difference was observed among all groups (P &lt; .05) for the microleakage between the bracket-adhesive interface. Metal brackets exhibited significantly more microleakage than did ceramic brackets between the bracket-adhesive interface with either of the adhesives. Clearfil Protect Bond exhibited results similar to Transbond XT. Clearfil Protect Bond may be a choice of adhesive in bracket bonding because of its antibacterial activity and similar microleakage results with the orthodontic adhesive. Conclusions: Metal brackets cause more leakage between an adhesive-bracket interface, which may lead to lower clinical shear bond strength and white-spot lesions.


Author(s):  
A H A Baazil ◽  
J G G Dobbe ◽  
E van Spronsen ◽  
F A Ebbens ◽  
F G Dikkers ◽  
...  

Abstract Objective This study aimed to compare the necessary scutum defect for transmeatal visualisation of middle-ear landmarks between an endoscopic and microscopic approach. Method Human cadaveric heads were used. In group 1, middle-ear landmarks were visualised by endoscope (group 1 endoscopic approach) and subsequently by microscope (group 1 microscopic approach following endoscopy). In group 2, landmarks were visualised solely microscopically (group 2 microscopic approach). The amount of resected bone was evaluated via computed tomography scans. Results In the group 1 endoscopic approach, a median of 6.84 mm3 bone was resected. No statistically significant difference (Mann–Whitney U test, p = 0.163, U = 49.000) was found between the group 1 microscopic approach following endoscopy (median 17.84 mm3) and the group 2 microscopic approach (median 20.08 mm3), so these were combined. The difference between the group 1 endoscopic approach and the group 1 microscopic approach following endoscopy plus group 2 microscopic approach (median 18.16 mm3) was statistically significant (Mann–Whitney U test, p < 0.001, U = 18.000). Conclusion This study showed that endoscopic transmeatal visualisation of middle-ear landmarks preserves more of the bony scutum than a microscopic transmeatal approach.


2021 ◽  
Author(s):  
KR Kantovitz ◽  
LL Cabral ◽  
NR Carlos ◽  
AZ de Freitas ◽  
DC Peruzzo ◽  
...  

SUMMARY The aim of this in vitro study was to quantitatively evaluate the internal gap of resin composites of high-and low-viscosity used in single- and incremental-fill techniques in Class I cavities exposed to thermal cycling (TC) using optical coherence tomography (OCT). Cavities of 4-mm depth and 3-mm diameter were prepared in 36 third molars randomly distributed into four groups, according to viscosity of restorative resin-based composite (high or low viscosity, all from 3M Oral Care) and technique application (bulk or incremental fill) used (n=9): RC, high-viscosity, incremental-fill, resin-based composite (Filtek Z350 XT Universal Restorative); BF, high-viscosity, bulk-fill, resin-based composite (Filtek One Bulk Fill); LRC, low-viscosity, incremental-fill, resin-based composite (Filtek Z350 XT Flowable Universal Restorative); and LBF, low-viscosity, bulk-fill, resin-based composite (Filtek Flowable Restorative). Single Bond Universal Adhesive system (3M Oral Care) was used in all the experimental groups. The incremental-fill technique was used for RC and LRC groups (2-mm increments), and a single-layer technique was used for BF and LBF groups, as recommended by the manufacturer. The internal adaptation of the resin at all dentin walls was evaluated before and after TC (5000 cycles between 5°C and 55°C) using OCT images. Five images of each restored tooth were obtained. Images were analyzed using ImageJ software that measured the entire length of the gaps at the dentin–restoration interface. The length of gaps (μm) was analyzed using two-way repeated measures ANOVA and the Tukey tests (α=0.05). There was a significant interaction between material types and TC (p=0.006), and a significant difference among all material types (p&lt;0.0001), before and after TC (p&lt;0.0001). Increased internal gaps at the dentin–restoration interface were noticed after TC for all groups. RC presented the lowest value of internal gap before and after TC, while LBF showed the highest values of internal gap after TC. In conclusion, TC negatively affected the integrity of internal gap, whereas high-viscosity, incremental-fill, resin-based composite presented better performance in terms of internal adaptation than low-viscosity, bulk-fill materials in Class I cavities.


2016 ◽  
Vol 10 (02) ◽  
pp. 220-224 ◽  
Author(s):  
Emre Bayram ◽  
Huda Melike Bayram

ABSTRACT Objective: The purpose of this study was to evaluate fracture resistance of teeth with immature apices treated with coronal placement of mineral trioxide aggregate (MTA), bioaggregate (BA), and Biodentine. Materials and Methods: Forty-one freshly extracted, single-rooted human premolar teeth were used for the study. At first, the root length was standardized to 9 mm. The crown-down technique was used for the preparation of the root canals using the rotary ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland) of F3 (30). Peeso reamer no. 6 was stepped out from the apex to simulate an incompletely formed root. The prepared roots were randomly assigned to one control (n = 5) and three experimental (n = 12) groups, as described below. Group 1: White MTA (Angelus, Londrina, Brazil) was prepared as per the manufacturer's instructions and compacted into the root canal using MAP system (Dentsply Maillefer, Ballaigues, Switzerland) and condensed by pluggers (Angelus, Londrina, Brazil). Group 2: The canals were filled with DiaRoot-BA (DiaDent Group International, Canada). Group 3: Biodentine (Septodont, Saint Maur des Fosses, France) solution was mixed with the capsule powder and condensed using pluggers. Instron was used to determine the maximum horizontal load to fracture the tooth, placing the tip 3 mm incisal to the cementoenamel junction. Mean values of the fracture strength were compared by ANOVA followed by a post hoc test. P < 0.05 was considered statistically significant. Results: No significant difference was observed among the MTA, BA, and biodentine experimental groups. Conclusion: All the three materials tested, may be used as effective strengthening agents for immature teeth.


2021 ◽  
Vol 10 (11) ◽  
pp. e77101119381
Author(s):  
Tamara Fernandes de Castro ◽  
Liogi Iwaki Filho ◽  
Amanda Lury Yamashita ◽  
Fernanda Chiguti Yamashita ◽  
Naiara Caroline Aparecido dos Santos ◽  
...  

Objective: This study aimed to evaluate the relations between orbit-related structures and sex, age and skeletal deformities using cone-beam computed tomography (CBCT). Methods: This retrospective study evaluated 216 consecutive CBCT scans of patients, who were divided according to: sex (male, n=105; female, n=111), age (A1: 18-32 years, n=71; A2: 33-47 years, n=78; A3: 48-62 years, n=67), and skeletal deformities (Class I, n=70; Class II, n=75; Class III, n=71). The supraorbital foramen (SOF) location, volume of orbit, optic canal (OC) and infraorbital canal (IOC) were evaluated. Results were analyzed using the Gamma model test. The Tukey-Kramer post-hoc test was used to compare the variables with three factors (p<0.05). Results: The IOC volume showed higher values for male, A3 and class I patients. The SOF location and the orbital volume also showed higher values for male patients. Regarding the volume of CO, it showed higher values ​​for male and class I patients. Conclusions: According to our results, sex has been shown to have a significant influence on orbit-related structures. Age and skeletal deformities also influenced the volume of IOC and OC. These results eventually help the clinical practice, being useful for orbital reconstruction surgeries, anthropological studies, gender identification and identification of susceptibility to pathological conditions related to sexual dimorphism.


2007 ◽  
Vol 77 (4) ◽  
pp. 701-706 ◽  
Author(s):  
Rodney G. Northrup ◽  
David W. Berzins ◽  
Thomas Gerard Bradley ◽  
William Schuckit

Abstract Objective: To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. Materials and Methods: Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT) with a conventional (Orthos) and a self-ligating bracket (Damon 2), respectively. Group 3 used a light-cured primer (Orthosolo) and a light-cured adhesive (Blūgloo) with a self-ligating bracket (Damon 2). The specimens were stored in distilled water at 37°C for 40 ± 2 hours, after which they were debonded and inspected for Adhesive Remnant Index (ARI) scoring. Results: The mean shear bond strength was 15.2 MPa for group 1, 23.2 MPa for group 2, and 24.8 MPa for group 3. A one-way analysis of variance and post hoc Tukey test showed significant differences in bond strength (P &lt; .001) between group 1 and groups 2 and 3 but no significant difference (P &gt; .05) between groups 2 and 3. A Weibull analysis demonstrated that all three groups provided sufficient bond strength with over 90% survival rate at normal masticatory and orthodontic force levels. A Kruskal-Wallis test showed no significant difference (P &gt; .05) in ARI scores among all three groups. Conclusions: All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.


2012 ◽  
Vol 59 (2) ◽  
pp. 57-61 ◽  
Author(s):  
Márcia Thaís Pochapski ◽  
José Laufer Neto ◽  
Jocélia Lago Jassen ◽  
Paulo Vitor Farago ◽  
Fábio André Santos

The aim of this present study was to evaluate the irritative potential of 2 topical anesthetics used in intrapocket anesthesia for periodontal scaling/root planing when applied in subcutaneous tissue of rats. Sixty animals were divided into 4 groups: group 1, saline solution (control); group 2, poloxamer gel (thermosetting vehicle); group 3, lidocaine and prilocaine poloxamer thermosetting gel; group 4: EMLA, a lidocaine and prilocaine dermatological cream. Injections of 2% Evans blue were administrated intravenously into the lateral caudal vein. In order to analyze vascular permeability, the tested substances were injected intradermally. The rats were sacrificed 3, 6, and 9 hours after injection of the substances. The dorsal skin was dissected and removed. The vascular permeability was evaluated by the measurement of area of dye extravasation and the dye was subsequently extracted after immersion in formamide. Statistical analyses were made by ANOVA with Bonferroni's post hoc test and Pearson correlation. The 2 methods to analyze the exudative phase of the inflammatory process showed statistically significant difference among the groups and periods of evaluation (P &lt; .05). Both methods had a significant correlation (P &lt; .0001). Under the tested conditions, the anesthetic agents showed mild initial inflammatory response when implanted in subcutaneous connective tissue.


Sign in / Sign up

Export Citation Format

Share Document