scholarly journals Microleakage beneath Ceramic and Metal Brackets Bonded with a Conventional and an Antibacterial Adhesive System

2006 ◽  
Vol 76 (6) ◽  
pp. 1028-1034 ◽  
Author(s):  
Neslihan Arhun ◽  
Ayca Arman ◽  
Sevi Burçak Çehreli ◽  
Serdar Arıkan ◽  
Erdem Karabulut ◽  
...  

Abstract Objective: To assess microleakage of a tooth-adhesive-bracket complex when metal or ceramic brackets were bonded with a conventional and an antibacterial self-etching adhesive. Materials and Methods: Forty freshly extracted human premolars were randomly assigned to four equal groups and received the following treatments: group 1 = Transbond XT + metal bracket, group 2 = Transbond XT + ceramic bracket, group 3 = Clearfil Protect Bond + ceramic bracket, and group 4 = Clearfil Protect Bond + metal bracket. After photopolymerization, the teeth were kept in distilled water for 1 month and thereafter subjected to thermal cycling (500 cycles). Specimens were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, sectioned and examined under a stereomicroscope, and scored for marginal microleakage for the adhesive-tooth and bracket-adhesive interfaces from incisal and gingival margins. Statistical analysis was accomplished by Kruskal-Wallis test and Mann-Whitney U-test with Bonferroni correction. Results: All groups demonstrated microleakage between the adhesive-enamel and bracket-adhesive interfaces. A significant difference was observed among all groups (P < .05) for the microleakage between the bracket-adhesive interface. Metal brackets exhibited significantly more microleakage than did ceramic brackets between the bracket-adhesive interface with either of the adhesives. Clearfil Protect Bond exhibited results similar to Transbond XT. Clearfil Protect Bond may be a choice of adhesive in bracket bonding because of its antibacterial activity and similar microleakage results with the orthodontic adhesive. Conclusions: Metal brackets cause more leakage between an adhesive-bracket interface, which may lead to lower clinical shear bond strength and white-spot lesions.

2008 ◽  
Vol 78 (6) ◽  
pp. 1089-1094 ◽  
Author(s):  
Tancan Uysal ◽  
Mustafa Ulker ◽  
Sabri Ilhan Ramoglu ◽  
Huseyin Ertas

Abstract Objective: To compare the in vitro microleakage of orthodontic brackets (metal and ceramic) between enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival sides produced by self-etching primer system with that of conventional acid etching and bonding. Materials and Method: Sixty freshly extracted human mandibular premolar teeth were used in this study. The teeth were separated into four groups of 15 teeth each and received the following treatments: Group 1, 37% phosphoric acid gel + Transbond XT liquid primer + stainless steel bracket; Group 2, Transbond Plus Self-Etching Primer (TSEP) + stainless steel bracket; Group 3, 37% phosphoric acid gel + Transbond XT liquid primer + ceramic bracket; Group 4, TSEP + ceramic bracket. After curing, specimens were further sealed with nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-adhesive and bracket-adhesive interfaces from both occlusal and gingival margins. Statistical analyses were performed using Kruskal-Wallis and Mann-Whitney U tests. Results: The gingival sides in all groups exhibited higher microleakage scores compared with those observed in occlusal sides for both adhesive interfaces. Enamel-adhesive interfaces exhibited more microleakage than did the adhesive-bracket interfaces. Brackets bonded with self-etching primer system showed significantly higher microleakage at the enamel-adhesive interface of the gingival side. Conclusions: TSEP causes more microleakage between enamel-adhesive interfaces, which may lead to lower bond strength and/or white-spot lesions.


2006 ◽  
Vol 76 (6) ◽  
pp. 1035-1040 ◽  
Author(s):  
Serdar Arıkan ◽  
Neslihan Arhun ◽  
Ayça Arman ◽  
Sevi Burcak Cehreli

Abstract Objective: To test the null hypotheses that (1) the type of light curing unit used (quartz-tungsten-halogen [QTH] or light-emitting diode [LED]) would not affect the amount of microleakage observed beneath brackets, and (2) the bracket type used (ceramic or metal) would not influence the amount of microleakage observed beneath brackets. Materials and Methods: 40 freshly-extracted human premolars were randomly assigned into 4 bonding groups (n = 10/group): group 1, metal bracket + LED-cured Transbond XT; group 2, ceramic bracket + LED-cured Transbond XT; group 3, metal bracket + QTH-cured Transbond XT; and group 4, ceramic bracket + QTH-cured Transbond XT. The teeth were kept in distilled water for 1 month, and thereafter subjected to 500 thermal cycles. Then, specimens were sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, sectioned, and photographed under a stereomicroscope. Microleakage was scored with regard to the adhesive-tooth interface and the bracket-adhesive interface at both incisal and gingival margins. Statistical analysis was accomplished by Kruskal-Wallis and Mann-Whitney U-tests with Bonferroni correction. Results: Microleakage was observed in all groups. When an LED curing unit was used for adhesive polymerization, ceramic brackets displayed significantly less microleakage than metal brackets in both tooth-adhesive and bracket-adhesive interfaces. When a QTH curing unit was used, ceramic brackets displayed significantly less microleakage than metal brackets in the bracket-adhesive interface in both gingival and incisal margins. Conclusions: Ceramic brackets cured with LED units were the best combination, demonstrating the lowest microleakage scores.


2009 ◽  
Vol 03 (04) ◽  
pp. 314-317
Author(s):  
Nazmiye Donmez ◽  
Hale Ari ◽  
Sema Belli

ABSTRACTObjectives: The aim of this study was to evaluate the effect of storage temperature on bond strength of a self etching primer system to pulp chamber dentin.Methods: SE Bond (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (Kuraray, JAPAN) composite resin were used. Eight extracted caries-free human molar teeth were used. Access cavities were prepared through the pulp chamber, randomly distributed into 4 groups and prepared as follows: Group 1 (Control): SE Primer and SE Bond (SEB) were applied to the pulp chamber dentin according to the manufacturer’s instructions, immediately after the delivery from the manufacturer and then the pulp chamber was restored with a resin restorative material. The primer agent of the following groups was stored in a refrigerator and kept at 4�C. Group 2: restored with SEB, kept at 4°C refrigerator for 1 year, Group 3: restored with SEB kept at 23°C room temperature for 1 year and Group 4: restored with SEB kept at 40°C incubator for 1 year. After 24 hrs the teeth were trimmed for microtensile bond testing and loaded to failure at 1mm/min. Data were analyzed using one-way ANOVA and Duncan test (P<.05).Results: The results indicated that Group 4 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found among the other groups (P>.05).Conclusions: As a result of this study, it was concluded that increasing storing temperature or storing period decreases microtensile bond strength of a SEB system to pulp chamber dentin. (Eur J Dent 2009;3:314-317)


VASA ◽  
2020 ◽  
Vol 49 (4) ◽  
pp. 281-284
Author(s):  
Atıf Yolgosteren ◽  
Gencehan Kumtepe ◽  
Melda Payaslioglu ◽  
Cuneyt Ozakin

Summary. Background: Prosthetic vascular graft infection (PVGI) is a complication with high mortality. Cyanoacrylate (CA) is an adhesive which has been used in a number of surgical procedures. In this in-vivo study, we aimed to evaluate the relationship between PVGI and CA. Materials and methods: Thirty-two rats were equally divided into four groups. Pouch was formed on back of rats until deep fascia. In group 1, vascular graft with polyethyleneterephthalate (PET) was placed into pouch. In group 2, MRSA strain with a density of 1 ml 0.5 MacFarland was injected into pouch. In group 3, 1 cm 2 vascular graft with PET piece was placed into pouch and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. In group 4, 1 cm 2 vascular graft with PET piece impregnated with N-butyl cyanoacrylate-based adhesive was placed and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. All rats were scarified in 96th hour, culture samples were taken where intervention was performed and were evaluated microbiologically. Bacteria reproducing in each group were numerically evaluated based on colony-forming unit (CFU/ml) and compared by taking their average. Results: MRSA reproduction of 0 CFU/ml in group 1, of 1410 CFU/ml in group 2, of 180 200 CFU/ml in group 3 and of 625 300 CFU/ml in group 4 was present. A statistically significant difference was present between group 1 and group 4 (p < 0.01), between group 2 and group 4 (p < 0.01), between group 3 and group 4 (p < 0.05). In terms of reproduction, no statistically significant difference was found in group 1, group 2, group 3 in themselves. Conclusions: We observed that the rate of infection increased in the cyanoacyrylate group where cyanoacrylate was used. We think that surgeon should be more careful in using CA in vascular surgery.


2018 ◽  
Vol 21 (1) ◽  
pp. 26 ◽  
Author(s):  
Hatice Miray Uyan ◽  
Keziban Olcay ◽  
Mutlu Özcan

<p><strong>Objective:</strong> This study was designed to evaluate postoperative pain after endodontic retreatment. <strong>Material and Methods:</strong> Asymptomatic, multi-rooted molar &amp; premolar teeth requiring retreatment with 2–5 mm periapical lesions were included. Seventy-eight teeth were randomly placed in four groups (n=20): single-visit (control, group 1), Ledermix (group 2), metronidazole, ciprofloxacin, minocycline mixture (group 3), calcium hydroxide (group 4). The postoperative pain was recorded using a VAS at 6, 12, 24, and 48 h after retreatment. Statistical evaluation was performed using Two-Way Repeated Measures ANOVA and Tukey test. <strong>Results:</strong> Mild pain occurred in 67.5%, moderate in 30%, and flare-ups in 2.5%, and there was a significant difference between the groups (p&lt;0.01). Significantly lower postoperative pain was observed in TAP and CaOH<sub>2 </sub>groups(p&lt;0.05). In the 6, 12, and 24 h intervals, there was a significant difference in the pain levels (p&lt;0.05). <strong>Conclusion:</strong> TAP and CaOH<sub>2</sub> are effective for reducing postoperative pain after retreatment.</p><p><strong>Keywords</strong></p><p>Intracanal medicaments; Multiple-visit; Postoperative pain; Retreatment; Single-visit.</p>


2009 ◽  
Vol 79 (1) ◽  
pp. 138-143 ◽  
Author(s):  
Sabri Ilhan Ramoglu ◽  
Tancan Uysal ◽  
Mustafa Ulker ◽  
Huseyin Ertas

Abstract Objective: To test the null hypothesis that there is no significant difference between the microleakage of adhesive interferences at the occlusal and gingival margins of both ceramic and metallic brackets bonded with light-cured resin-modified glass ionomer and a conventional adhesive. Materials and Methods: Sixty freshly extracted human maxillary premolar teeth were randomly divided into four groups of 15 teeth each. Metal and ceramic brackets were bonded to groups 1 and 2 with resin-modified glass ionomer adhesive (RMGIA). Metal and ceramic brackets were bonded to group 3 and group 4 with a conventional adhesive (CA) system. A dye-penetration method was used for microleakage evaluation. Microleakage from the occlusal and gingival margins was determined by a stereomicroscope for the enamel-adhesive and bracket-adhesive interfaces. Statistical analysis was performed using the Kruskal-Wallis test and the Mann-Whitney U-test with a Bonferroni correction. Results: The gingival side of all groups exhibited higher microleakage scores compared with the occlusal side for both adhesive interfaces. All bracket and adhesive combinations displayed statistically significant differences in microleakage between the enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival sides of the brackets (P &lt; .001). When the adhesive systems were compared, the RMGIA showed more microleakage than the CA between the different interfaces. Conclusions: The hypothesis is rejected. RMGIA results in more microleakage between enamel-adhesive interfaces.


2017 ◽  
Vol 21 (03) ◽  
pp. 189-197 ◽  
Author(s):  
Vlad Dionisie ◽  
Simona Clichici ◽  
Rodica M. Ion ◽  
Oana O. Danila ◽  
Remus Moldovan ◽  
...  

Several studies have shown that some anti-oxidant natural compounds in combination with photodynamic therapy (PDT) can enhance the effectiveness of treatment. The aim of this study is to evaluate the effect of silymarin (SIL) in combination with 5,10,15,20-tetra-sulphonato-phenyl-porphyrin (TSPP) based photodynamic therapy, on experimental tumors. 30 Wistar rats with Walker carcinosarcoma, were divided into 6 groups: group 0 (control) — control, untreated group; group 1 (TSPP) — one dose of TSPP; group 2 (SIL) — silymarin; group 3 (PDT) — TSPP and irradiation 24 h after; group 4 (SIL[Formula: see text]PDT) — silymarin, TSPP and irradiation 24 h after; group 5 (SIL[Formula: see text]IR) and group 6 (IR) — irradiation and in addition, group 5 received SIL. Silymarin administered before photodynamic therapy decreased the lipid peroxidation ([Formula: see text] < 0.05) and modulated the antioxidant defense in tumor treated with PDT and silymarin suggesting that silymarin administration along with photodynamic therapy has an anti-oxidant effect. The caspase — 8 level and -3 activity increased in PDT and PDT [Formula: see text] SIL groups compared to the control; between the two groups there was a significant difference in term of apoptosis in favor to PDT. In conclusion, silymarin administration inhibited the reactive oxygen species generation and reduced the tumoral cells’ apoptosis, suggesting that natural compound administered before photodynamic therapy did not improve the therapy’s effect.


2020 ◽  
Vol 41 (S1) ◽  
pp. s518-s519
Author(s):  
Dayane Costa ◽  
Roel Castillo ◽  
Lillian Kelly Lopes ◽  
Anaclara Tipple ◽  
Honghua Hu ◽  
...  

Objectives: To evaluate the efficacy of double manual cleaning (DMC) with enzymatic followed by alkaline detergent for removing biofilm on hinged surgical instruments compared to automated cleaning by the washer-disinfector. Methods: Biofilm of Staphylococcus aureus (ATCC 25923) was formed in vitro on hemostatic forceps (Fig. 1). Biofilm-covered forceps were rinsed in distilled water and subjected to one of the following cleaning regimes (n = 5 forceps each): Group 1 forceps were soaked in sterile water for 5 minutes. Group 2-DMC forceps were soaked in enzymatic detergent, brushed 5 times on each face, rinsed with filtrated water (0.2 µm), soaked in alkaline detergent, brushed 5 times each face, rinsed with filtrated water (0.2 µm), and dried with sterile cloth. For group 3-DMC plus hinge inner brushing (n = 5), the forceps were soaked in detergents and brushed as in group 2, including hinge inner brushing (2-mm lumen brush) (Fig. 1). In group 4 (automated cleaning in a washer/disinfector), forceps were prewashed, washed once, washed again, rinsed, thermally rinsed, and dried. After the treatments, forceps were evaluated for microbial load (counting of colony-forming units), residual protein (BCA protein assay kit), and biofilm (scanning electron microscopy). Results: There was no statistically significant differences between the microbial load and protein level contaminating the forceps subjected to DMC (group 2) and the positive control group. The DMC with hinge inner brushing group (group 3) and the automated cleaning group (group 4) demonstrated a significantly reduced microbial load: reduction averages of 2.8 log 10 (P = .038) and 7.6 log10 (P ≤ .001), respectively. The protein level remaining on the forceps also significantly decreased: 2.563 μg (P = .016) and 1,453 μg (P = .001), respectively, compared to the positive control group. There was no statistically significant difference between DMC with hinge inner brushing and automated cleaning (groups 3 and 4) for all of the tests performed. None of the cleaning methods completely removed biofilm and/or soil from the forceps hinge internal region (Fig. 1). Conclusions: Automated cleaning had the best efficacy for removing biofilm. However, DMC with hinge inner brushing was an acceptable alternative cleaning method for sterilizing service units with only manual cleaning available, as is the case in most low- and middle-income countries. Neither automated nor any manual cleaning regimes were able to completely remove biofilm and soil from the forceps hinged area, and the amount of protein left after automated and DMC plus hinge brushing was higher than the recommended. Cleaning is the most important step for the reprocessing of reusable medical devices; thus, efforts must be undertaken to improve cleaning in different social and economic realities and scenarios.Funding: This study was supported by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – CAPES.Disclosures: None


2021 ◽  
Vol 14 (4) ◽  
pp. 1508-1513
Author(s):  
Ibraheem F Alshiddi

In order to assess the influence of finishing and polishing on the surface brightness and color stability of the ceramic veneer, fifty specimens were fabricated with 10 mm diameter and 2 mm thickness using IPS E-Max Ceramic. After glazing, 10 specimens were untouched as control group, and the other 40 specimens were abraded using 125µm diamond bur to create surface roughness. Forty specimens were divided into four groups (n=10), in group 1: specimens were finished using diamond point, in group 2 specimens’ surface was polished with a polishing kit, Group 3: Each specimen surface was polished with the polishing kit as in protocol 2 and was polished a polishing past and group 4 Each specimen was glazed by heating at 621℃ for 3 minutes followed by a temperature increase of 83℃/min up to 918℃ for 30 seconds. Color measurement was performed using spectrophotometer. Color stability data were analyzed using two-way ANOVA and Tukey’s HSD test (α=0.05). For Ra values, paired-samples t-tests were used to analyze the data and compare groups. The change in L and E showed a significant difference among the study groups; (group 1, group 2, group 3 and group 4) with respect to three variables L, a and b. A significant difference was noted when compared each group with the control; however, only group 2 showed a significant difference from group 4; the remaining groups demonstrated similar findings for all three variables. The study displayed a significant impact of the finishing and polishing technique on the surface brightness and color stability of ceramic restoration. However, it was evident that combination of two or three polishing techniques which includes polish kit and glaze enhances the surface finish and adds color stability by alternating the yellow – blue axis (increase in b) and red- green axis (decrease in a).


Author(s):  
Abdurrahman Pirinç ◽  
Abdullah Özbilgin ◽  
Oğuzhan Kahraman ◽  
Esad Sami Polat

In this study, nutritional values of silages made from seed pumpkin residues were investigated. Pumpkin residues collected from Konya region were put into silo in vacuum sacks with various additives. As additives, straw, inoculant containing lactic acid bacteria or a mixture of both in certain proportions were used. After the silos were opened, their pH was determined and then samples were taken to determine the essential fatty acid compositions and nutrient analyses were done. Natural pumpkin (Group 1), natural pumpkin + inoculant (100ppm) (Group 2), withered pumpkin + 15% straw (Group 3), withered pumpkin + 15% straw + inoculant (100ppm) (Group 4) such that the fourth group is formed. Dry matter values of pumpkin groups are Group 1 7.89%, Group 2 6.62%, Group 3 12.22% and Group 4 12.25% respectively. Their pH is 3.78 in Group 1, 3.71 in Group 2, 3.86 in Group 3 and 3.82 in Group 4. The crude protein ratio in the experimental groups was determined in the highest Group 2 (14.97%) and the lowest in Group 3 (10.56%). NDF rate was determined in the highest group 4 (49.74%) and the lowest in Group 2 (28.51%). In addition, the highest ADF rate was determined in Group 4 (37.91%) and the lowest in Group 2 (24.90%). There was a statistically significant difference between the research groups in terms of ethanol content. Acetic acid and propionic acid content was found statistically significant between groups. As a result, when the pumpkin residues are silaged, it can be used as feed material in animal feeding. In addition, it can be said that pumpkin residues can be evaluated in different areas in the high amount of Ethanol content resulting from silage production.


Sign in / Sign up

Export Citation Format

Share Document