scholarly journals Effect of the C-factor and Dentin Preparation Method in the Bond Strength of a Mild Self-etch Adhesive

2009 ◽  
Vol 34 (4) ◽  
pp. 452-459 ◽  
Author(s):  
M. S. M. Marques ◽  
S. Kenshima ◽  
A. Muench ◽  
R. Y. Ballester ◽  
L. E. Rodrigues Filho

Clinical Relevance A course cut carbide bur should be avoided prior to a mild self-etch adhesive, because it adversely affected bond strength. In contrast, a fine cut carbide bur provided the best combination: high bond strength with low variability, which suggests more reliable bond strength performance.

2010 ◽  
Vol 35 (6) ◽  
pp. 618-623 ◽  
Author(s):  
Y-E. Chang ◽  
D-H. Shin

Clinical Relevance In order to secure high bond strength in clinical practice, 2% chlorhexidine application after etching with 37% phosphoric acid is the recommended procedure.


10.2341/07-42 ◽  
2008 ◽  
Vol 33 (1) ◽  
pp. 79-88 ◽  
Author(s):  
A. D. Loguercio ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
R. T. Patzlaff ◽  
...  

Clinical Relevance The effect of surface preparation was adhesive-dependent. Improvements in resin-enamel bond strength after enamel preparation were observed only for AdheSE and Optibond Solo plus Self-Etch Primer. Among the self-etch systems, mild, self-etch Clearfil SE Bond showed the highest bond strength values. No degradation of resin-enamel bonds was observed after 12 months of water storage, regardless of the adhesive tested.


Author(s):  
J. Wei ◽  
S. S. Deng ◽  
C. M. Tan

Silicon-to-silicon wafer bonding by sol-gel intermediate layer has been performed using acid-catalyzed tetraethylthosilicate-ethanol-water sol solution. High bond strength near to the fracture strength of bulk silicon is obtained at low temperature, for example 100°C. However, The bond efficiency and bond strength of this intermediate layer bonding sharply decrease when the bonding temperature increases to elevated temperature, such as 300 °C. The degradation of bond quality is found to be related to the decomposition of residual organic species at elevated bonding temperature. The bubble generation and the mechanism of the high bond strength at low temperature are exploited.


10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.


1962 ◽  
Vol 35 (4) ◽  
pp. 1060-1062
Author(s):  
A. I. Yakubchik ◽  
S. Ya Grilikhes ◽  
B. I. Tikhomirov ◽  
V. S. Purlova

Abstract The adhesive composition based on hydrogenated unbranched 1,4-polybutadiene gives a high bond strength between polyethylene and brass, and brass-plated metal, and rubber.


2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Rihong Cao ◽  
Wenyu Tang ◽  
Hang Lin ◽  
Xiang Fan

Binary-medium specimens were fabricated using the particle flow code, and the shear strength, dilatancy, and failure behavior of the binary-medium specimens with different bond strength ratios (0.25, 0.5, 0.75, and 1.0) under different normal stresses were studied. Numerical results show that the bond strength ratio and normal stresses considerably influence the shear strengths of binary-medium interface. Shear strength increases as the bond strength ratio and normal stress increase. The dilation of interfaces with high bond strength ratios is more evident than those of interfaces with lower bond strength ratios, and the curves for the high bond strength ratio exhibit remarkable fluctuations during the residual stage. At increased normal stress and bond strength ratio, the peak dilation angle shows decreasing and increasing trends successively. In this study, the specimens exhibited three kinds of failure modes. In mode II, the sawtooth experienced shear failure, but some tensile cracks appeared on the interface of the binary-medium. In mode III, no sawtooth was cut off, indicating tensile failure on the interface. At a low bond strength ratio, damage or failure is mostly concentrated in the upper part of the model. Failure parts gradually transfer to the lower part of the model when the bond strength ratio and normal stress increase. Furthermore, evident tensile cracks occur on the interface. When the bond strength ratio reaches 1.0, the failure mode of the specimen gradually transforms from sheared-off failure to chip-off failure. The number of microcracks in the specimens indicates that the lower the bond strength ratio, the more severe the damage on the specimens.


2020 ◽  
Vol 165 ◽  
pp. 05015
Author(s):  
Ji Xiu Zhang ◽  
Ye Zhang ◽  
Ji Kang Liu ◽  
Yuan Chao Miao ◽  
Sai Hong Duan

In this paper, a new early strength tile adhesive is prepared by using α- high strength gypsum and its properties are discussed. The research methods refer to relevant Chinese standards. The results show that the tensile bond strength of the adhesive can reach 0.6 MPa in one day and 1.5 MPa in 7 days, which is close to 80% of 28-day strength. It is indicating that the adhesive has high bond strength, rapid strength development, and high dimensional stability. It effectively solves the problems that the traditional cement-based tile adhesive is prone to hollowing, falling off, and cracking. Additionally, no interface treatment is required during the using process of this gypsum-based adhesive.


2011 ◽  
Vol 391-392 ◽  
pp. 807-811
Author(s):  
Fang Liu ◽  
Zhi Bin Zhang ◽  
Ling Ling Xu ◽  
Ming Shu Tang

The epoxy resin based repairing material(REM) is suitable for repairing cracks and holes in concrete or broken concrete due to its high bond strength and high durability. The compressive strength and flexile strength are 76.4MPa and >12.5MPa at 28d, and the retest strength still remain 73.4MPa and >12.5MPa respectively. The fracture location of cement mortar specimen bonded by RME is at cement mortar, that is, the bond strength between REM and cement mortar is more than mortar itself. The compressive strength of RME keeps 93.3% under ultraviolet light radiation (Peak Value 308nm, 49.5 W/m2) for 1700h.


2009 ◽  
Vol 34 (6) ◽  
pp. 716-724 ◽  
Author(s):  
S. Wei ◽  
Y. Shimada ◽  
A. Sadr ◽  
J. Tagami

Clinical Relevance Double-application enhanced the hardness of bonding layer and resin-dentin interface for all the adhesives used; however, it only improved the bond strength to dentin for some of the single-step self-etch adhesives.


Sign in / Sign up