scholarly journals Simple correlations for bubble columns and draft tube airlift reactors with dilute alcohol solutions

2009 ◽  
pp. 183-192
Author(s):  
Ivana Sijacki ◽  
Radmilo Colovic ◽  
Milenko Tokic ◽  
Predrag Kojic

Simple empirical correlations were developed to predict gas holdup, liquid circulation time, downcomer liquid velocity and volumetric mass transfer coefficient in dilute alcohol solutions in bubble columns and draft tube airlift reactors with single orifice sparger. Also, new experiments were conducted with diluted alcohol solutions to n-octanol, expanding the experimental data from C1 up to C8. The proposed empirical correlations include, beside the superficial gas velocity, the alcohol chain length as the only factor to characterize the liquid phase. The suggested correlations have shown good agreement between the calculated and the experimental data.

2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Shaobai Li ◽  
Siyuan Huang ◽  
Jungeng Fan

In this study, the gas holdup of bubble swarms in shear-thinning fluids was experimentally studied at superficial gas velocities ranging from 0.001 to 0.02 m·s−1. Carboxylmethyl cellulose (CMC) solutions of 0.2 wt%, 0.6 wt%, and 1.0 wt% with sodium dodecyl sulfate (SDS) as the surfactant were used as the power-law (liquid phase), and nitrogen was used as the gas phase. Effects of SDS concentration, rheological behavior, and physical properties of the liquid phase and superficial gas velocity on gas holdup were investigated. Results indicated that gas holdup increases with increasing superficial gas velocity and decreasing CMC concentration. Moreover, the addition of SDS in CMC solutions increased gas holdup, and the degree increased with the surfactant concentration. An empirical correlation was proposed for evaluating gas holdup as a function of liquid surface tension, density, effective viscosity, rheological property, superficial gas velocity, and geometric characteristics of bubble columns using the experimental data obtained for the different superficial gas velocities and CMC solution concentrations with different surfactant solutions. These proposed correlations reasonably fitted the experimental data obtained for gas holdup in this system.


SPE Journal ◽  
2020 ◽  
Vol 25 (05) ◽  
pp. 2508-2520
Author(s):  
Mobina Mohammadikharkeshi ◽  
Ramin Dabirian ◽  
Ram S. Mohan ◽  
Ovadia Shoham

Summary A novel experimental and theoretical study on slug dissipation in a horizontal enlarged impacting tee-junction (EIT) is carried out. Both flowing-slug injection and stationary-slug injection into the EIT are studied, and the effects of inlet slug length and liquid-phase fluid properties on the slug dissipation in the EIT are investigated. A total of 161 experimental data are acquired for air-water and air-oil flow. The flowing-slug data (with a horizontal inlet) show that the slug dissipation length increases with increasing mixture velocity, demonstrating a nonlinear trend with a steeper slope at lower mixture velocities. The effect of superficial gas velocity on the slug dissipation length is more pronounced compared with the effect of superficial liquid velocity. For stationary-slug injection into the EIT (with a 5° upward inclined inlet), the injected slug lengths vary between 40d to 100d (d is the inlet diameter). The data reveal that, when increasing the superficial gas velocity or the inlet slug size, the dissipation length in the EIT branches increases. For this case, the ratio of the slug dissipation length to the inlet slug length is higher for air-water compared with air-oil. A slug dissipation model is developed using the slug-tracking approach, which is based on the flow mechanisms of liquid shedding at the back of the slug and liquid drainage and penetration of bubble turning at the front of the slug. These phenomena result in different translational velocities at the back and the front of the slug, which result in the dissipation of the slug body. Evaluation of model predictions against the acquired experimental data shows an average absolute relative error of less than 11%.


2005 ◽  
Vol 70 (11) ◽  
pp. 1363-1371 ◽  
Author(s):  
Ljubisa Nikolic ◽  
Vesna Nikolic ◽  
Vlada Veljkovic ◽  
Dejan Skala

The influence of the geometry of a reciprocating plate column (diameter), superficial gas velocity, vibration intensity and content of the solid phase in the column on the gas hold-up in a three phase column (G-L-S) were investigated in this study. For comparison, the gas hold-up was also analyzed in a gas-liquid system (G-L) in the same type of column. Good agreement between the experimentally determined values of the gas hold-up and those calculated on the basis of the derived correlation for the G-L and G-L-S system was obtained.


Geofluids ◽  
2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Zilong Liu ◽  
Yubin Su ◽  
Ming Lu ◽  
Zilong Zheng ◽  
Ruiquan Liao

Churn flow commonly exists in the pipe of heavy oil, and the characteristics of churn flow should be widely understood. In this paper, we carried out air and viscous oil two-phase flow experiments, and the diameter of the test section is 60 mm. The viscosity range of the oil was 100~480 mPa·s. Based on the measured liquid holdup and pressure drop data of churn flow, it can be concluded that, due to the existence of liquid film backflow, positive and negative frictional pressure drop can be found and the change of frictional pressure drop with the superficial gas velocity is related to superficial liquid velocity. With the increase of viscosity, the change rate of frictional pressure drop increases with the increase of the superficial gas velocity. Combining our previous work and the Taitel model, we proposed a new pressure drop model for viscous oil-air two-phase churn flow in vertical pipes. By comparing the predicted values of existing models with the measured pressure drop data, the proposed model has better performance in predicting the pressure drop.


2011 ◽  
Vol 396-398 ◽  
pp. 639-647
Author(s):  
Zhi Yuan Shen ◽  
Li Jun Yang ◽  
Meng Xi Liu ◽  
Chun Xi Lu ◽  
Xiao Na Liu

The hydrodynamics in a gas-solid draft tube-lifted air-loop reactor (GSALR) was investigated systematically using experimental measurements. To demonstrate the gas-solid flow pattern, the upward particle velocity, downward particle velocity and time-averaged particle velocity in four regions of the GSALR were measured by optical fiber probe under different superficial gas velocities. The experimental results show that the downward particle velocity distributes uniformly along the radius in the four regions, but the radial distributions of upward particle velocity and time-averaged particle velocity are core-annulus or heterogeneous structure in the three regions (distributor affect region, draft tube, gas-solid diffluence region), which have the common feature of aggregative fluidization occurred in normal fluidized beds. The operating condition such as superficial gas velocity in draft tube has different effects on the radial distributions of upward particle velocity, downward particle velocity and time-averaged particle velocity in each region. Analysis of the distributions of upward particle velocity, downward particle velocity and time-averaged particle velocity leads to suggestions regarding optimization of the design and provides further theoretical basis for industry application of GSALR.


1999 ◽  
Vol 121 (2) ◽  
pp. 86-90 ◽  
Author(s):  
C. Kang ◽  
W. P. Jepson ◽  
M. Gopal

The effect of drag-reducing agent (DRA) on multiphase flow in upward and downward inclined pipes has been studied. The effect of DRA on pressure drop and slug characteristics such as slug translational velocity, the height of the liquid film, slug frequency, and Froude number have been determined. Experiments were performed in 10-cm i.d., 18-m long plexiglass pipes at inclinations of 2 and 15 deg for 50 percent oil-50 percent water-gas. The DRA effect was examined for concentrations ranging from 0 to 50 ppm. Studies were done for superficial liquid velocities between 0.5 and 3 m/s and superficial gas velocities between 2 and 10 m/s. The results indicate that the DRA was effective in reducing the pressure drop for both upflow and downflow in inclined pipes. Pressure gradient reduction of up to 92 percent for stratified flow with a concentration of 50 ppm DRA was achieved in ±2 deg downward inclined flow. The effectiveness of DRA for slug flow was 67 percent at a superficial liquid velocity of 0.5 m/s and superficial gas velocity of 2 m/s in 15 deg upward inclined pipes. Slug translational velocity does not change with DRA concentrations. The slug frequency decreases from 68 to 54 slugs/min at superficial liquid velocity of 1 m/s and superficial gas velocity of 4 m/s in 15 deg upward inclined pipes as the concentration of 50 ppm was added. The height of the liquid film decreased with the addition of DRA, which leads to an increase in Froude number.


1980 ◽  
Vol 102 (4) ◽  
pp. 441-445 ◽  
Author(s):  
Kaichiro Mishima ◽  
Mamoru Ishii

A criterion for the onset of a slug flow in a horizontal duct is derived theoretically. A potential flow analysis is carried out by considering waves of finite amplitude. The stability criterion is obtained by introducing the wave deformation limit and the “most dangerous wave” concept in the stability analysis. The present theoretical criterion for slug formation shows very good agreement with a large number of experimental data and with some empirical correlations.


Author(s):  
S. Dhanasekaran ◽  
T. Karunanithi

This investigation reports the experimental and theoretical results carried out to evaluate the volumetric mass transfer coefficient (kLa) in a novel hybrid rotating and reciprocating perforated plate bubble column. Countercurrent condition is performed. kLa is studied by the absorption of oxygen from air into deoxygenated water at room temperature (27 ± 1°C). Effects of agitation level, superficial gas velocity, superficial liquid velocity and plate spacing on kLa were analyzed and found to be significant. With an increase in agitation level at a constant superficial gas and liquid velocities, the breakage process of gas bubbles starts to be more pronounced and intensive oxygen mass transfer occurs. Hence, kLa increases sharply. kLa increases with an increase in superficial gas velocity, due to higher gas holdup and the enhanced breakup of bubbles. Similarly, kLa increases with an increase in superficial liquid velocity and the effect is found to be significant. When plate spacing is decreased (by increasing the number of plates), it is observed that the kLa increases at higher superficial gas velocity and agitation level. Correlation is developed for the determination of kLa and found to concur with experimental results. This correlation can be used for the determination of kLa for this hybrid column with 95% accuracy within the range of variables investigated in this present study.


2008 ◽  
Vol 130 (4) ◽  
Author(s):  
Antonio Reinoso ◽  
Luis E. Gomez ◽  
Shoubo Wang ◽  
Ram S. Mohan ◽  
Ovadia Shoham ◽  
...  

This study investigates theoretically and experimentally the slug damper as a novel flow conditioning device, which can be used upstream of compact separation systems. In the experimental part, a 3 in. ID slug damper facility has been installed in an existing 2 in. diameter two-phase flow loop. This flow loop includes an upstream slug generator, a gas-liquid cylindrical cyclone (GLCC©, ©The University of Tulsa, 1994) attached to the slug damper downstream and a set of conductance probes for measuring the propagation of the dissipated slug along the damper. Over 200 experimental runs were conducted with artificially generated inlet slugs of 50 ft length (Ls/d=300) that were dumped into the loop upstream of the slug damper, varying the superficial liquid velocity between 0.5 ft/s and 2.5 ft/s and superficial gas velocity between 10 ft/s and 40 ft/s (in the 2 in. inlet pipe) and utilizing segmented orifice opening heights of 1 in., 1.5 in., 2 in., and 3 in. For each experimental run, the measured data included propagation of the liquid slug front in the damper, differential pressure across the segmented orifice, GLCC liquid level, GLCC outlet liquid flow, and static pressure in the GLCC. The data show that the slug damper/GLCC system is capable of dissipating long slugs, narrowing the range of liquid flow rate from the downstream GLCC. Also, the damper capacity to process large slugs is a strong function of the superficial gas velocity (and mixture velocity). The theoretical part includes the development of a mechanistic model for the prediction of the hydrodynamic flow behavior in the slug damper. The model enables the predictions of the outlet liquid flow rate and the available damping time, and in turn the prediction of the slug damper capacity. Comparison between the model predictions and the acquired data reveals an accuracy of ±30% with respect to the available damping time and outlet liquid flow rate. The developed model can be used for design of slug damper units.


Author(s):  
Dhanasekaran S ◽  
Karunanithi T

This investigation reports on the experimental and theoretical investigation carried out to evaluate the bubble diameter and effective interfacial area in a novel Hybrid Rotating and Reciprocating Perforated Plate Bubble Column. Air-water system is used in this investigation. Countercurrent mode is employed. The effects of agitation level, superficial gas velocity and superficial liquid velocity on the bubble size distribution are studied. The mean bubble diameter is predicted using photographic technique. A simple correlation is developed for the determination of mean bubble diameter. It is found that the mean bubble diameter values for hybrid column are 1.8 to 2.5 times smaller when compared with conventional reciprocating plate column. The interfacial area is calculated based on the experimental results of the gas holdup and bubble diameter. Effects of agitation level, superficial gas velocity, superficial liquid velocity and plate free area on the interfacial area have been investigated. Correlations are developed for the determination of interfacial area for both mixer-settler and emulsion regions. It could be noted that the interfacial area for the hybrid column is 3 to 6 times higher in both mixer-settler region and emulsion region than that of conventional reciprocating plate column which is quite large.


Sign in / Sign up

Export Citation Format

Share Document