scholarly journals Fungal colonization of air-conditioning systems

2008 ◽  
Vol 60 (2) ◽  
pp. 201-206 ◽  
Author(s):  
Milica Ljaljevic-Grbic ◽  
Jelena Vukojevic ◽  
M. Stupar

Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

Author(s):  
S. N. Osipov ◽  
A. V. Zakharenko ◽  
E. M. Shirokova

The increase of average outdoor temperatures and their fluctuations over the past 20 years (as evidenced by the records of summer temperatures in our country) has significantly increased the need for air conditioning premises where people are present for a long time, especially when they are crowded (shops, entertainment halls, classrooms, etc.). The air conditioning process is quite energy-intensive, but the growth of well-being in many republics of the former USSR, as well as the increasing complexity of the physiological adaptation of the human body to rising outdoor temperatures make it possible (and at the same time necessary) to implement these systems on a large scale. It is important to take into account that electricity prices are currently maintained at a high level for homeowners, and in the coming years the prices will only grow. Therefore, the development of new ways of significant increase of the energy efficiency of the indoor air conditioning process is of a great interest. One of these methods is the use of laminar (or close to them) moving layers of conditioned air in a limited area of work or rest of people. Such a zone, about 1.0‒1.2 m height from a floor in each apartment is, e.g., living rooms (bedroom) in which standard temperature conditions are created by means of simple air supplying and air intake devices. In the case of sedentary work of people, the height of such a zone of conditioned air should be increased to 1.3‒1.5 m. It has already been established that the use of laminar (or close to them) air flows allows to reduce the power consumption by two or more times due to significantly reduced heat exchange with the surrounding heated surfaces. Besides, the simplicity of such systems ought to be noted. In particular, in conditions of modern systems of control and management of air conditioning, the "duties" of consumers include only the installation on the control device of the initial data relating directly to the required parameters of the microclimate. At the same time, it should be noted that there is currently no complete scientific and technical description of aerodynamic and heat exchange processes in the air conditioning zone. Even in modern conditions for countries with a sharply continental climate (Russia, Kazakhstan, etc.), the problem is the choice of the type of air conditioner for its effective use in hot periods of summer. In general, it can be noted that all the problems of energy-efficient use of air conditioners must find a comprehensive solution.


2019 ◽  
Vol 11 (4) ◽  
pp. 1036 ◽  
Author(s):  
Beom-Jun Kim ◽  
Junseok Park ◽  
Jae-Weon Jeong

The main objective of this study is to investigate the indoor air quality enhancement performance of two different liquid desiccant and evaporative cooling-assisted air conditioning systems, such as the variable air volume (VAV) system with the desiccant-enhanced evaporative (DEVap) cooler, and the liquid desiccant system with an indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS), compared with the conventional VAV system. The transient simulations of concentration variations of carbon dioxide (CO2), coarse particles, and fine particles (PM10 and PM2.5) in a model office space served by each system were performed using validated system models that were found in the literature. Based on the hourly thermal loads of the model space predicted by the TRNSYS 18 program, each air conditioning system was operated virtually using a commercial equation solver program (EES). The results indicated that the LD-IDECOAS provided the lowest annual indoor CO2 concentration among all the systems considered in this research, while the VAV system with DEVap cooler exceeded the threshold concentration (i.e., 1000 ppm) during the cooling season (i.e., July, August, and September). For the indoor particulate contaminant concentrations, both liquid desiccant and evaporative cooling-assisted air conditioning systems indicated lower indoor PM2.5 and PM10 concentrations compared with the reference system. The LD-IDECOAS and the VAV with a DEVap cooler demonstrated 33.3% and 23.5% lower annual accumulated indoor PM10 concentrations than the reference system, respectively. Similarly, the annual accumulated indoor PM2.5 concentration was reduced by 16% using the LD-IDECOAS and 17.1% using the VAV with DEVap cooler.


2019 ◽  
Vol 7 (12) ◽  
pp. 674
Author(s):  
Xavier Libert ◽  
Camille Chasseur ◽  
Ann Packeu ◽  
Fabrice Bureau ◽  
Nancy H. Roosens ◽  
...  

Today, indoor air pollution is considered a public health issue. Among the impacting pollutants, indoor airborne fungi are increasingly highlighted. Most of the monitoring protocols are culture-based, but these are unable to detect the uncultivable and/or dead fraction or species suppressed by fast-growing fungi, even though this fraction could impact health. Among the contaminants suspected to be part of this fraction, Exophiala jeanselmei is an interesting case study. Known to be pathogenic, this black yeast grows in humid environments such as air-conditioning systems, where it has been previously detected using classical culture-based methods. However, until now, this fungus was never detected in indoor air in contact with these air-conditioning systems. This study shows the first detection of E. jeanselmei in indoor air collected from offices in contact with contaminated air-conditioning reservoirs. While its presence in indoor air could not be demonstrated with culture-based methods, it was found by real-time PCR and massive parallel sequencing. The latter also allowed obtaining a broader view on the fungal diversity in the tested samples. Similar approaches were applied on water samples collected from the conditioning reservoirs to trace the source of contamination. The comparison of results obtained with both methods confirmed that the molecular tools could improve indoor air monitoring, especially of dead and/or uncultivable contaminants or when competition between species could occur.


2006 ◽  
Vol 27 (1) ◽  
pp. 44-47 ◽  
Author(s):  
F. Perdelli ◽  
M. L. Cristina ◽  
M. Sartini ◽  
A. M. Spagnolo ◽  
M. Dallera ◽  
...  

Objectives.To assess the degree of fungal contamination in hospital environments and to evaluate the ability of air conditioning systems to reduce such contamination.Methods.We monitored airborne microbial concentrations in various environments in 10 hospitals equipped with air conditioning. Sampling was performed with a portable Surface Air System impactor with replicate organism detection and counting plates containing a fungus-selective medium. The total fungal concentration was determined 72-120 hours after sampling. The genera most involved in infection were identified by macroscopic and microscopic observation.Results.The mean concentration of airborne fungi in the set of environments examined was 19 ± 19 colony-forming units (cfu) per cubic meter. Analysis of the fungal concentration in the different types of environments revealed different levels of contamination: the lowest mean values (12 ± 14 cfu/m3) were recorded in operating theaters, and the highest (45 ± 37 cfu/m3) were recorded in kitchens. Analyses revealed statistically significant differences between median values for the various environments. The fungal genus most commonly encountered was Penicillium, which, in kitchens, displayed the highest mean airborne concentration (8 ± 2.4 cfu/m3). The percentage (35%) of Aspergillus documented in the wards was higher than that in any of the other environments monitored.Conclusions.The fungal concentrations recorded in the present study are comparable to those recorded in other studies conducted in hospital environments and are considerably lower than those seen in other indoor environments that are not air conditioned. These findings demonstrate the effectiveness of air-handling systems in reducing fungal contamination.


2014 ◽  
Vol 672-674 ◽  
pp. 54-60 ◽  
Author(s):  
Ting Xiang Jin ◽  
Xiao Feng Xu

As coal, oil, natural gas and other non-renewable energy consumption and increasing energy demand, the utilization of solar energy as a new energy is greatly enhanced. In this work, a grid connected photovoltaic solar air conditioning system is designed, mainly comprised of solar panel, controller, inverter, room air conditioner and other parts. Air conditioning systems rely mainly on solar photovoltaic power; achieve the effect of energy conservation and environmental protection. The experimental result indicates that the system can achieve stable operation and the utilization of solar energy driving air conditioning system to save electricity. This air conditioning system is compared with the ordinary air conditioning system, SEER can increase 10.6 ~ 29.4%, HSPF can increase 6.25 ~ 18.5%.


Author(s):  
A. Anthony Adeyanju ◽  
K. Manohar

Thermoelectric devices use the Peltier effect which creates a heat flux between the junctions of two different types of materials. The thermoelectric module also referred to as a heat pump transfers heat from one side to the other when a DC current is applied. This study carried out the theoretical and experimental analysis of a thermoelectric air conditioning system. A prototype thermoelectric air conditioner of 286 W cooling capacity was built and a testing enclosure made from plywood and Styrofoam was also constructed in order to validate the theoretical result with an experimentation. It was discovered that thermoelectric air conditioning took 4 minutes to reach its desired temperature of 22℃ whereas the standard air conditioning system (Refrigeration Cycle) took 20 minutes to cool to a room temperature. Economically it was also discovered that thermoelectric air conditioning system is 50% cheaper than the refrigeration cycle air conditioning systems. The thermoelectric air conditioner has cheaper maintenance and greater estimated life span of 7 years more than the refrigeration air conditioner. This is because the air conditioner that operates on the refrigeration cycle uses a rotating compressor while the thermoelectric air conditioner uses thermometric module.


2018 ◽  
Vol 931 ◽  
pp. 920-925
Author(s):  
Zohrab Melikyan ◽  
Naira Egnatosyan ◽  
Siranush Egnatosyan

Centralized air conditioning systems are widely used in buildings at present. In these conditioners, the outside air gets required temperature, humidity, purity, and other features, necessary for creating comfort microclimate in inside areas of houses, and by the help of fans and air ducts the processed air moves to all rooms of a building. As a result, the creation and maintenance of comfort conditions in buildings become complicated and expensive activity. From this point of view, it is becoming more expedient to install local air conditioners in each room instead of single central one for the whole building. For this reason new local air conditioner is developed.


Author(s):  
Jianghong Wu ◽  
Shuangfeng Wang ◽  
Yunting Ge

Two type condensers of R22 residential air conditioning systems were investigated in this study. Two R22 residential air-conditioning systems, one with a microchannel condenser and the other with a round-tube condenser, were examined experimentally, while the other components of the two systems were identical except the condensers. Based on the principle of the microchannel condensation, the analysis of heat transfer along parallel heat exchanger was conducted. The non-uniform air velocity distribution at the face of the microchannel condenser and refrigerant distribution in headers were taken into account in this research. The mechanism and possibility of the superior thermal performance as compared with conventional fin-tube heat exchangers were discussed. In addition, the maximum of thermal performance influenced by the running parameter was experimentally measured. The experimental results show that with one third face area of round tube heat exchanger, microchannel condenser’s pressure drop increase around 12–23% and refrigeration output increase 2–5%, refrigerant charge decreases around 50%, it is found to be a promising candidate for residential air conditioning condenser.