scholarly journals Demonstration poloidal coil test facility. The performance test results of the cryogenic cold compressor.

Author(s):  
Masahiko SATO ◽  
Katumi KAWANO ◽  
Eisuke TADA ◽  
Tadao HIYAMA ◽  
Takashi KATO ◽  
...  
Author(s):  
Yun-Je Cho ◽  
Yeon-Sik Kim ◽  
Seok Cho ◽  
Seok Kim ◽  
Byoung-Uhn Bae ◽  
...  

Korea Atomic Energy Research Institute (KAERI) has designed and constructed a test facility for reactor coolant pumps (RCPs). The RCP Test Facility (RCPTF) has the capability to test a RCP under the operation condition of an Advanced Power Reactor 1400 MW (APR1400). The design values of the facility are 17.2 MPa, 343 °C, 11.7 m3/s, and 13 MW in maximum pressure, temperature, flow rate, and electrical power, respectively. In the facility, it is possible to perform a type test for a newly-developed RCP as well as a production test for a RCP before its installation in a nuclear power plant. For the production test, H-Q curves under the cold and hot conditions are acquired. For the type test, various transient tests are additionally performed including four types of seal transient tests, a thrust bearing transient test, a cost down test, and so on. To acquire H-Q curves of a RCP, the flow rate should be controlled by varying the flow resistance in the test loop. The RCPTF uses a Variable Restriction Orifice (VRO) whose flow area can be controlled by moving the two orifice plates installed in-parallel. The need for flow control valves and bypass lines was eliminated using the VRO such that the flow disturbance was minimized. The flow rate in the main loop of the RCPTF is measured by a standard venture flow meter. The flow rate in the RCPTF is very high and thus the venture flow meter could not be calibrated in the entire range of Reynolds number corresponding to the operating condition in the APR1400. The calibration was conducted at the Colorado Experiment Engineering Station Inc. (CEESI) in the USA where natural gas is used for a working fluid. If a discharge coefficient calibrated with the gas is applied in the test results performed using the water as a working fluid, a discrepancy can occur due to the static hole error. Therefore, the static hole error was compensated in the test results and the result shows the improvement. The effect of the temperature on the pressure pulsation amplitude was also evaluated. During a cold performance test and heat-up phase to the condition of a hot performance test, an abnormal increase in the pressure pulsation amplitude was observed near the specific temperature range. This is acoustic resonance phenomena that occur when a blade passing frequency of the RCP is proportional to the harmonic resonance frequency of the RCPTF.


2004 ◽  
Vol 41 (3) ◽  
pp. 385-392 ◽  
Author(s):  
Hirofumi OHASHI ◽  
Yoshitomo INABA ◽  
Tetsuo NISHIHARA ◽  
Yoshiyuki INAGAKI ◽  
Tetsuaki TAKEDA ◽  
...  

Author(s):  
Ihor S. Diakunchak

The fully loaded factory test of the CW251B12 45 MW class industrial gas turbine is described in this paper. This gas turbine is the latest uprating of the W251 series of engines. The main objectives of the factory test were the verification of the performance and the mechanical integrity of the new engine model. A brief description of the main features of the engine, the application of the first unit, the test facility, and the engine instrumentation used in the test is included. Details of the engine performance test results, telemetry test data results, and the hot end component metal temperature measurements are provided.


Author(s):  
Hidemasa YAMAMURA ◽  
Eisuke TADA ◽  
Takashi KATO ◽  
Tadao HIYAMA ◽  
Katsumi KAWANO ◽  
...  

1991 ◽  
Vol 113 (4) ◽  
pp. 482-487 ◽  
Author(s):  
I. S. Diakunchak

The fully loaded factory test of the CW251B12 45 MW class industrial gas turbine is described in this paper. This gas turbine is the latest uprating of the W251 series of engines. The main objectives of the factory test were the verification of the performance and the mechanical integrity of the new engine model. A brief description of the main features of the engine, the application of the first unit, the test facility, and the engine instrumentation used in the test is included. Details of the engine performance test results, telemetry test data results, and the hot end component metal temperature measurements are provided.


Author(s):  
Ihor S. Diakunchak ◽  
David R. Nevin

A fully loaded factory test of the CW251B10 41MW class industrial gas turbine was carried out at the Westinghouse Canada test facility. This gas turbine, which is the latest of the W251 engine series, represents an advancement in industrial gas turbine technology. One of the main objectives of the factory test was the verification of the engine performance. The test results demonstrated that the CW251B10 engine achieved its performance goals. This paper describes some of the results of the performance tests and includes engine component performance details.


2005 ◽  
Vol 127 (1) ◽  
pp. 170-177 ◽  
Author(s):  
R. Bettocchi ◽  
M. Pinelli ◽  
P. R. Spina

A multistage compressor test facility, fully instrumented with a dedicated data acquisition and processing system, has been developed to conduct experimental research work at the University of Ferrara. This paper provides a systematic description of the uncertainty analysis procedures required for compressor testing, including preliminary performance test results, in addition to a brief description of the test facility and its capabilities.


Author(s):  
Hirofumi OHASHI ◽  
Yoshitomo INABA ◽  
Tetsuo NISHIHARA ◽  
Yoshiyuki INAGAKI ◽  
Tetsuaki TAKEDA ◽  
...  

Author(s):  
R. Bettocchi ◽  
M. Pinelli ◽  
P. R. Spina

A multi-stage compressor test-facility, fully instrumented with its dedicated data acquisition and processing system, has been developed to conduct experimental research work at the University of Ferrara. This paper provides a systematic description of the uncertainty analysis procedures required for compressor testing, including preliminary performance test results, in addition to a brief description of the test facility and its capabilities.


Author(s):  
Wirda Linda

This research is motivated by the low desire of students in writing travel reports. The lack of students' knowledge of the report concept, the lack of students' knowledge of the 5W + 1H report points of good and correct language, the lack of students' knowledge of the spatial, time and topic pattern and not yet reached KKM 75. The method used by the teacher has not been interesting, lecture method. The purpose of this study is to describe the skills of writing travel reports by using Round Club learning model which is viewed from the aspect of understanding the report concept, the use of 5W +1H report points, the spatial, time, and topic pattern.The population of this study is the students of class V Lessons Year 2017/2018 which amounted to 2 classes with the number 80. The sample of research as much as two classes taken by the sample of propotional.Class V.1 as experimental class and class V.2 as control class. The research instrument used is performance test. Provide an assessment by specifying the subject of the 5W + 1H report, as well as the spatial, time and topic pattern. Data were analyzed by 't' test by first testing normality, homogeneity, and hypothesis testing.The results showed that the average control class 68 with more than enough qualifications with standard deviation 16.96. 83 experimental class with good qualification and standard deviation of 15.42 and there is a significant influence on the result of writing skill of class V SDN 01 Nagari Bukik SikumpaSubdistrict, Lima Puluh Kota. This is evidenced by the average value of writing skills in the experiment class higher than the average value in the control class. Normality test results indicate that the two sample classes of  Lo  values in the control class -0.2141 are smaller than the normal 0.190 Lt distributed. Homogeneity test results that the variation of this study is homogeneous at a real level of 0.05, because Ftable 2.16 > Fhitung 1.21 and the results of data analysis then obtained = 2.78 > 1.70 t table, so H0 rejected and H1 accepted. It can be concluded that there is Influence. Using  Learning  Model of Student Group Writing  Skills Travel Report of students of class V SDN 01 Nagari Bukik Sikumpa Subdistrict, Kabupaten Lima Puluh Kota.KeyWords: model pembelajaran round club, menulis laporan perjalanan.