scholarly journals Development of Gamma-Ray Compton Imager Using Room-Temperature 3-D Position Sensitive Semiconductor Detectors

2003 ◽  
Author(s):  
Zhong He ◽  
David Whe ◽  
Glenn Knoll
Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7316
Author(s):  
Nicola Sarzi Amadè ◽  
Manuele Bettelli ◽  
Nicola Zambelli ◽  
Silvia Zanettini ◽  
Giacomo Benassi ◽  
...  

The analysis of γ-ray spectra can be an arduous task, especially in the case of room temperature semiconductor detectors, where several distortions and instrumental artifacts conceal the true spectral shape. We developed a genetic algorithm to perform the unfolding of γ-spectra in order to restore the true energy distribution of the incoming radiation. We successfully validated our approach on experimental spectra of four radionuclides (241Am, 57Co, 137Cs and 133Ba) acquired with two CdZnTe-based detectors with different contact geometries (single pixel and drift strip). The unfolded spectra consist of δ-like peaks in correspondence with the radiation emissions of each radioisotope.


2021 ◽  
Vol 12 (5) ◽  
pp. 645-649
Author(s):  
Yu Gu ◽  
Yuqing Qiao ◽  
Yusen Meng ◽  
Ming Yu ◽  
Bowu Zhang ◽  
...  

Herein, we report for the first time the synthesis of polypyrrole copolymers with good solvent-dispersibility under gamma-ray irradiation at room temperature in air.


1997 ◽  
Vol 487 ◽  
Author(s):  
E. Caroli ◽  
G. Bertuccio ◽  
G. De Cesare ◽  
A. Donati ◽  
W. Dusi ◽  
...  

AbstractAn important region of the electromagnetic spectrum for astrophysics is the hard X- and gamma ray band between 10 keV and a few MeV, where several processes occur in a wide variety of objects and with different spatial distribution and time scales. In order to fulfill the observational requirements in this energy range and taking into account the opportunities given by small/medium size missions (e.g. on the ISS), we have proposed a compact, wide field camera based on a thick (1 cm) position sensitive CdTe detector (PSD). The detector is made of an array of 128×96 CdTe microspectrometers with a pixel size of 2×2 mm2. The basic element of the PSD is the linear module that is an independent detection unit with 32 CdTe crystals and monolithic front-electronics (ASIC) supported by a thin (300 μm) ceramic layer. The expected performance of the PSD over the operative energy range and some of the required ASIC functionality are presented and discussed.


2019 ◽  
Vol 29 (01n02) ◽  
pp. 53-59
Author(s):  
M. Nogami ◽  
K. Hitomi ◽  
A. Terakawa ◽  
K. Ishii

For the first time, particle-induced X-ray emission (PIXE) spectra were obtained using TlBr detectors. The TlBr detector was fabricated from a crystal grown with material purified by the zone purification. Its active volume was 1.5 mm × 1.5 mm × 3.1 mm, and it exhibited an energy resolution of a 6.2 keV full-width at half-maximum (FWHM) for 59.5 keV at room temperature. The detector was installed into a PIXE system at Aomori Prefecture Quantum Science Center. A Pb plate target in the PIXE chamber was irradiated with a 20 MeV proton beam, and X-ray peaks for Pb K[Formula: see text] and K[Formula: see text] were successfully detected by the TlBr detector at room temperature.


Sign in / Sign up

Export Citation Format

Share Document