scholarly journals Calibration of neutron moisture gauges and their ability to spatially determine soil water content in environmental studies

Author(s):  
J.W. Nyhan ◽  
J.L. Martinez ◽  
G.J. Langhorst
1972 ◽  
Vol 79 (1) ◽  
pp. 75-81 ◽  
Author(s):  
F. A. Langton

SUMMARYPotato varieties were grown in the field in soil uniformly infected with Streptomyces scabies. In 1969 tubers were severely and evenly infected but in 1971 infection was slight and not uniform. Agreement of varietal ranking with agricultural experience was good in 1969 but poor in 1971.In 1971, plots protected from rainfall after planting were dry enough at the start of tubering for severe infection; covering the plots for a further 6 weeks followed by irrigation to field capacity resulted in good yields of evenly and severely scabbed tubers. Irrigation during this period suppressed scabbing. The results were easily interpreted in relation to fluctuations in soil-water content measured by a neutron moisture-meter.The efficiency of using only one site and the need to reduce variability in scab screening tests are discussed.


1993 ◽  
Vol 33 (1) ◽  
pp. 59 ◽  
Author(s):  
GJ O'Leary ◽  
M Incerti

A study was undertaken to compare 3 neutron moisture meters (NMMs) over a range of counting times on 2 soil types in north-westem Victoria. The meters were a Pitman Wallingford 225 (WAL225), a Campbell Pacific Nuclear 503 (CPN503), and a Campbell Pacific Nuclear 501DR (CPN501). The soil types were a grey self-mulching clay and a solonised brown soil (sandy loam). The 3 NMMs exhibited different count rates in water, from 242 to 2645 counts per second. It was necessary to increase the counting time of CPN501 to 64 s to achieve a comparable performance to WAL225 at 16 s. Over the 15-month experiment, standard counts remained relatively constant for WAL225 and CPN501, but CPN503 showed pronounced variation. In field calibrations, the inclusion of depth (as a separate variable to account for neutron absorbing gradients in the soil profile) made significant improvement to the regression of all NMMs irrespective of counting time. No improvements in the calibration were achieved using density corrections from core samples for individual layers. On both soil types, WAL225 and CPN503 performed similarly to each other, with very similar residual mean squares and coefficients of determination. On the grey clay, WAL225 and CPN503 explained 77 and 88% of the variation in soil water content, respectively. CPN501 performed poorly, even with a 64 s counting time, and explained only 52% of the variation when depth was included. When depth was excluded this fell to 25%. On the sandy loam, WAL225 and CPN503 explained 76 and 74%, respectively, of the variation in soil water content. CPN501 again performed poorly with a 64 s counting time, accounting for 65% of the variation when depth was included and 33% with depth excluded. Examples of poor calibrations or none at all in water use studies are discussed and typical errors are demonstrated.


Soil Research ◽  
1986 ◽  
Vol 24 (1) ◽  
pp. 11 ◽  
Author(s):  
DJ Wilson ◽  
AIM Ritchie

A multigroup diffusion theory calculation based on a nuclear reactor neutronics code is used to determine the response of a neutron moisture meter to changes in soil parameters such as dry soil density, soil water content, thermal neutron absorption cross-section and neutron scattering crosssection. Empirical equations which fit the results can be used to estimate the response at values of the soil parameters other than those used in the calculations. These equations can also be used to estimate the accuracy with which the parameters must be known to achieve a required accuracy in the derived soil water content.


2020 ◽  
Vol 36 (1) ◽  
pp. 39-54
Author(s):  
Gary W. Marek ◽  
Thomas H. Marek ◽  
Kevin R. Heflin ◽  
Dana O. Porter ◽  
Jerry E. Moorhead ◽  
...  

Abstract. The use of soil water sensors is commonly advocated to aid and improve irrigation management in crop production systems. However, there are concerns about how sensor type, installation technique, sensor orientation, and soil texture may affect sensor accuracy. A field study was conducted to compare the performance of three commercially available soil water sensors (Acclima 315L, Decagon GS1, and Campbell Scientific 655) and a soil water potential sensor (Watermark 200SS) using different installation orientations of horizontal insertion, laid horizontal placement, and vertical insertion at depths of 15, 46, and 76 cm (6, 18, and 30 in.) in an irrigated clay loam soil field. Results indicated all sensors demonstrated similar trends of soil water content in response to wetting events (precipitation and irrigation) at the 15 cm depth following a 4-month settling period prior from the start of the growing season. Comparatively, the Acclima 315L performed well using horizontal insertion compared to calibrated neutron moisture meters (NMMs) at depths of 46 and 76 cm with R2 of 0.73 and 0.96 and slopes of 1.36 and 1.47, respectively. In addition, water storage in the 0.9 m soil profile integrated using the horizontally inserted Acclima 315L across the three depths matched closely with profile water storage determined by the NMMs with a mean difference (MD) and root mean square error (RMSE) of 25.7 and 36.4 mm. However, site-specific corrections or calibrations for each sensor type are required for accurate soil water content estimations with this clay loam soil for irrigation management applications. Keywords: Corn, Irrigation management, Neutron moisture meter, Soil water content, Soil water sensors, Semi-arid region.


1992 ◽  
Vol 49 (spe) ◽  
pp. 111-121 ◽  
Author(s):  
C. Kirda ◽  
K. Reichardt

The neutron moisture gauge is compared with the gravimetric-core soil sampling technique, tensiometers and resistance blocks in relation to stability, Held variability, spatial dependence and number of samples needed at a given level of significance. The variance of field water content measurements with neutron moisture gauges is lower than that of the gravimetric sampling, which therefore requires 2 to 6 times as many samples as the number of measuring sites of the gauges to attain the same level of significance. The space dependence of the measurements made with the subsurface gauge varied depending on the average field soil water content. No space dependence was evident when the water content was lower than 0.2 cm³.cm-3 (50% saturation). Measurements with the tensiometers and resistance blocks manifested no spatial dependence and therefore randomly selected measuring sites can be adapted to Held research work where these methods are to be utilized. Soil water content measurements estimated with neutron moisture gauges showed well defined temporal stability (i.e., the lowest, average and the highest soil water content measurements occur at the same field site) which implies that soil water status of an entire field can be assessed with measurements limited to few locations. Measurements with both tensiometers and the resistance blocks are time variant (i.e., the site giving field average water content changes spatially in time) owing to their relatively smaller measuring domains (i.e., scale of the area which can be represented by a single measurement) as compared to neutron gauges. Therefore it is not possible to define the measuring sites of the tensiometers and resistance blocks as to assess soil water status of the entire field, as it could be done with the neutron gauge.


Author(s):  
M.C.H.Mouat Pieter Nes

Reduction in water content of a soil increased the concentration of ammonium and nitrate in solution, but had no effect on the concentration of phosphate. The corresponding reduction in the quantity of phosphate in solution caused an equivalent reduction in the response of ryegrass to applied phosphate. Keywords: soil solution, soil water content, phosphate, ryegrass, nutrition.


2010 ◽  
Vol 59 (1) ◽  
pp. 157-164 ◽  
Author(s):  
E. Tóth ◽  
Cs. Farkas

Soil biological properties and CO2emission were compared in undisturbed grass and regularly disked rows of a peach plantation. Higher nutrient content and biological activity were found in the undisturbed, grass-covered rows. Significantly higher CO2fluxes were measured in this treatment at almost all the measurement times, in all the soil water content ranges, except the one in which the volumetric soil water content was higher than 45%. The obtained results indicated that in addition to the favourable effect of soil tillage on soil aeration, regular soil disturbance reduces soil microbial activity and soil CO2emission.


Author(s):  
Justyna Szerement ◽  
Aleksandra Woszczyk ◽  
Agnieszka Szyplowska ◽  
Marcin Kafarski ◽  
Arkadiusz Lewandowski ◽  
...  