scholarly journals Desalination of brackish groundwater by direct contact membrane distillation

2010 ◽  
Vol 61 (8) ◽  
pp. 2013-2020 ◽  
Author(s):  
D. Y. Hou ◽  
J. Wang ◽  
D. Qu ◽  
Z. K. Luan ◽  
C. W. Zhao ◽  
...  

The direct contact membrane distillation (DCMD) applied for desalination of brackish groundwater with self-made polyvinylidene fluoride (PVDF) membranes was presented in the paper. The PVDF membrane exhibited high rejection of non-volatile inorganic salt solutes and a maximum permeate flux 24.5 kg m−2 h−1 was obtained with feed temperature at 70°C. The DCMD experimental results indicated that the feed concentration had no significant influence on the permeate flux and the rejection of solute. When natural groundwater was used directly as the feed, the precipitation of CaCO3 would be formed and clog the hollow fibre inlets with gradual concentration of the feed, which resulted in a rapid decline of the module efficiency. The negative influence of scaling could be eliminated by acidification of the feed. Finally, a 250 h DCMD continuous desalination experiment of acidified groundwater with the concentration factor at constant 4.0 was carried out. The permeate flux kept stable and the permeate conductivity was less than 7.0 μS cm−1 during this process. Furthermore, there was no deposit observed on the membrane surface. All of these demonstrated that DCMD could be efficiently used for production of high-quality potable water from brackish groundwater with water recovery as high as 75%.

2010 ◽  
Vol 61 (12) ◽  
pp. 3178-3187 ◽  
Author(s):  
D. Y. Hou ◽  
J. Wang ◽  
B. Q. Wang ◽  
Z. K. Luan ◽  
X. C. Sun ◽  
...  

The direct contact membrane distillation (DCMD) applied for fluoride removal from brackish groundwater is presented. The self-prepared polyvinylidene fluoride membrane exhibited high rejection of inorganic salt solutes and a maximum permeate flux 35.6 kgm−2 h−1 was obtained. The feed concentration had no marked impact on the permeate flux and the rejection of fluoride. The precipitation of CaCO3 would clog the hollow fiber inlets and foul the membrane surface with the increase of concentration factor when natural groundwater was used directly as the feed, which resulted in a rapid decline of the module efficiency. This phenomenon was diminished by acidification of the feed. The experimental results showed that the permeate flux and the quality of obtained distillate kept stable before concentration factor reached 5.0 with the acidified groundwater as feed. The membrane module efficiency began to decline gradually when the feed continued to be concentrated, which can be mainly attributed to the formation of CaF2 deposits on the membrane surface. Finally, a 300 h continuous fluoride removal experiment on acidified groundwater was carried out with concentration factor at 4.0, the permeate flux kept stable and the permeate fluoride was not detected.


2018 ◽  
Vol 30 (1) ◽  
pp. 109-120 ◽  
Author(s):  
Dong-Wan Cho ◽  
Gihoon Kwon ◽  
Jeongmin Han ◽  
Hocheol Song

In this study, the influence of humic acid on the treatment of coalbed methane water by direct contact membrane distillation was examined with bench-scale test unit. During short-term distillation (1000 min), high level of humic acid above 50 ppm resulted in significant decrease in permeate flux, while low level of humic acid (∼2 ppm) had little influence on the flux. For the long-term distillation (5000 min), the flux decline began at 3400 min in the presence of 5 ppm humic acid and 5 mM Ca2+, and decreased to ∼40% of initial flux at 5000 min. The spectroscopic analysis of the membrane used revealed that the surface was covered by hydrophilic layers mainly composed of calcite. The membrane fouling effect of humic acid became more significant in the presence of Ca2+ due to more facile calcite formation on the membrane surface. It was demonstrated that humic acid enhanced CaCO3 deposition on the membrane surfaces, thereby expediting the scaling phenomenon.


2014 ◽  
Vol 69 (9) ◽  
Author(s):  
S. O. Lai ◽  
K. C. Chong ◽  
K. M. Lee ◽  
W. J. Lau ◽  
B. S. Ooi

Membrane distillation (MD) is one of the recent rising membrane separation techniques adopted in the desalination and wastewater treatment. Unlike other pressure-driven separation processes such as reverse osmosis and nanofiltration, MD is a thermal-driven process which involves vapor pressure difference across the feed and permeates solutions. As such, MD requires low energy consumption. Hydrophobic polymeric materials such as polyvinylidene fluoride (PVDF) are frequently used in direct contact membrane distillation (DCMD) due to low surface energy and promising thermal resistance. In this study, the DCMD hollow fiber membranes were separately prepared with PVDF and PVDF blended with lithium chloride (LiCl) through dry/wet phase inversion method. Subsequently, the membranes were used in a DCMD process to remove sodium chloride (NaCl) under different feed inlet temperatures to examine the effect of LiCl additives on the neat membrane. The result showed that by adding LiCl into the neat membrane solution, the finger-like structure was change to a sponge-like structure with microvoids. Furthermore, the performance of the LiCl additive membrane in term of permeate flux was found to be 20% higher compared to that of the neat membrane. Other results of the membrane characteristics were also discussed.      


2010 ◽  
Vol 62 (2) ◽  
pp. 347-352 ◽  
Author(s):  
Ching-Jung Chuang ◽  
Kuo-Lun Tung ◽  
Yang-Hsiang Fan ◽  
Chii-Dong Ho ◽  
James Huang

This paper reports experiments using a flat-sheet module with 0.18 ∼ 0.45 μm ePTFE (expanded polytetrafluoroethylene) and PVDF (polyvinylidene fluoride) membranes to show the effects of membrane properties, salt concentration and fluid hydrodynamics on the permeate flux and salt rejection of DCMD (direct contact membrane distillation). A theoretical prediction of the permeate flux was carried out, and was in close agreement with the experimental results. In addition, the energy integration of the process was also analyzed in order to evaluate module design to increase energy efficiency. According to the simulated results of the energy integration design, a combination of simultaneous cooling of the permeate stream and an additional heat exchanger to lower the temperature of the permeate stream not only enhances the MD flux, but also reduces energy consumption.


Membranes ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 493
Author(s):  
Amine Charfi ◽  
Fida Tibi ◽  
Jeonghwan Kim ◽  
Jin Hur ◽  
Jinwoo Cho

This study aims to investigate the effect of operational conditions on organic fouling occurring in a direct contact membrane distillation (DCMD) system used to treat wastewater. A mixed solution of sodium alginate (SA) and bovine serum albumin (BSA) was used as a feed solution to simulate polysaccharides and proteins, respectively, assumed as the main organic foulants. The permeate flux was observed at two feed temperatures 35 and 50 °C, as well as three feed solution pH 4, 6, and 8. Higher permeate flux was observed for higher feed temperature, which allows higher vapor pressure. At higher pH, a smaller particle size was detected with lower permeate flux. A mathematical model based on mass balance was developed to simulate permeate flux with time by assuming (i) the cake formation controlled by attachment and detachment of foulant materials and (ii) the increase in specific cake resistance, the function of the cake porosity, as the main mechanisms controlling membrane fouling to investigate the fouling mechanism responsible of permeate flux decline. The model fitted well with the experimental data with R2 superior to 0.9. High specific cake resistance fostered by small particle size would be responsible for the low permeate flux observed at pH 8.


2019 ◽  
Vol 25 (11) ◽  
pp. 47-54
Author(s):  
Ahmed Shamil Khalaf ◽  
Asrar Abdullah Hassan

Membrane distillation (MD) is a hopeful desalination technique for brine (salty) water. In this research, Direct Contact Membrane Distillation (DCMD) and  Air Gap Membrane Distillation (AGMD) will be used. The sample used is from Shat Al –Arab water (TDS=2430 mg/l). A polyvinylidene fluoride (PVDF) flat sheet membrane was used as a flat sheet form with a plate and frame cell. Several parameters were studied, such as; operation time, feed temperature, permeate temperature, feed flow rate. The results showed that with time, the flux decreases because of the accumulated fouling and scaling on the membrane surface. Feed temperature and feed flow rate had a positive effect on the permeate flux, while permeate temperature had a reverse effect on permeate flux. It is noticeable that the flux in DCMD is greater than AGMD, at the same conditions. The flux in DCMD is 10.95LMH, and that in AGMD is 7.14 LMH.  In AGMD, the air gap layer made a high resistance. Here the temperature transport reduces in the permeate side of AGMD due to the air gap resistance. The heat needed for AGMD is lower than DCMD, this leads to low permeate flux because the temperature difference between the two sides is very small, so the driving force (vapor pressure) is low.                                                                                               


Sign in / Sign up

Export Citation Format

Share Document