Water reuse for urban landscape irrigation: aspersion and health related regulations

2008 ◽  
Vol 57 (5) ◽  
pp. 781-787 ◽  
Author(s):  
F. Brissaud ◽  
E. Blin ◽  
S. Hemous ◽  
L. Garrelly

The Mediterranean seaside resort of Le Grau du Roi includes 40 hectares of landscaped areas spray irrigated with river water supplied through a separate network. Wastewater collected from several municipalities is treated in an activated sludge wastewater treatment plant (WWTP) and polished in waste stabilization ponds (WSPs). Planned substitution of treated wastewater for river water is hindered by spray irrigation prohibition within a 100 m distance from houses and recreational areas. WWTP and WSP effluents were monitored for pathogens with a particular attention to Legionella in Spring and Summer 2006. Helminth eggs, salmonellae and enteroviruses were never detected neither in WWTP effluent nor in the ponds. Legionella spp content was slightly higher or of the order of magnitude of river water contents. Regarding Legionella pneumophila contents, WSP effluent did not significantly differ from the river water. E.coli and enterococci contents in WSP effluents complied with the “excellent quality” criteria of the European Directive for coastal bathing waters. Therefore, substituting WSP effluents to river water is unlikely to alter health risks related to spray irrigation and, in this case, the buffer zone required by the French water reuse guidelines appears being short of support.

2001 ◽  
Vol 43 (2) ◽  
pp. 91-99 ◽  
Author(s):  
T. Iwane ◽  
T. Urase ◽  
K. Yamamoto

Escherichia coli and coliform group bacteria resistant to seven antibiotics were investigated in the Tama River, a typical urbanized river in Tokyo, Japan, and at a wastewater treatment plant located on the river. The percentages of antibiotic resistance in the wastewater effluent were, in most cases, higher than the percentages in the river water, which were observed increasing downstream. Since the possible increase in the percentages in the river was associated with treated wastewater discharges, it was concluded that the river, which is contaminated by treated wastewater with many kinds of pollutants, is also contaminated with antibiotic resistant coliform group bacteria and E.coli. The percentages of resistant bacteria in the wastewater treatment plant were mostly observed decreasing during the treatment process. It was also demonstrated that the percentages of resistance in raw sewage are significantly higher than those in the river water and that the wastewater treatment process investigated in this study works against most of resistant bacteria in sewage.


Water ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 2764
Author(s):  
Argyro Plevri ◽  
Klio Monokrousou ◽  
Christos Makropoulos ◽  
Christos Lioumis ◽  
Nikolaos Tazes ◽  
...  

Water reuse and recycling is gaining momentum as a way to improve the circularity of cities, while recognizing the central role of water within a circular economy (CE) context. However, such interventions often depend on the location of wastewater treatment plants and the treatment technologies installed in their premises, while relying on an expensive piped network to ensure that treated wastewater gets transported from the treatment plant to the point of demand. Thus, the penetration level of treated wastewater as a source of non-potable supply in dense urban environments is limited. This paper focuses on the demonstration of a sewer mining (SM) unit as a source of treated wastewater, as part of a larger and more holistic configuration that examines all three ‘streams’ associated with water in CE: water, energy and materials. The application area is the Athens Plant Nursery, in the (water stressed) city of Athens, Greece. SM technology is in fact a mobile wastewater treatment unit in containers able to extract wastewater from local sewers, treat it directly and reuse at the point of demand even in urban environments with limited space. The unit consists of a membrane bioreactor unit (MBR) and a UV disinfection unit and produces high quality reclaimed water for irrigation and also for aquifer recharge during the winter. Furthermore, a short overview of the integrated nutrient and energy recovery subsystem is presented in order to conceptualise the holistic approach and circularity of the whole configuration. The SM technology demonstrates flexibility, scalability and replicability, which are important characteristics for innovation uptake within the emerging CE context and market.


Water ◽  
2020 ◽  
Vol 12 (4) ◽  
pp. 1085 ◽  
Author(s):  
Fan Liu ◽  
Nadia Nord ◽  
Kai Bester ◽  
Jes Vollertsen

Microplastic (MP) pollution is a global environmental issue, and traditionally treated wastewater has been identified as a source of land-based microplastics into the aquatic environment. This study evaluated the performance of a pilot-scale biofilter to polish wastewater treatment plant (WWTP) effluent before it enters the environment. The filter was divided into four zones, allowing the concentration of microplastics to be followed through the filter. It was fed with secondary effluent from a conventional WWTP in Denmark. The raw effluent from the WWTP contained 917 items m−3 which corresponded to a mass concentration of 24.8 µg m−3. After the top layer of the biofilter, the concentration had decreased to a median value of 197 item m−3 and 2.8 µg m−3, indicating an overall removal efficiency of 79% in terms of particle number and 89% in terms of particle mass. We also observed a tendency that MP of larger size and higher particle mass were more likely to be retained. After the last filtration zone, all MP larger than 100 µm had been removed. The results of this study demonstrate that biofilters are able to lower the MP abundance in treated wastewater significantly, but a complete removal is not ensured, hence some MP, particularly small-sized ones, can still be discharged into the receiving environment.


Water ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 191
Author(s):  
Gozen Elkiran ◽  
Fidan Aslanova ◽  
Salim Hiziroglu

Northern Cyprus (NC) is suffering from limited water resources and reiterated drought condition experiences due to global warming effects. Previous studies revealed that the water management policy in the country is not sustainable from the perspective of demand and balance. Apparently, the reuse of recycled water will be an alternative resource and can be utilized for some specific purposes to reduce water extraction from the ground. It is expected that treated wastewater will reach 20 million cubic meters (MCM) per year after the completion of the new sewage system for Lefkosa. Today, 20,000 m3 of wastewater is treated at the Lefkosa Central Treatment Plant up to the secondary treatment level, in which the degree of treatment varies from 60% to 95% owing to the weather conditions in the country during the year. Effluent water reuse in NC was not accepted due to cultural belief. However, water scarcity was experienced in the country during the last decade, forcing the farmers to benefit from the recycled water. There is no regulatory framework available in the country for effluent water reuse. However, preparation studies are almost finalized after discussions among government and European Union (EU) agencies. Cyprus, as an EU country, has an obligation to treat the wastewater up to the secondary level before releasing it in an environmentally friendly nature, following the Directive 91/271/EEC. This paper analyzes the effluent water reuse possibilities as a component of integrated water resource management in Northern Cyprus considering laboratory experiment results. It appears that applying tertiary treatment in Northern Cyprus will allow 20 MCM of water contribution to the water budget and it will help protect the vulnerable environment. Also, since the cost of tertiary treatment will be 0.2 United States dollars (USD)/m3, it would be reasonable to prefer this process to the desalination of water, which costs of 1 USD/m3.


2014 ◽  
Vol 507 ◽  
pp. 688-692 ◽  
Author(s):  
Hui Cong Pang ◽  
Can Can Zhang ◽  
Tai Zhong Gao

The paper introduced the design parameters of a reclaimed water island engineering in a power plant. The total processing scale was 3.84×104m3/d. The raw water source of this project was the further treated wastewater from municipal treatment plant. The combination of BAF-Lime Conglomeration and Clarification-Filtration was employed in the design for advanced treatment. The operation results showed that the quality of treated water with this process in the reclaimed water island could satisfy the design requirement and the treated water was reused as recirculating cooling water in a thermal power plant.


Author(s):  
Eiji Haramoto ◽  
Bikash Malla ◽  
Ocean Thakali ◽  
Masaaki Kitajima

ABSTRACTWastewater-based epidemiology is a powerful tool to understand the actual incidence of coronavirus disease 2019 (COVID-19) in a community because severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the etiological agent of COVID-19, can be shed in the feces of infected individuals regardless of their symptoms. The present study aimed to assess the presence of SARS-CoV-2 RNA in wastewater and river water in Yamanashi Prefecture, Japan, using four quantitative and two nested PCR assays. Influent and secondary-treated (before chlorination) wastewater samples and river water samples were collected five times from a wastewater treatment plant and three times from a river, respectively, between March 17 and May 7, 2020. The wastewater and river water samples (200–5,000 mL) were processed by using two different methods: the electronegative membrane-vortex (EMV) method and the membrane adsorption-direct RNA extraction method. Based on the observed concentrations of indigenous pepper mild mottle virus RNA, the EMV method was found superior to the membrane adsorption-direct RNA extraction method. SARS-CoV-2 RNA was successfully detected in one of five secondary-treated wastewater samples with a concentration of 2.4 × 103 copies/L by N_Sarbeco qPCR assay following the EMV method, whereas all the influent samples were tested negative for SARS-CoV-2 RNA. This result could be attributed to higher limit of detection for influent (4.0 × 103–8.2 × 104 copies/L) with a lower filtration volume (200 mL) compared to that for secondary-treated wastewater (1.4 × 102–2.5 × 103 copies/L) with a higher filtration volume of 5,000 mL. None of the river water samples tested positive for SARS-CoV-2 RNA. Comparison with the reported COVID-19 cases in Yamanashi Prefecture showed that SARS-CoV-2 RNA was detected in the secondary-treated wastewater sample when the cases peaked in the community. This is the first study reporting the detection of SARS-CoV-2 RNA in wastewater in Japan.


2021 ◽  
Vol 12 ◽  
Author(s):  
Harvey N. Summerlin ◽  
Cícero C. Pola ◽  
Eric S. McLamore ◽  
Terry Gentry ◽  
Raghupathy Karthikeyan ◽  
...  

High demand for food and water encourages the exploration of new water reuse programs, including treated municipal wastewater usage. However, these sources could contain high contaminant levels posing risks to public health. The objective of this study was to grow and irrigate a leafy green (romaine lettuce) with treated wastewater from a municipal wastewater treatment plant to track Escherichia coli and antibiotic-resistant microorganisms through cultivation and post-harvest storage to assess their fate and prevalence. Contamination levels found in the foliage, leachate, and soil were directly (p < 0.05) related to E. coli concentrations in the irrigation water. Wastewater concentrations from 177 to 423 CFU ml−1 resulted in 15–25% retention in the foliage. Leachate and soil presented means of 231 and 116% retention, respectively. E. coli accumulation on the foliage was observed (p < 0.05) and increased by over 400% during 14-day storage (4°C). From randomly selected E. coli colonies, in all four biomass types, 81 and 34% showed resistance to ampicillin and cephalothin, respectively. Reclaimed wastewater usage for leafy greens cultivation could pose potential health risks, especially considering the bacteria found have a high probability of being antibiotic resistance. Successful reuse of wastewater in agriculture will depend on appropriate mitigation and management strategies to guarantee an inexpensive, efficient, and safe water supply.


2014 ◽  
Vol 4 (4) ◽  
pp. 263-275 ◽  
Author(s):  
Shuang Liu ◽  
Kenneth M. Persson

The potential microbial risk from using treated wastewater is a burning issue to be studied. In Sweden, only a small part of treated wastewater is reused directly, although water reuse could be beneficial. Disinfection is virtually never practised and no protective guidelines for water reuse are found in Sweden. Based on a 1 year monitoring programme of water quality, this paper estimates the microbial risk of Escherichia coli and rotavirus in treated wastewater for different applications of irrigation, landscape, industry, unban non-potable water. A Quantitative Microbial Risk Assessment model is used and the samples were collected from the pond system of Källby wastewater treatment plant in Lund, Sweden. The results are used to evaluate if the treated wastewater after tertiary treatment process combined with pond system can be reused for different applications from a microbial point of view. The risk assessment results show that the studied water is only suitable for agriculture irrigation, while additional treatment or disinfection are needed for other applications since the potential risks are higher than the value that can be accepted. The protective guidelines are discussed based on the process and results of risk assessment and suggestions for establishing a structure of guidelines in Sweden are presented.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Jihyun Kwak ◽  
Bumju Khang ◽  
Eunhee Kim ◽  
Hyunook Kim

Determination of 5-d biochemical oxygen demand (BOD5) is the most commonly practiced test to assess the water quality of surface waters and the waste loading. However, BOD5is not a good parameter for the control of water or wastewater treatment processes because of its long test period. It is very difficult to produce consistent and reliable BOD5results without using careful laboratory quality control practices. This study was performed to develop software sensors to predict the BOD5of river water and wastewater. The software sensors were based on the multiple regression analysis using the dissolved organic carbon (DOC) concentration, UV light absorbance at 254 nm, and synchronous fluorescence spectra. River water samples and wastewater treatment plant (WWTP) effluents were collected at 1-hour interval to evaluate the feasibility of the software sensors. In short, the software sensors developed in this study could well predict the BOD5of river water (r=0.78) and for the WWTP effluent (r=0.90).


1991 ◽  
Vol 23 (10-12) ◽  
pp. 2171-2180 ◽  
Author(s):  
William C. Lauer

Denver's Potable Water Reuse Demonstration Project is designed to examine the feasibility of converting secondary treated wastewater to potable water quality. A 1.0 mgd (44L/s) treatment plant began operation in 1985 and during the first three years many processes were evaluated. Data from the evaluation period was used to select the optimum treatment sequence which is now being used to produce samples for the two-year animal feeding health effects study now underway. Operation in this configuration will continue until early 1991 during which time comprehensive analytical studies will further define the water quality in relation to existing standards and Denver's current potable supply. A decision concerning the full-scale implementation of direct potable reuse will follow extensive analysis of the test results and in-depth economic evaluation.


Sign in / Sign up

Export Citation Format

Share Document