Feedforward aeration control of a Biocos wastewater treatment plant

2001 ◽  
Vol 43 (3) ◽  
pp. 85-91 ◽  
Author(s):  
B. Wett ◽  
K. Ingerie

The Biocos strategy as a cyclical time controlled activated sludge system shows a great variability in operation and control. One topic such a type of treatment plant has to deal with is the optimum relation between aerobic and anoxic conditions. The aeration control has to adapt the length of the nitrification phases to the current constraints in order to save operational costs and maximise nitrogen elimination. Since wastewater treatment plants up to a certain size are usually not equipped with on-line nitrogen probes, influent flow and temperature can be taken as control parameters for the aeration system. The defined relation between influent flow and ammonia load is based on measurements and the relation between ammonia load and required aeration time is model based.

2018 ◽  
Vol 210 ◽  
pp. 02002
Author(s):  
Ioan Nascu

This paper investigates the performance of a new predictive control approach used to improve the energy efficiency and effluent quality of a conventional Wastewater Treatment Plant (WWTP). A two-layer hierarchical control structure is proposed: process control as a lower layer and a higher layer of optimization. The Activated Sludge Process (ASP) optimization using the proposed approach provides an improved aeration system efficiency to reduce energy costs while maintaining the quality parameters of the effluent. The control strategy is evaluated by performing simulations and analyzing the results. The regulatory performances have been tested and the effects of several tuning parameters are investigated.


2009 ◽  
Vol 60 (9) ◽  
pp. 2439-2445 ◽  
Author(s):  
A. Lynggaard-Jensen ◽  
P. Andreasen ◽  
F. Husum ◽  
M. Nygaard ◽  
J. Kaltoft ◽  
...  

Most wastewater treatment plants have several secondary clarifiers or even more sets of clarifiers including several secondary clarifiers, and in practice it is a well known problem that equal distribution of the load to the single clarifier (or set of clarifiers) is very difficult—not to say impossible—to obtain. If the problem is neglected, quite a big percentage of the total clarifier capacity—measured as the max. allowed hydraulic load—can be lost. Further, return sludge rates are seldom controlled by any other means than as a (typically too high) percentage of the inlet to the wastewater treatment plant—giving a varying and too low suspended solids concentration in the return sludge, which again can lead to an unnecessary use of polymer in the pre-dewatering of the surplus sludge taken from the return sludge. A control of the return sludge rate divided into two parts - control of the total return sludge flow and control of how the total flow shall be distributed between the secondary clarifiers - is able to solve the mentioned problems. Finally, as shall be demonstrated on full scale wastewater treatment plants, a considerable increase of the hydraulic capacity of the treatment plants can be obtained.


2014 ◽  
Vol 70 (10) ◽  
pp. 1594-1601 ◽  
Author(s):  
Shijian Ge ◽  
Yunpeng Zhu ◽  
Shuang Qiu ◽  
Xiong Yang ◽  
Bin Ma ◽  
...  

This study evaluated the performance of a full-scale upgrade of an existing wastewater treatment plant (WWTP) with the intermittent cyclic extended aeration system (ICEAS), located in Qingdao, China. The ICEAS system was not able to meet effluent standards; therefore, a series of modifications and control strategies were applied as follows: (1) floating plastic carriers were added to the tank to aid biofilm formation; (2) operation parameters such as mixing and aeration time, feeding rate, and settling time were adjusted and controlled with a real-time control system; (3) a sludge return system and submersible water impellers were added; (4) the aeration system was also improved to circulate carriers and prevent clogging. The modified ICEAS system exhibited efficient organic and nutrient removal, with high removal efficiencies of chemical oxygen demand (89.57 ± 4.10%), NH4+-N (95.46 ± 3.80%), and total phosphorus (91.90 ± 4.36%). Moreover, an annual power reduction of 1.04 × 107 kW·h was realized as a result of these modifications.


1992 ◽  
Vol 26 (5-6) ◽  
pp. 1315-1323 ◽  
Author(s):  
H. Aspegren ◽  
B. Andersson ◽  
U. Nyberg ◽  
J. la C. Jansen

Optimization of wastewater treatment plants with extensive phosphorus and nitrogen removal is complicated. The Klagshamn wastewater treatment plant in Sweden is operated with pre-precipitation of phosphorus with ferric chloride and denitrification with methanol as carbon source. An activated sludge process, operated with pre-precipitation and denitrification with external carbon source in a compartmentalized plant, requires only small tank volumes but increases the need for proper operation and optimization. On-line nitrogen, ammonia, and TOC sensors are used for a day-to-day control and optimization while mathematical modelling is used for long term strategic planning. The on-line measurements are further used as the basis for the modelling. TOC and ammonia sensors at the influent clearly identify typical and extreme loading variations and nitrate measurements in the activated sludge tanks and the effluent shows the dynamics of the processes. These measurements provide a basis for model calibration. In combination low residuals of nitrogen, phosphorus and organic matter can be achieved.


2005 ◽  
Vol 52 (1-2) ◽  
pp. 457-464 ◽  
Author(s):  
O. Bernard ◽  
B. Chachuat ◽  
A. Hélias ◽  
B. Le Dantec ◽  
B. Sialve ◽  
...  

The TELEMAC project brings new methodologies from the Information and Science Technologies field to the world of water treatment. TELEMAC offers an advanced remote management system which adapts to most of the anaerobic wastewater treatment plants that do not benefit from a local expert in wastewater treatment. The TELEMAC system takes advantage of new sensors to better monitor the process dynamics and to run automatic controllers that stabilise the treatment plant, meet the depollution requirements and provide a biogas quality suitable for cogeneration. If the automatic system detects a failure which cannot be solved automatically or locally by a technician, then an expert from the TELEMAC Control Centre is contacted via the internet and manages the problem.


2014 ◽  
Vol 69 (7) ◽  
pp. 1359-1372 ◽  
Author(s):  
Oskar Modin ◽  
David J. I. Gustavsson

Microbial bioelectrochemical systems (BESs) utilize living microorganisms to drive oxidation and reduction reactions at solid electrodes. BESs could potentially be used at municipal wastewater treatment plants (WWTPs) to recover the energy content of organic matter, to produce chemicals useful at the site, or to monitor and control biological treatment processes. In this paper, we review bioelectrochemical technologies that could be applied for municipal wastewater treatment. Sjölunda WWTP in Malmö, Sweden, is used as an example to illustrate how the different technologies potentially could be integrated into an existing treatment plant and the impact they could have on the plant's utilization of energy and chemicals.


2010 ◽  
Vol 2 (5) ◽  
pp. 97-102
Author(s):  
Ala Sokolova ◽  
Mindaugas Rimeika

The paper analyzes the impact of the way of mounting a tube diffuser, the design of an aeration tank and the presence of a fixed carrier on the operational parameters of aeration systems used in small wastewater treatment plants. It was found out that the vertically mounted tube diffuser decreased standard oxygen transfer rate (SOTR) of the aeration system by approximately 20% and standard oxygen transfer efficiency (SOTE) by 25% comparing to the horizontally mounted tube diffuser. It was also defined that the design of the aeration tank might have an impact on the operation parameters of the aeration system: when the centre shell used to protect a diffuser was dismantled from a test tank, SOTR and SOTE increased by approximately 20%. It was also established that the presence of the fixed carrier in the aeration tank did not have an impact on the performance of aeration systems. Finally, research was carried out to compare the operational parameters of two diffusers of different types offered on the market and used in small wastewater treatment plants. It was found out that the performance different type diffusers might vary considerably.


1987 ◽  
Vol 19 (3-4) ◽  
pp. 669-680 ◽  
Author(s):  
Gordon W. Speirs ◽  
Robert D. Hill

As part of a full-scale project to demonstrate the advantages of using automated process control in wastewater treatment plants, on-line sensors used in various control loops were calibrated and/or verified during control system commissioning and startup. The on-line measurements included liquid flow rates, air flow rates, suspended solids concentrations, and dissolved oxygen concentrations. The methods used to confirm instrument performance are presented along with results that show that several instruments were found to operate outside the manufacturers' written specifications. In addition, on-line methods which can help determine when recalibrations are required, and thereby help to reduce maintenance costs and ensure reliability, are also presented.


2003 ◽  
Vol 47 (2) ◽  
pp. 1-34 ◽  
Author(s):  
P.A. Vanrolleghem ◽  
D.S. Lee

A (non-exhaustive) survey of new and existing technologies for the monitoring of wastewater treatment plants is presented. Emphasis is given to the way these sensors can provide insight in the ongoing (bio-) processes. Three different uses for sensors can be found: for monitoring (operator support), in automatic control systems and as tools for plant auditing/optimization/modelling by consultants. From this, sensors have been classified in two basic types: (i) reliable, simple and low maintenance sensors for day-to-day monitoring and control and (ii) advanced, higher maintenance sensors that are used in auditing, model calibration and optimisation. The paper is organized according to the typical unit processes of biological wastewater treatment systems: anaerobic digestion, activated sludge, nutrient removal and sedimentation. Attention is drawn to a number of practical problems associated with the use of sophisticated sensors in the harsh (dirty) conditions of wastewater treatment processes. The use of autocalibration and built-in sensor checks, cleaning systems and reliable sample preparation units is illustrated. The paper ends with a discussion of the applicability of the different sensors.