scholarly journals THE INFLUENCE OF AERATOR MOUNTING AND WASTEWATER TREATMENT PLANT DESIGN ON THE PERFORMANCE OF AERATION SYSTEMS

2010 ◽  
Vol 2 (5) ◽  
pp. 97-102
Author(s):  
Ala Sokolova ◽  
Mindaugas Rimeika

The paper analyzes the impact of the way of mounting a tube diffuser, the design of an aeration tank and the presence of a fixed carrier on the operational parameters of aeration systems used in small wastewater treatment plants. It was found out that the vertically mounted tube diffuser decreased standard oxygen transfer rate (SOTR) of the aeration system by approximately 20% and standard oxygen transfer efficiency (SOTE) by 25% comparing to the horizontally mounted tube diffuser. It was also defined that the design of the aeration tank might have an impact on the operation parameters of the aeration system: when the centre shell used to protect a diffuser was dismantled from a test tank, SOTR and SOTE increased by approximately 20%. It was also established that the presence of the fixed carrier in the aeration tank did not have an impact on the performance of aeration systems. Finally, research was carried out to compare the operational parameters of two diffusers of different types offered on the market and used in small wastewater treatment plants. It was found out that the performance different type diffusers might vary considerably.

2021 ◽  
pp. 1-16
Author(s):  
Abdel Rahman Salem ◽  
Alaa Hasan ◽  
Ahmad Abdelhadi ◽  
Saif Al Hamad ◽  
Mohammad Qandil ◽  
...  

Abstract This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current's kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15”), 53.4 cm (21”), and 68.6 cm (27”) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the Standard Oxygen Transfer Efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65% - 80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.


2018 ◽  
Vol 210 ◽  
pp. 02002
Author(s):  
Ioan Nascu

This paper investigates the performance of a new predictive control approach used to improve the energy efficiency and effluent quality of a conventional Wastewater Treatment Plant (WWTP). A two-layer hierarchical control structure is proposed: process control as a lower layer and a higher layer of optimization. The Activated Sludge Process (ASP) optimization using the proposed approach provides an improved aeration system efficiency to reduce energy costs while maintaining the quality parameters of the effluent. The control strategy is evaluated by performing simulations and analyzing the results. The regulatory performances have been tested and the effects of several tuning parameters are investigated.


2015 ◽  
Vol 809-810 ◽  
pp. 1573-1578
Author(s):  
Casen Panaitescu ◽  
Monica Emanuela Stoica ◽  
Ciner Fehiman

Manufacture of wastewater treatment technologies is an important issue due to the complexity of design parameters and performance. Biological wastewater treatment is a process in which the intensity of oxygen transfer into water is an issue that has been extensively studied but yet insufficiently resolved. The present paper aims to describe an aeration system developed by the author in the laboratory by means of non-conventional technologies, and subsequently implemented in refinery wastewater treatment plants. The aeration system takes the form of modules, which are equipped with a new type of membrane. The analysis of the system performance revealed that oxygen transfer was 62%, specific adsorption of oxygen was 37 % and the specific oxygen transfer was 7%/m. The advantages of this new system are as follows: compared to existing technologies there is a higher rate of oxygen transfer into water; longer life; there are no dead zones in the basin as a result of their location; possibility of operating on separate sections.


2020 ◽  
Vol 13 ◽  
pp. 117862212093585 ◽  
Author(s):  
Karim M Morsy ◽  
Mohamed K Mostafa ◽  
Khaled Z Abdalla ◽  
Mona M Galal

Although significant progress has been achieved in the field of environmental impact assessment in many engineering disciplines, the impact of wastewater treatment plants has not yet been well integrated. In light of this remarkable scientific progress, the outputs of the plants as treated water and clean sludge have become potential sources of irrigation and energy, not a waste. The aim of this study is to assess the environmental impacts of upgrading the wastewater treatment plants from primary to secondary treatment. The Lifecycle Assessment Framework (ISO 14040 and 14044) was applied using GaBi Software. Abu Rawash wastewater treatment plant (WWTP) has been taken as a case study. Two scenarios were studied, Scenario 1 is the current situation of the WWTP using the primary treatment units and Scenario 2 is upgrading the WWTP by adding secondary treatment units. The study highlighted the influence and cumulative impact of upgrading all the primary WWTPs in Egypt to secondary treatment. With the high amount of energy consumed in the aeration process, energy recovery methods were proposed to boost the circular economy concept in Abu Rawash WWTP in order to achieve optimal results from environmental and economic perspectives.


Author(s):  
R. Babko ◽  
V. Pliashechnyk ◽  
T. Kuzmina ◽  
Y. Danko ◽  
J. Szulżyk-Cieplak ◽  
...  

Abstract The work is devoted to the task of simplifying the assessment of the effect of effluents from treatment facilities on the river hydrobiocenosis. The studies were carried out on the mountain river Uzh (Uzhgorod, Ukraine). Our approach to assessing the impact of waste treatment facilities on the river receiver is based on the estimate of the similarity of species composition and quantitative characteristics of populations of organisms from the aerotank and from the river. It is shown that the quantitative development of populations of species of ciliates from the aeration tank is a good indicator for assessing the degradation of organic matter coming with wastewater. The use of qualitative and quantitative characteristics of the protozoa from the wastewater treatment plant as a criterion for assessing the quality of the environment in the area of wastewater discharge showed their representativeness and effectiveness. The use of a limited number of species makes it possible to conduct an express assessment of the effect of effluents on receiving reservoirs for specialists working with activated sludge in the laboratories of treatment facilities.


2005 ◽  
Vol 52 (1-2) ◽  
pp. 39-47 ◽  
Author(s):  
P.F. Greenfield ◽  
D.J. Batstone

The debate as to whether carbon dioxide, methane, nitrous oxide and other greenhouse gas emissions will become subject to increasing regulation, increased restrictions, and probably to some form of carbon tax, has moved from a simple “yes” or “no” to “when”. Wastewater treatment plants will be significantly impacted by increased energy costs and by specific regulations and/or penalties associated with emissions of methane and nitrous oxide. In this paper, the greenhouse gases emissions of different wastewater process options are estimated. The paper outlines the increasing need for wastewater treatment plants to factor greenhouse gas mitigation issues into their medium- as and long-term strategies, and identifies anaerobic enhouse as processes as being at the core of such strategies. Further, the paper identifies a number of key research challenges to be addressed if such strategies are to play a larger role in attenuating the likely impacts of GHG mitigation requirements on wastewater treatment plant design and operation.


FACETS ◽  
2018 ◽  
Vol 3 (1) ◽  
pp. 128-138 ◽  
Author(s):  
Claire N. Freeman ◽  
Lena Scriver ◽  
Kara D. Neudorf ◽  
Lisbeth Truelstrup Hansen ◽  
Rob C. Jamieson ◽  
...  

Wastewater treatment plants (WWTPs) have been identified as hotspots for antimicrobial resistance genes (ARGs) and thus represent a critical point where patterns in ARG abundances can be monitored prior to their release into the environment. The aim of the current study was to measure the impact of the release of the final treated effluent (FE) on the abundance of ARGs in the receiving water of a recently upgraded WWTP in the Canadian prairies. Sample nutrient content (phosphorous and nitrogen species) was measured as a proxy for WWTP functional performance, and quantitative PCR (qPCR) was used to measure the abundance of eight ARGs, the intI1 gene associated with class I integrons, and the 16S rRNA gene. The genes ermB, sul1, intI1, blaCTX-M, qnrS, and tetO all had higher abundances downstream of the WWTP, consistent with the genes with highest abundance in the FE. These findings are consistent with the increasing evidence suggesting that human activity affects the abundances of ARGs in the environment. Although the degree of risk associated with releasing ARGs into the environment is still unclear, understanding the environmental dimension of this threat will help develop informed management policies to reduce the spread of antibiotic resistance and protect public health.


1999 ◽  
Vol 39 (6) ◽  
pp. 89-96
Author(s):  
J. R. Messenger ◽  
J. C. Smith ◽  
M. J. Tetreault ◽  
C. Vitasovic ◽  
S. Zhou ◽  
...  

The use of process and two-dimensional clarifier modelling to investigate the implications of upgrading Melbourne Water's Eastern Treatment Plant to a nitrification/denitrification process is discussed. Results indicate that the existing clarification capacity is sufficient for the increased solids loading arising from operation at a nitrifying sludge age but that the existing diffuser system may need to be replaced in order to achieve the required oxygen transfer rate. The impact of step feeding into unaerated zones to reduce the aeration tank suspended solids concentration and to achieve denitrification is discussed and the installation of baffles to improve the performance of peripheral feed clarifiers is suggested.


Sign in / Sign up

Export Citation Format

Share Document