Optimal rainwater tank design for control of particulate contaminants

2018 ◽  
Vol 19 (2) ◽  
pp. 574-579 ◽  
Author(s):  
Yusik Won ◽  
Mooyoung Han ◽  
Hyunju Park ◽  
Mikyeong Kim

Abstract Rainwater systems, which collect rainfall from the roof surface, are an attractive alternative technology, and one of the cleanest water resources. Microorganisms can be treated by disinfection processes or by inducing a biofilm, but particulate matter can only be easily removed with effective storage tank design parameters. In this study, therefore, the effects of rainwater tank design parameters on the treatment of particulate contaminants are analyzed. The J-type inlet pipe seems to maintain stable rainwater quality by suppressing the resuspension of bottom sediments during rainfall inflow. The intermediate wall can prevent sediment from spreading to the whole storage tank, and provide functions such as securing the stable water quality of the outflow area and managing sediment flow to the inflow region. The baffles can simplify tank management such as sediment drainage and tank cleaning by leading to more sedimentation of particles in the unit area. Based on the water quality monitoring results of pH, biochemical oxygen demand (BOD), suspended solids (SS), and turbidity at the field scale, it is possible to supply a certain quality of water by optimizing tank design parameters alone even if particulate contaminants flow into the rainwater tank.

2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Marco A. García-Morales ◽  
Julio César González Juárez ◽  
Sonia Martínez-Gallegos ◽  
Gabriela Roa-Morales ◽  
Ever Peralta ◽  
...  

The purpose of this study was to evaluate the efficiency of removal of suspended solids in terms of turbidity, color, and chemical oxygen demand (COD) when integrating the electrocoagulation process using aluminum sacrificial anodes and the sand filtration process as a pretreatment of wastewater from the chocolate manufacturing plant in Toluca, México. Wastewater from the chocolate manufacturing industry used in this study is classified as nontoxic, but is characterized as having a high content of color (5952 ± 76 Pt-Co), turbidity (1648 ± 49 FAU), and COD (3608 ± 250 mg/L). Therefore, enhanced performance could be achieved by combining pretreatment techniques to increase the efficiencies of the physical, chemical, and biological treatments. In the integrated process, there was a turbidity reduction of 96.1 ± 0.2% and an increase in dissolved oxygen from 3.8 ± 0.05 mg/L (inlet sand filtration) to 6.05 ± 0.03 mg/L (outlet sand filtration) after 120 min of treatment. These results indicate good water quality necessary for all forms of elemental life. Color and COD removals were 98.2 ± 0.2% and 39.02 ± 2.2%, respectively, during the electrocoagulation process (0.2915 mA/cm2 current density and 120 min of treatment). The proposed integrated process could be an attractive alternative of pretreatment of real wastewater to increase water quality of conventional treatments.


2013 ◽  
Vol 295-298 ◽  
pp. 755-758 ◽  
Author(s):  
Ya Yun Liu ◽  
Zhi Hong Li ◽  
Xiao Jian Liang ◽  
Yan Peng Lin ◽  
Rong Hao Wu ◽  
...  

Based on the water quality investigation data of December in 2010, the water environment quality of Lv-tang River in Zhanjiang national urban wetland park was assessed using single water quality parameter model and integrated water quality index model. The results show that the water quality of Lv-tang River is worse than the national quality standards for Grade V. The water is polluted seriously. The main pollutants are total nitrogen (TN), ammonia nitrogen (NH3-N) and chemical oxygen demand CODCr with their average concentrations of 60.49 mg/L, 30.57 mg/L and 227.38mg/L, respectively. The averages of their single parameter pollution index are 30.25 , 19.79 and 8.74. The average of single parameter pollution index of the river is 8.23 which indicated that the river belongs to heavy pollution zone. The integrated water quality index was 22.5 showing that the river belongs to serious pollution zone.


Author(s):  
Jose Simmonds ◽  
Juan A. Gómez ◽  
Agapito Ledezma

This article contains a multivariate analysis (MV), data mining (DM) techniques and water quality index (WQI) metrics which were applied to a water quality dataset from three water quality monitoring stations in the Petaquilla River Basin, Panama, to understand the environmental stress on the river and to assess the feasibility for drinking. Principal Components and Factor Analysis (PCA/FA), indicated that the factors which changed the quality of the water for the two seasons differed. During the low flow season, water quality showed to be influenced by turbidity (NTU) and total suspended solids (TSS). For the high flow season, main changes on water quality were characterized by an inverse relation of NTU and TSS with electrical conductivity (EC) and chlorides (Cl), followed by sources of agricultural pollution. To complement the MV analysis, DM techniques like cluster analysis (CA) and classification (CLA) was applied and to assess the quality of the water for drinking, a WQI.


Author(s):  
Gilbert K. Gaboutloeloe ◽  
Gugu Molokwe ◽  
Benedict Kayombo

The impact of partially treated wastewater on the water quality of Notwane river stretch in the Gaborone region of Botswana was investigated. Water samples collected at effluent discharge point and three other sampling sites downstream were analyzed for pH, temperature, Biological Oxygen Demand (BOD5), Ammonia-nitrogen (Ammonia-N) and Nitrate-nitrogen (Nitrate-N). Sampling was conducted bi-weekly between February 2013 and April 2013. The ranges of measured parameters were:  pH (7.6-8.5), temperature (22-23ºC), BOD5 (11.2-27.0 mg/l), Ammonia-N (2.4-60.5 mg/l), Nitrate-N (20.6-28.6 mg/l). Analysis of variance, Games-Howel multiple comparisons and Pearson correlation were used to separate variable means. The results signal river non-point pollution due to runoff inflow of organics mainly from land use and domestic waste dumping by nearby dwellings. Temperature, BOD5, and pH range values were all within the Botswana Bureau of Standards (BOBS) limit while the maximum Ammonia-N and Nitrate-N were above BOBS limit by 50.5 mg/l and 6.6 mg/l, respectively. Regulations on indiscriminate waste dumping and discharge standards adherence should be enforced.


2018 ◽  
Vol 10 (1) ◽  
pp. 1 ◽  
Author(s):  
Susanti Oktavia Ningrum

The quality of wastewater sugar factory produced will affect the environmental health quality around the factory. The study aimed to analyze the quality of water river and the quality of wells around the Rejo Agung Baru sugar factory in the Madiun. This study is an descriptive observational. The samples comprised of 5 sampels of water rivers and 7 samples of well water. The results of the study at the quality of water river showed that there are parameters (BOD5 and temperature) unqualified with the quality standards based on the East Java Regional Regulation No. 2 of 2008 about Water Quality Management and Water Pollution Control in the East Java, the quality of water river is also affected by the waste water, trash, agricultural waste, and other pollutants. The result of measuring the quality of water well showed that there are parameters (organic substance) unqualified with quality standards based on Permenkes No: 416/Menkes/PER/ IX/1990 about the Terms and Water Quality Monitoring, the quality of Well water is also affected by the quality of water river, a distance of toilet, domestic wastewater and other pollutants. The quality of water river and the quality of well water have decreased that required supervision on the quality of a river water and the quality of water of a well.


Author(s):  
L. O. Bobor ◽  
C. M. Umeh

The indiscriminate disposal of industrial effluents and solid wastes in surface water bodies is detrimental to humans and aquatic organisms. Water quality monitoring is critical to identify pollutants of concern and develop effective management strategies. Hence, this study was conducted to assess the impact of waste disposal on the water quality of Aba Waterside River, Ogbor hill, Aba. Grab samples were collected upstream, midstream and downstream and some physicochemical and microbiological parameters were analyzed in accordance with standard methods for the analysis of water and wastewater. The results were compared with the Nigerian standard for drinking water quality and the national environmental effluent limitation regulations. Turbidity levels (10 -31mg/l) exceeded the maximum permissible levels for drinking water (5mg/l) and may be associated with higher levels of embedded disease-causing microbes and potentially harmful organic and inorganic substances. The biological oxygen demand midstream (1960mg/l) was remarkably high due to the effluent discharged from the abattoirs at that point. Fecal coliforms (3-198MPN/100ml) were detected in all samples, indicating the presence of other potentially harmful microorganisms. The findings of this study indicate that the water is unsuitable for direct drinking water purposes and stringent water quality control measures should be implemented.


2015 ◽  
Vol 16 (SE) ◽  
pp. 395-403
Author(s):  
Abbas Ghaffari Habib ◽  
Seyed Hadi Khatami

In Bahar County (Iran), rivers are among the important sources of water for the agricultural sector. Therefore, this research evaluated the parameters of temperature, pH, Total Dissolved Solids (TDS), turbidity, nitrate, total phosphate, dissolved oxygen (DO), Biological Oxygen Demand (BOD5), and fecal coliform at five stations for five months (from February 2015 to June 2015) to determine water quality in the rivers. Based on this evaluation, the NSFWQI index was calculated and, finally, the routes of the rivers were zoned. The best water quality was recorded at Station Number 3 with the NSFWQI Value of 80 in January, and the worst at Station Number 5 (latgah) with the NSFWQI Value of 37 in June. Based on the mean NSFWQI indices, water quality was Medium at Stations Number 1, 2, and 4, good at Station Number 3, and bad at Station number 5.


Author(s):  
Dhisney Gonçalves de Oliveira ◽  
Reinaldo Romero Vargas ◽  
Antonio Roberto Saad ◽  
Regina De Oliveira Moraes Arruda ◽  
Fabrício Bau Dalmas ◽  
...  

The urbanization process through which large urban centers have been passing has drastically affected the availability and especially the quality of water. The Cachoeirinha Invernada Watershed (CIW), located in the municipality of Guarulhos (State of São Paulo, Brazil), includes areas with different land use classes. This paper aims to correlate the spatial and temporal effects of land use and land cover on the water quality of the Cachoeirinha Invernada Watershed. In a period of 12 months and at six sampling points along the watershed, the physicochemical parameters temperature (T), pH, turbidity (TU), total solids (TS), electrical conductivity (EC), total phosphorus (TP), biochemical oxygen demand (BOD), as well as microbiological analysis (E. coli) were measured. Water quality was assessed using a modified version (WQIM) of the Water Quality Index (WQI) and the Trophic State Index (TSI). The areas surrounded by urban development presented a marked worsening in water quality, with the downstream point most affected and ranked as ‘POOR’. From the evaluated parameters, what contributed most to water quality degradation of the Cachoeirinha Invernada Watershed (CIW) was E. coli, followed by BOD, and TP, all parameters related to the presence of sewage in the water. The need for the construction of sewerage and waste treatment, protection and recovery of riparian forests, and environmental education regarding waste disposal are necessary to significantly improve the environmental quality of the Cachoeirinha Invernada Watershed.


Sign in / Sign up

Export Citation Format

Share Document