scholarly journals Quality of water sources in Southwestern Uganda using the compartment bag test (CBT): a cross-sectional descriptive study

2019 ◽  
Vol 9 (4) ◽  
pp. 683-693
Author(s):  
Richard Onyuthi Apecu ◽  
Lucas Ampaire ◽  
Edgar Mugema Mulogo ◽  
Fred Norman Bagenda ◽  
Afsatou Traore ◽  
...  

Abstract The aim of this study was to assess the bacteriological quality of water sources in the two rural areas of Uganda using the compartment bag test (CBT). In total, 200 water samples were collected from 69 different water sources and processed within 6 h of collection. Positive and negative controls were processed each day together with water samples. Physical parameters were measured in situ. Descriptive statistics were used to generate mean, minimum, maximum, standard deviations and percentages. The results indicated that 29% of the water sources met the National Standards and World Health Organization (WHO) Guidelines for drinking water. Sixty percent of the borehole, 44% of gravitational flow taps and 14% of roof rain water met the required standards. Of the open water sources, 75% of the rivers, 50% of open channels and 43% of unprotected dug wells plus 25% of protected springs and 9% of gravitational flow schemes had most probable number counts >100 Escherichia coli/100 mL of water. Most of the water sources in the study areas were not fit for human consumption without prior treatment. The CBT was found to be robust and easy to use in all field situations. The mean physical parameters of water sources were within the acceptable limits.

2014 ◽  
Vol 4 (3) ◽  
pp. 384-390 ◽  
Author(s):  
Bayeh Abera ◽  
Mulugeta Kibret ◽  
Goraw Goshu ◽  
Mulat Yimer

A cross-sectional study was conducted to determine the bacterial quality and antimicrobial susceptibility profiles of Enterobacteriaceae from drinking water in Bahir Dar city. A total of 140 water samples were collected in the wet and dry periods from springs (n = 4), reservoirs (n = 10) and private tap water at households (n = 126). Bacteriological analysis of water was conducted using multiple tube method. Overall, 21.4%, 18.6% and 17.8% of drinking water samples had total coliforms (TC), faecal coliforms (FC) and Escherichia coli, respectively. All spring water samples and 29.2% of private tap water had the highest TC load (18 most probable number/100 mL, 95% CI: 100). For FC, 81.4% of the drinking water supplies tested complied with both World Health Organization and Ethiopian Standards. High levels of resistance (98–100%) were observed for ampicillin by Enterobacteriaceae and Pseudomonas aeruginosa. All P. aeruginosa isolates and 20 (66.7%) of E. coli revealed multiple drug resistance. Enterobacteriaceae and P. aeruginosa isolates exhibited high levels of antimicrobial resistance. The bacterial quality of drinking water in Bahir Dar city was poor. Microbial surveillance and monitoring with periodic assessment on physical integrity of the water pipelines need to be undertaken.


2021 ◽  
Vol 28 (2) ◽  
pp. 81-88
Author(s):  
A.O. Adeleye ◽  
B. Kabiru ◽  
A.O. Amoo ◽  
F.K. Amoo ◽  
M. Raji ◽  
...  

Water from borehole source can be contaminated due to indiscriminate waste disposal. This pilot study was conducted to assess the bacteriological quality of water from five (5) hand-pump-fitted borehole sources present in Sabon Gari quarters in Ringim Local Government Area of Jigawa State. Presumptive, confirmed and completed tests were employed to determine total and faecal coliforms from the water samples using most probable number (MPN) technique. Bacterial isolates were identified by standard microbiologicalmethods. Results obtained indicate that all the water samples across all the dilution strengths tested recorded substantial growth of total coliforms at 37.3°C while faecal coliforms were observed at 44°C after incubation for 48 h. Using the MPN table, the five water samples assayed recorded 50 MPN/100mL, 14 MPN/100mL, 3 MPN/100mL, 5 MPN/100mL and 1 MPN/100mL. Results were also positive for gas and acid production in all samples collected characteristic of presence of E. coli. The results obtained in this study show bacterial contamination of the water from the boreholes which may constitute a public health risk. It is therefore recommended that the water pumped from these boreholes should be subjected to  adequate treatment to meet World Health Organization (WHO) required  standard for potable water meant for drinking. Keywords: Boreholes, hand pump, most probable number, total coliforms and faecal coliforms.


Author(s):  
Prajapati Shashikala R. S ◽  
Jadhav Anita S

This research is carried out to study the bacteriological biodiversity and quality of water during premonsoon, monsoon and post-monsoon in Panvel lakes, Maharashtra, India. Most Probable Number (MPN) count was carried out by using Mac Conkey’s broth in order to classify the lakes into different categories. Pathogenic bacteria colonies were isolated from water samples collected from different lakes, by spread plate method. After incubation, different colonies from incubated plates were picked; purified by repeated sub-culturing before being examined for gram reaction, microscopically bacteria were identified into positive or negative, cocci or bacilli, rod or spiral. Biochemical analysis was carried out using different tests. The results were analyzed using Bergey’s manual of systematic bacteriology. Many different types of bacteria were isolated from water samples that helped in classifying the lakes and knowing the bacterial loads of each lake.


2019 ◽  
Author(s):  
Goyitom Gebremedhn ◽  
Abera Aregawi Berhe ◽  
Abraham Aregay Desta ◽  
Lemlem Legesse

Abstract Background Fecal contamination of drinking water sources is the main cause of diarrhea with estimated incidence of 4.6 billion episodes and 2.2 million deaths every year. Methods A total of 145 water samples of different source type were collected from different areas in Tigray region from August 2018 to January 2019. The water samples from each site were selected purposively which involved sampling of water sources with the highest number of users and functionality status during the study period. Most Probable Number (MPN) protocol was used for the bacteriological analysis of the samples. Results A total of 145 water samples were collected from six zones in Tigray region, Ethiopia from August 2018 to January 2019. The study indicated that 63(43.5%) of the water samples were detected to have fecal coliform which is E.coli. In Mekelle city, which is the capital city of Tigray region, three in five 34(60.7%) of the collected samples were confirmed to have fecal coliform. Water samples from health facilities were 9.48 times [AOR=9.48, 95%CI: (1.59, 56.18)] more likely to have fecal coliform. Water samples from wells were 10.23 times [AOR=10.23, 95%CI: (2.74, 38.26)] more likely to have fecal coliform than water samples from Tap/Pipe. Similarly, water samples from hand pumps were 22.28 times [AOR=22.28, 95%CI: (1.26, 393.7)] more likely to have fecal coliform than water samples from Tap/Pipe. Water samples reported to be not chlorinated were 3.51 times [AOR=3.51, 95%CI: (1.35, 9.13)] more likely to have fecal coliform than water samples from chlorinated sources. Conclusion In this study all water source, including the chlorinated drinking water sources, were found highly contaminated with fecal origin bacteria. This may be mainly due to constructional defects, poor sanitation inspection, poor maintenance, intermittent water supply and irregular chlorination.


2015 ◽  
Vol 4 (1) ◽  
pp. 48-57 ◽  
Author(s):  
Mohammed Modu Aji ◽  
Shettima Abba Kyar ◽  
Mustapha Hussaini

 The study involved the determination of some physiochemical and bacteriological properties in sachet-water samples taken within selected geopolitical wards in Jere and Maiduguri Metropolis. The purpose was to ascertain the quality of sachet water sold for consumption within the area. Ten samples were drawn, five from each study area. The samples were analysed for temperature, colour, turbidity, pH, conductivity, iron, total alkalinity and total dissolved solid. Bacteriological analysis was also carried out using multiple tube (most probable number) technique for enumeration of both total coli form count and differential Escherichia coli count. Other physical examination like volume, National Agency for Food and Drugs Administration and Control (NAFDAC) registration number, batch number, production date and expiry date were also examined. The results obtained were compared with World Health Organization (WHO), NAFDAC and Nigeria Standard of Drinking Water Quality (NSDWQ). Variations were observed among the entire samples in comparison with the standard. Some of the parameters conform to the standard like the Tempreture, pH, colour, odour, iron content and NAFDAC registration number while others like TDS, total alkalinity and volumetric quantity fell below the standard. The bacteriological analysis also showed that 80% of the samples studied revealed the presence of coliforms. Hence, there is need for regulatory agencies like NAFDAC and Standard Organisation of Nigeria (SON) to intensify effort in the routine monitoring of quality of sachet water marketed for consumption.DOI: http://dx.doi.org/10.3126/ije.v4i1.12177 International Journal of Environment Volume-4, Issue-1, Dec-Feb 2014/15, page: 48-57  


2020 ◽  
Vol 36 (2) ◽  
pp. 75-77
Author(s):  
Anindita Bhowmik ◽  
Sunjukta Ahsan

Majority of the population of Bangladesh depend on tap or surface water as their source of water supply. This study was carried out to examine the microbial quality of both water and soil collected from different places using the multiple tube fermentation technique to determine coliform count by the most probable number (MPN) method in brilliant green lactose broth (BGLB) media.Inoculum from positive tubes of the presumptive test were further transferred on eosinemethylene blue (EMB) and MacConkey agar.The organisms isolated were further characterized using biochemical tests. Out of 93 water samples, 30 (32.26%) indicated the presence of lactose fermenter and gas producer in all 3 tubes of dilution series using inoculum quantities of 1.0, 0.1 and 0.01 ml, whereas out of 85 soil samples, 45 (52.94%) showed acid and gas production in all 3 tubes of dilution series.Among 85 soil samples, 40 samples that contained at least one positive in each dilution series and among 93 water samples, 31 samples that contained at least one positive in each dilution series were further re-identified with biochemical tests.This study showed 30.59% soil isolates and 26.88% water isolates were Escherichia coli which highlighted the fact that both water and soil act as a major reservoir of E.coli, which indicates possible fecal contamination as well as presence of potentially pathogenic E. coli. Bangladesh J Microbiol, Volume 36 Number 2 December 2019, pp 75-77


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Ruth Adi Agyo ◽  
Raph Agbo Ofukwu ◽  
Anthony Ekle J. Okoh ◽  
Charity A. Agada

Aim: This study aimed at examined the presence of coliform bacteria in private wells and boreholes (BH) in peri-urban areas of Makurdi, Benue State, Nigeria, using the approaches of most probable number (MPN) index and coliform count. Materials and Methods: Seven hundred and sixty-eight water samples were randomly collected during a 1-year period from non-cased wells, burn brick cased wells (BBW), concrete cased wells, and BH in four locations; A, B, C, and D during the wet and dry seasons. One liter of water was obtained from each well at every visit to the four sites, and eight water samples were collected from each visit. The samples were analyzed using multiple tube fermentation methods and pour plate techniques to determine the MPN of coliform/100 ml of water, reading from the MPN statistics table. Results: One-way analysis of variance statistics was applied using Duncan's new multiple range test to separate the means where there was a significant difference. The result revealed that the MPN index and total coliform counts in all the wells in the locations were above the World Health Organization (WHO) permissible limit for potable water. The highest MPN index of 54.807 was recorded in Location A and followed by 42.679 in Location B. The MPN index in Locations C and D was 36.740 and 30.943, respectively. There was significantly (p=0.000) higher total coliform count in the wet season (41.48±7.09) than in the dry season (38.33±2.83). Conclusion: This study shows the presence of coliform bacteria isolates in all the wells and BH that exceeded the WHO permissible limits for drinking water. The water from these sources is unsafe for drinking except after dosing with appropriate germicides. Sensitization of the population on the actions they can take to make the water safe for domestic use is suggested.


2021 ◽  
Vol 23 (2) ◽  
pp. 146-152
Author(s):  
Bharati Shakya ◽  
Supri Raj Shrestha ◽  
Vinutha Silvanus

Water safety and quality are fundamental to human development and well-being. Yet, at least 2 billion people are using a drinking water source contaminated with feces worldwide. This study was conducted to assess the types of water supply, storage and methods of purification of drinking water and to examine the bacteriological quality of supplied and drinking water at household level by most probable number (MPN) test in Makalbari area in Gokarneshwor Municipality, Kathmandu. A total of 80 households were selected using simple random sampling technique and two samples (one from main water supply and another from drinking water, n=160 water samples) were collected from each household. Ethical clearance was taken from the Nepal Medical College Institutional Review Committee. SPSS version 16.0 was used for statistical analysis. Majority of water supply samples 65 (81.2%) were from tap, 11 (13.8%) were from well and 4 (5.0%) samples were from bore well. Bacteriologically, of the total water supply samples, 34 (42.5%) samples were excellent, 16 (20.0%) samples were suspicious and 30 (37.5%) samples were unsatisfactory by MPN index quality. Most of the households stored drinking water in the tanks 34 (42.5%). Most of the water samples 29 (36.3%) were directly consumed from the water supply without purification. Among the directly consumed drinking water samples, 13 (44.8%) samples showed unsatisfactory MPN index. Most commonly used methods of water purification was filtration 21 (26.2%). Of the total drinking water samples, 33 (41.25%) samples were positive for total coliform. Thirty-two (40.0%) of the households reported diarrhea in past one year. A highly significant association was found between MPN index of drinking water and occurrence of diarrhea in the households. The quality of the most of the water samples from water supply and drinking water were unsatisfactory. Inspite of this, drinking water was not purified in some of the households. Moreover, few of the drinking water samples were not potable even after purification. Therefore, community should be made aware to improve quality of drinking water in households.


2019 ◽  
Vol 1 ◽  
pp. 1-8
Author(s):  
E M Mbaawuaga ◽  
W C Agber ◽  
M W Kar

Assessment of the efficacy of Water-Care in the treatment of water to safe health level was carried out on water samples from different water sources within six populated communities of Makurdi Metropolis. Thirty six (36) water samples were collected and treated with WaterCare based on the product manufacturer’s instructions. Treated water stored for 30 minutes and 24 hours were tested for coliforms using Multiple Tube Fermentation technique. Analysis of variance (ANOVA) was used with the Tukey Honestly Significant Difference (HSD) for multiple comparisons of the data variables. Most probable Number (MPN) of coliforms /100mL of sampled water ranged from 43 to >1,100cfu/100ml. Mean MPN of treated water for30 minutes and 24 hours interval was 37.7±33.0cfu/100ml and 16.17±14.8cfu/100ml respectively. Improved/deep sources such as boreholes show 3cfu/100ml and 0cfu/100ml respectively for 30 minutes and 24 hours treatment while unimproved/shallow sources such as wells show ≤120 cfu/100ml and ≤53 cfu/100ml respectively for 30 minutes and 24 hour interval. A significant difference between treated samples and the untreated was observed (F = 6.321, P = 0.005). Tukey multiple comparison test revealed that MPN index/100ml in the water samples was significantly lower (P =0.015, P =0.009) after treating for 30 minutes and 24 hour time interval respectively as compared to untreated water. But there was no significant difference between the 30 minute and 24 hour time interval (P =0.970). The study found that, drinking water sources in Makurdi Township were heavily contaminated, and that 30 minutes and 24 hours’ time interval was not a sufficient time for total elimination of bacteria contaminants after treatment with WaterCare. Future research should ascertain the actual treatment time for inactivation of all bacteria in water treated with WaterCare.