scholarly journals Optical ray tracing-guided myopic laser in situ keratomileusis: 1-year clinical outcomes

2013 ◽  
pp. 1181 ◽  
Author(s):  
Arthur Cummings ◽  
Kelly
2012 ◽  
Vol 38 (1) ◽  
pp. 28-34 ◽  
Author(s):  
Silvia Schumacher ◽  
Theo Seiler ◽  
Arthur Cummings ◽  
Matthias Maus ◽  
Michael Mrochen

2015 ◽  
Vol 41 (5) ◽  
pp. 1030-1037 ◽  
Author(s):  
Carmen Canovas ◽  
Marrie van der Mooren ◽  
Robert Rosén ◽  
Patricia A. Piers ◽  
Li Wang ◽  
...  

2013 ◽  
Vol 42 (4) ◽  
pp. 323-333 ◽  
Author(s):  
Daizong Wen ◽  
Jinhai Huang ◽  
Xuexi Li ◽  
Giacomo Savini ◽  
Yifan Feng ◽  
...  

2003 ◽  
Vol 29 (8) ◽  
pp. 1507-1513 ◽  
Author(s):  
Daisuke Aizawa ◽  
Kimiya Shimizu ◽  
Mari Komatsu ◽  
Misae Ito ◽  
Masanobu Suzuki ◽  
...  

2015 ◽  
pp. 1291 ◽  
Author(s):  
Steven Schallhorn ◽  
Jan Venter ◽  
Stephen Hannan ◽  
Keith Hettinger

2002 ◽  
Vol 18 (3) ◽  
Author(s):  
Dolores Ortiz ◽  
José M Saiz ◽  
Francisco González ◽  
José N Fernández Del Cotero ◽  
Fernando Moreno

2001 ◽  
Vol 17 (3) ◽  
pp. 305-309
Author(s):  
Jose N Fernández del Cotero ◽  
Fernando Moreno ◽  
Dolores Ortiz ◽  
Enrique Vélez ◽  
Francisco González ◽  
...  

2021 ◽  
Vol 14 (5) ◽  
pp. 737-743
Author(s):  
Zheng Jiang ◽  
◽  
Dong-Qiang Luo ◽  
Jiao Chen ◽  
◽  
...  

AIM: To compare clinical outcomes and refractive stability of implantable collamer lens (ICL) implantation and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia correction. METHODS: The Optical Quality Analysis System (OQAS) was used to evaluate clinical outcomes objectively after operation for high myopia correction. We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), safety index, efficacy index, spherical equivalent, modulation transfer function (MTF) cutoff frequency, strehl ratio (SR) and objective scatter index (OSI). RESULTS: At 1y postoperatively, the safety indices were 1.33±0.27 in ICL group, and 1.17±0.24 in FS-LASIK group. 39.58% in the ICL group and 27.59% in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA. The efficacy indices were 1.28±0.22 in ICL group, and 1.13±0.26 in FS-LASIK group. The changes of spherical equivalent from 1wk to 1y postoperatively was -0.12±0.37 D in ICL group, and -0.79±0.58 D in FS-LASIK group (P<0.05). Spherical equivalent within ±0.50 D was achieved in 97.92% in ICL group and 68.97% in FS-LASIK group. MTF cutoff frequency were higher with ICL as compared to FS-LASIK (P<0.05) at each postoperative follow-up stage; for postoperative 1mo later, SR was statistically significant difference between two groups (P<0.05); with no statistically significant difference in OSI between two groups (P>0.05) in postoperative 3mo later. CONCLUSION: ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction. ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK.


Sign in / Sign up

Export Citation Format

Share Document