scholarly journals APPLYING INTERNAL CIRCULATION ANAEROBIC REACTOR FOR WASTEWATER TREATMENT: A CASE STUDY IN SAIGON PAPER MILL WASTEWATER TREATMENT PLANT

2019 ◽  
Vol 12 (3) ◽  
pp. 145-151
Author(s):  
Nhat-Ha TRAN ◽  
Manh-Ha BUI
2004 ◽  
Vol 49 (1) ◽  
pp. 9-14 ◽  
Author(s):  
G. Langergraber ◽  
N. Fleischmann ◽  
F. Hofstaedter ◽  
A. Weingartner

A submersible UV/VIS spectrometer was used to monitor a paper mill wastewater treatment plant. It utilises the UV/VIS range (200-750 nm) for simultaneous measurement of COD, filtered COD, TSS and nitrate with just a single instrument. The instrument measures in-situ, directly in the process. Paper mill wastewater shows typical and reproducible spectra at various process measuring points. There is a relative maximum at 280 mm due to the absorbance by dissolved organic substances, mainly ligninic acids. Comparison of absorbance spectra distinctly shows the decrease of this peak, indicating biological degradation throughout the treatment process. Summarising, one can say that paper mill wastewater cannot be monitored by a simple UV probe measuring only the absorbance at a single wavelength. The required information can only be gained from the whole spectra. Regarding plant control it is suggested that only the overall spectral information is used. Calibrations to conventional parameters are now merely carried out for purposes of reference-checking.


2001 ◽  
Vol 44 (2-3) ◽  
pp. 235-242 ◽  
Author(s):  
B. De heyder ◽  
P. Ockier ◽  
R. Jansen ◽  
R. Huiberts

Several process units at a wastewater treatment plant (WWTP) can produce a significant level of sound and thus induce sound nuisance for nearby residents. The risk for sound nuisance should be considered by making a prognosis of sound impact in an early project phase (planning, design). A prognosis requires information with respect to the sound characteristics of the different process units. This paper reports the development of empirical models for the sound power of relevant process units in the water line at Aquafin WWTPs. The used methodology for model derivation and validation allowed us to minimize the required number of measurements. Besides the methodology, the paper describes in detail the derivation and validation of the empirical model for the splashing water of screw pumps. Also the use of all the derived empirical models to determine the sound impact of a wastewater treatment plant at close distance is illustrated with a case-study.


2012 ◽  
Vol 66 (8) ◽  
pp. 1684-1690 ◽  
Author(s):  
Russell Yap ◽  
Michael Holmes ◽  
William Peirson ◽  
Michael Whittaker ◽  
Richard Stuetz ◽  
...  

Dissolved air flotation (DAF) incorporating filtration (DAFF) is used at the Bolivar wastewater treatment plant (WWTP) to polish lagoon effluent for reuse. Elevated algal populations are frequently experienced and can lead to increased coagulant requirements and process control issues. Streaming current detectors (SCDs) and a charge demand analyser (CDA) were used to monitor the full-scale plant. This was followed by an optimisation study using a pilot plant with a CDA. It was found that the normal operational charge demand range for DAF at Bolivar was between −46 and −40 μeq L−1. Decreasing the pH of coagulation reduced coagulant consumption and facilitated more sensitive CDA responses to changes in alum dose.


Water SA ◽  
2018 ◽  
Vol 44 (4 October) ◽  
Author(s):  
Tilik Tena Wondim ◽  
Bloodless Dzwairo

The challenge of selecting an appropriate wastewater treatment plant (WWTP) site is addressed in this study, using the case study of Bahir Dar City, Ethiopia. An innovative approach is proposed for selecting the WWTP site. Fifteen practically feasible alternatives were identified based on the geographical information system (GIS) based hydraulic design and considering the overall economy of the system. The three dimensions of sustainability were considered while evaluatingalternatives through incorporating economic, social, energy and environmental criteria in decision-making. The multiple attribute decision making (MADM) method was applied to prioritize the alternatives. Four scenarios representing the different perspectives of choices were used for weight elicitation. The results of the study show that the developed decisionmaking approach identified practically feasible alternatives. The framework and decision-making methodology developed in this study helped to facilitate the decision making by local government in a holistic view that incorporates environmental management in the city of Bahir Dar.


2019 ◽  
Vol 11 (3) ◽  
pp. 622 ◽  
Author(s):  
Isabella Pecorini ◽  
Francesco Baldi ◽  
Renato Iannelli

Four inocula collected from different operating facilities were tested in their hydrogenic performances by means of two biochemical hydrogen potential test set-ups using sucrose and food waste as substrates, with the aim of evaluating the influence of inoculum media in batch fermentative assays. The selected inocula were: activated sludge collected from the aerobic unit of a municipal wastewater treatment plant, digested sludge from an anaerobic reactor treating organic waste and cattle manure, digested sludge from an anaerobic reactor treating agroindustrial residues, and digested sludge from an anaerobic reactor of a municipal wastewater treatment plant. Test results, in terms of specific hydrogen production, hydrogen conversion efficiency, and volatile solids removal efficiency, were significantly dependent on the type of inoculum. Statistical analysis showed different results, indicating that findings were due to the different inocula used in the tests. In particular, assays performed with activated sludge showed the highest performances for both substrates and both experimental set-ups.


Sign in / Sign up

Export Citation Format

Share Document