Basic Studies of Gases for Fast Switches

Author(s):  
S. R. Hunter ◽  
L. G. Christophorou
Keyword(s):  
1977 ◽  
Vol 16 (01) ◽  
pp. 36-41 ◽  
Author(s):  
T. Machida ◽  
M. Miki ◽  
M. Ueda ◽  
A. Tanaka ◽  
I. Ikeda

SummaryVarious renal imaging agents that were reported in the past and a new agent, 99mTc-malate as well as 99mTc-cystein acetazolamide complex were prepared using electrolysis and electrochemical methods. These were studied for their labelling efficiency. After animal experiments with selected 99mTc-com- pounds, 99mTc-rnalate proved to be sufficient for renal imaging with adequate concentration. 99mTcmalate differs from other renal imaging agents in the utilization of endogeneous metabolic product.The first half time of 99mTc-malate in humans is 17 minutes, on the average, and the urinary excretion rate of 99mTc-malate is 36±6.05% in 1 hour after intravenous administration, 44 ± 3.41% in 2 hours and 50 + 5.62% in 3 hours.In our 40 clinical experiences of 99m-Tc-rnalate, most cases demonstrated quite clear renal images in the serial scintiphotos except cases whose serum creatinines were over 4.5 mg/dl.


1993 ◽  
Vol 70 (01) ◽  
pp. 202-203 ◽  
Author(s):  
Elizabeth G Nabel ◽  
Gary J Nabel

2000 ◽  
Author(s):  
P. M. Tentzepis ◽  
P. Chen ◽  
I. V. Tomov ◽  
A. S. Dvornikov ◽  
D. A. Oulianov

1991 ◽  
Vol 23 (4-6) ◽  
pp. 641-650 ◽  
Author(s):  
S. Haruta ◽  
T. Takahashi ◽  
T. Nishiguchi

The authors have developed what we call the submerged iron contactor process as a simple and inexpensive phosphorus removal method for small-scale plants disposing of domestic wastewater and household wastewater treatment tanks. In this method iron contactors are submerged in biological treatment tanks, where phosphate anions in wastewater are combined with iron cations produced through corrosion of the contactors, and the compound thus produced is precipitated and removed together with biological sludge. In these studies, laboratory experiments were made on the contact aeration process combined with the above-mentioned method, and the following findings were obtained. (1) It is desirable to treat wastewater by making use of corrosion by sulfate-reducing bacteria instead of corrosion by oxygen dissolved in wastewater, to conduct a stable phosphorus removal by this combined method. (2) The corrosion rate of iron contactors is affected by the volumetric loading of BOD in the tanks where they are submerged. (3) Assuming that an iron contactor continues to suffer corrosion evenly all over the surface when our combined method is applied, it is estimated that the corrosion rate is about 1mm or less in 30 years.


Sign in / Sign up

Export Citation Format

Share Document