Precise Joint Length Determination Using A Multiple Casing Collar Locator Tool

1974 ◽  
Author(s):  
R.A. Ruedrich ◽  
T.K. Perkins ◽  
D.E. O'Brien
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bestoon Mohammed Faraj

Abstract Background Radiographic analysis of tooth morphology is mandatory for accurate calibration of the degree of canal curvature angle and radiographic working length to its real dimensions in case difficulty assessment protocols. This study aimed to determine the impact of the degree of root canal curvature angle on maintaining the real working length and the original canal axis of prepared root canals using a reciprocating rotary instrumentation technique. Methods Radiographic image analysis was performed on 60 extracted single-rooted human premolar teeth with a moderate canal curvature (10°–25°) and severe canal curvature (26°–70°). Working length and longitudinal canal axis were determined using cone-beam computed tomography (CBCT) and digital periapical radiography. The real canal length was determined by subtracting 0.5 mm from the actual canal length. Root canals were prepared using the WaveOne Gold reciprocating file (Dentsply Maillefer, Ballaigues, Switzerland). Results There was no significant relation of the degree of canal curvature angle to the accuracy of radiographic working length estimated on CBCT and digital periapical radiographic techniques (P > 0.05). Postinstrumentation changes in the original canal axis between moderate and severe canal curvature angles, assessed on CBCT and periapical digital radiographic images were statistically non-significant (P > 0.05). Conclusions A standardized digital periapical radiographic method performed similarly to the CBCT technique near to its true working length. No significant interaction exists between the diagnostic working length estimation, postoperative root canal axis modification, and the degree of canal curvature angle, using reciprocating rotary instrumentation technique.


1991 ◽  
Vol 69 (3-4) ◽  
pp. 538-542 ◽  
Author(s):  
C. H. Champness ◽  
Z. A. Shukri ◽  
C. H. Chan

In Se–CdO photovoltaic cells, the electron diffusion length Ln in the selenium absorber layer has been determined from measurements of capacitance C and photocurrent under monochromatic illumination by variation of applied reverse bias. If penetrating incident light of band-gap wavelength is used, a plot against 1/C of the illuminated-to-dark current change ΔI yields a straight line over a certain range of bias values. Extrapolation of this line to the 1/C axis yields Ln. It was found in the fabrication of the Se–CdO cells that increasing the substrate temperature from 100 to 140 °C during the selenium deposition resulted in an increase in the cell photovoltaic output. Capacitance and ΔI measurements on these cells showed an increase in diffusion length with substrate temperature, indicating that the increased cell performance was due to improved electron collection in the selenium layer.


IAWA Journal ◽  
1983 ◽  
Vol 4 (4) ◽  
pp. 245-247 ◽  
Author(s):  
A. P. Wilkins ◽  
R. K. Bamber

A comparison has been made between the method of Ladell, in which tangential longitudinal sections are used for the determination of mean tracheid length and the traditional method using macerated wood. The two methods produced identical results. Ladell's method was quicker, enabled precise location of measured cells and required less sample preparation.


2010 ◽  
Vol 36 (3) ◽  
pp. 105-108 ◽  
Author(s):  
Paulo Nelson-Filho ◽  
Marcela Pacífico Lucisano ◽  
Mário Roberto Leonardo ◽  
Raquel Assed Bezerra Da Silva ◽  
Léa Assed Bezerra Da Silva

Author(s):  
M.-A. Cantin ◽  
Y. Savaria ◽  
Prodanos ◽  
P. Lavoie

Dental Update ◽  
2008 ◽  
Vol 35 (10) ◽  
pp. 678-683 ◽  
Author(s):  
Stephen Robinson ◽  
Paul A Brunton
Keyword(s):  

2016 ◽  
Vol 64 (3) ◽  
pp. 244-249
Author(s):  
Fernanda Mara Paiva BERTOLI ◽  
Carolina Dea BRUZAMOLIN ◽  
Flares BARATTO FILHO ◽  
Débora Andrade da SILVA ◽  
Flávia Fagundes Sens TOMAZINHO ◽  
...  

ABSTRACT Objective: The aim of the study was to evaluate performance of digital radiographic and two electronic apex locators, Propex II and Root ZX in root canal length determination in primary molars. Methods: 25 primary molars were divided into two groups, G1 without root resorption and G2 with root resorption. The exams were performed using all methods by two experienced examiners, with 1-week interval. The gold standard was determined by visual examination. The methods were statistically analyzed regarding the values of reproducibility and correlated with the gold standard by Pearson´s correlation coefficient. Results: The root canal length determination coincided with gold standard in 22.7% for Root ZX, 17.5% for Propex II and 12.5% for digital radiography. Correlation values were higher in G1, the Root ZX presented the highest values. In G2 the digital radiography showed the lowest correlation. In G1, the intra-examiner reproducibility values ranged from 0.925 to 0.523, and interexaminer 0.863 to 0.670. In G2, the values of intra-examiner reproducibility ranges from 0.864 to 0.097, and inter was 0.774 to 0.379. Conclusion: It was concluded that the methods performance varying according to examiner's experience. The Root ZX presented the highest reproducibility and accuracy.


Holzforschung ◽  
2017 ◽  
Vol 71 (9) ◽  
pp. 713-723 ◽  
Author(s):  
Francisco Arriaga ◽  
Daniel F. Llana ◽  
Miguel Esteban ◽  
Guillermo Íñiguez-González

Abstract The mechanical properties of timber can be estimated from wave propagation velocity by measuring wave time-of-flight (ToF). However, a time-lag complicates the measurements, which produces an apparent velocity dependency on length and this species and instrument dependent property is also influenced by knottiness. This research is dealing with time-lag determination by different sensor positioning in situ ToF measurements. ToF longitudinal measurements were conducted on 120 90 mm×140 mm specimens of the coniferous species radiata pine, Scots pine, laricio pine and maritime pine. The following commercially available acoustic devices were used: Sylvatest Duo, USLab, and Microsecond Timer. The sensors were arranged for the measurement types “end-to-end”, “on the same surface” and “on opposite surfaces”. ToF data were obtained from the full-length (4 m) specimens and then from the same specimens shortened to 3 m, 2 m and 1 m in length. The in situ procedures of ToF are applicable for a reliable length determination independently from the time-lag (tL) and velocity. The differences observed by end-to-end measurements, with respect to velocity, are below 4.4%. A velocity correction factor can be deduced for each instrument, which is independent of species.


Sign in / Sign up

Export Citation Format

Share Document