Electrical Energy Savings in NGL Extraction Plant by Implementing ON/OFF Sequence Logic Control for Fin Fan Coolers

2018 ◽  
Author(s):  
Rashed Bametraf
2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


AGROINTEK ◽  
2017 ◽  
Vol 11 (2) ◽  
pp. 75
Author(s):  
Lukman Hidayat ◽  
Fitri Electrika Dewi Surawan ◽  
Arga Harianda Lumban Raja

Increasing demand for Crude Palm Oil (CPO) as the vegetable oil was causing the industry to cultivate palm oil increased, so that the energy required to produce CPO also increased. The purpose of this study is to identify the type, source and calculate the amount of energy needs, calculate the level of efficiency and energy savings opportunities. Stages of the research are  initial energy analysis, a detailed energy, and energy analysis in processing systems. Based on the research results, to produce each kg of CPO processing capacity of 60 ton TBS / hour with a recovery rate of 20.59% of primary energy needs of 16.200679 MJ / kg. Real boiler efficiency of 45.69%, the real efficiency of the turbine was 94, 86%. Turbine efficiency  to generate electrical energy by 1.09%, the technical efficiency of 66.80% turbines, diesel generators technical efficiency of 47.25%, the technical efficiency of electric motors by 59.37%.  The total efficiency  of  electricity  use by 4,75%, the efficiency of diesel estate of 1.379% and the efficiency of the use of steam at 93.77%. Energy can be saved by 0.0442 MJ / kg with a description of human powered energy of 0.0004316 MJ / kg, energy electrical energy by .04372 MJ / kg. While energy can be stored on the excess energy to fuel biomass boiler was 1.45 MJ / kg


2018 ◽  
Vol 9 (1) ◽  
pp. 1-7
Author(s):  
Redaksi Tim Jurnal

PT PJB Muara Karang power plant is an industry with a large electrical energy consumption for auxiliary power. In ISO50001 itensitas Energy Consumption (IKE) is a great need to audit energy consumption. In the contract the company's performance also set a percentage of personal use should not exceed 6% of the electricity production. Currently Posentase usage of own consumption at power plant unit 5 is greater than the power plant unit 4. It is necessary for an energy audit for the usage of its own in order to decrease the percentage of personal use in the power plant 5 0.5% of the current conditions and find energy savings opportunities in the power plant unit 5.To analyze this problem using energy audits, analyzes the performance test method using "gate cycle" and testing the quality of the voltage source by using the power quality measurement analysis. Having found the equipment with the largest energy comsumtion fish bone tools used to find the main cause of this disorder.


Solar Energy ◽  
2004 ◽  
Author(s):  
Mostafa Abd El Mohimen ◽  
George Hanna ◽  
Moncef Krarti

This paper summarizes the results of a simulation analysis to determine the effectiveness of daylighting in reducing electrical energy consumption for office buildings in Egypt. Specifically, the impact on daylighting performance is investigated of window size, building size, daylighting control, and glazing type for three geographical locations in Egypt. It was determined that a window to wall area ratio of 0.20 minimizes the total annual electricity use for office buildings in three Egyptian locations, Cairo, Alexandria, and Aswan. A simplified analysis method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.


Solar Energy ◽  
2005 ◽  
Author(s):  
Abdelkarim Nemri ◽  
Moncef Krarti

This paper provides a simplified analysis tool to assess the energy saving potential of daylighting for commercial buildings through skylights. Specifically, the impact of daylighting is investigated for various fenestration opening sizes, glazing types, control strategies, and geographic locations. A top floor of a prototypical office building has been considered in the analysis. The results obtained for the office building can be applied to other types of buildings such as retails stores, schools, and warehouses. Based on the simulation analysis results, it was determined that skylight to floor ratio more than 0.3 does not affect significantly the lighting energy savings. An optimum value of skylight to floor area ratio was found to be 0.2 to minimize the annual total building energy use.


1998 ◽  
Vol 38 (3) ◽  
pp. 209-217 ◽  
Author(s):  
J. Ferrer ◽  
M. A. Rodrigo ◽  
A. Seco ◽  
J. M. Penya-roja

An aeration fuzzy logic based control system has been developed and tested in the main aerobic reactor of a BARDENPHO process pilot plant. This system has been compared with two ordinary aeration process controllers: one- and two-aeration-level on/off controllers. Energy savings of about 40% over the one-level on/off controller and a more stable closed-loop response have been obtained. Thus, an improvement of about 60% in average deviation can be accomplished by the use of an AFLBC.


1980 ◽  
Vol 194 (1) ◽  
pp. 279-289 ◽  
Author(s):  
D. Clifford ◽  
R. Coates ◽  
A. Park

Plant currently under construction for repowering Slough Estates is described. This will not only provide the basis for replacement of ageing plant, but will enable the existing steam turbines to work as part of a high efficiency cycle. The principles relating to the combined generation of steam and electrical energy are reviewed for existing and possible plant configurations, with a view to optimizing the energy conversion. The choice of a gas turbine and fully fired heat recovery boiler to provide extra power plus steam for existing purposes is shown to be justified by the savings in fuel and other operating costs over a typical year's operation. The new plant will burn gas, residual oil or distillate oil, and fuel treatment plant is an essential part of the equipment. The energy savings indicated using technology already available in Britain point the way to future developments.


1982 ◽  
Vol 104 (2) ◽  
pp. 170-173
Author(s):  
D. P. Shea ◽  
J. E. Shelton ◽  
T. L. White

A large direct industrial refrigeration system was installed to reduce energy consumption in a chemical process plant. Electrical energy was saved by eliminating an intermediate cooling circuit including chilled liquid heat exchangers and glycol circulating pumps. A benefit of the system was increased production capacity by improving evaporator heat transfer, which reduced batch cycle time. This paper discusses system design, start-up and operating experience, and energy savings.


Urban Climate ◽  
2015 ◽  
Vol 14 ◽  
pp. 315-325 ◽  
Author(s):  
Melvin Pomerantz ◽  
Pablo J. Rosado ◽  
Ronnen Levinson

Sign in / Sign up

Export Citation Format

Share Document