scholarly journals A MORPHOMETRIC STUDY OF THE THYROID GLAND IN HUMAN CADAVERS

2018 ◽  
Vol 6 (4.1) ◽  
pp. 5783-5787
Author(s):  
Shobha Gaikwad ◽  
◽  
Rajani Joshi ◽  
2018 ◽  
Vol 67 ◽  
pp. S21
Author(s):  
Rajiv Kumar Verma ◽  
Pratima Jaiswal ◽  
Kunjbihari Rathore ◽  
William F. Masih

1996 ◽  
Vol 45 (4) ◽  
pp. 385-388 ◽  
Author(s):  
Tomo INOMATA ◽  
Hiroyoshi NINOMIYA ◽  
Shizuo KAWAKAMI ◽  
Kazuko SAKAGUCHI ◽  
Katsuyasu SAKITA ◽  
...  

Author(s):  
Raghavendra ◽  
VS Shirol ◽  
Daksha Dixit ◽  
Y Anil Kumar Reddy ◽  
SP Desai

Endocrinology ◽  
1980 ◽  
Vol 107 (4) ◽  
pp. 1249-1257 ◽  
Author(s):  
J.-F. DENEF ◽  
A. C. CORDIER ◽  
S. HAUMONT ◽  
C. BECKERS

2013 ◽  
Vol 2 (2) ◽  
pp. 81-84
Author(s):  
Abu Sadat Mohammad Nurunnabi ◽  
S Mahbub ◽  
HA Perven ◽  
S Ara

Background: The position and size of isthmus of thyroid vary greatly in humans, and sometimes it is absent. The present study was designed to find out the difference in isthmus of the thyroid gland of Bangladeshi people in relation to age and sex. Methods: The cross-sectional, descriptive study was performed in the Department of Anatomy, Dhaka Medical College, Dhaka, from January to December 2008, on 73 post mortem human thyroid gland collected from unclaimed dead bodies. Isthmus was found in 60 cases. The samples having the isthmus (n=60) were divided into three age-groups including group A (10-20 years), group B (21-50 years) & group C (>50 years) and the isthmus was cut off from the thyroid gland, then its length, breadth and thickness were measured and recorded. Results: The isthmus of the thyroid gland was found in 82.2% cases. It extended from 2nd to 4th tracheal ring in 91.7% and from 2nd to 5th ring in 8.3% cases. No difference was found in length, breadth and thickness of the isthmus of the thyroid gland in between males and females. However, difference was found in breadth between group A & B (p<0.05) and A & C (p<0.01) and in thickness between group B & C (p<0.05). Conclusion: The presence or absence, positional change and variation in gross dimension of the thyroid isthmus were evident in humans. The morphological difference was found with increasing age but not with sex. Nepal Journal of Medical Sciences | Volume 02 | Number 02 | July-December 2013 | Page 81-84 DOI: http://dx.doi.org/10.3126/njms.v2i2.8940


2018 ◽  
Vol 6 (3.3) ◽  
pp. 5605-5612
Author(s):  
Manisha Randhir Dhobale ◽  
◽  
Nitin Radhakishan Mudiraj ◽  
Medha Girish Puranik ◽  
◽  
...  

2013 ◽  
Vol 03 (04) ◽  
pp. 078-081
Author(s):  
Raghavendra A. Y. ◽  
Arunachalam Kumar ◽  
Pratik Tarvadi ◽  
Harsha C. R. ◽  

AbstractModerator band is a muscular trabecula which extends from interventricular septal wall to the base of anterior papillary muscle in right ventricle of heart. This study was conducted on 20 hearts from adult human cadavers. Out of 20 specimens of heart we could observe the presence of moderator band in 17 and in rest 3 it was not visible for record. Origin length, thickness and distance from tricuspid valve were noted. The average length of the moderator band was 13.82cm with the SD of 3.94 and the average thickness being 4.46cm with the SD of 1.36. The average distance from tricuspid valve was 3.6cm with the SD of 1.01. As the moderator bands, or other large trabeculations, can be major obstacle for the repair of apical ventricular septal defects, the morphometric study of moderator band may help the surgeons during surgical procedures conducted for correction of such defects.


2019 ◽  
Vol 7 (1.1) ◽  
pp. 6119-6122
Author(s):  
Bhavin B. Kodiyatar ◽  
◽  
Shital Bhishma Hathila ◽  
Maitreyee Mangesh Kulkarni ◽  
Shilpa K Patel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document