scholarly journals High Viral Load in the Planthopper Vector Delphacodes kuscheli (Hemiptera: Delphacidae) is Associated With Successful Transmission of Mal de Río Cuarto Virus

2013 ◽  
Vol 106 (2) ◽  
pp. 3-3
2013 ◽  
Vol 106 (1) ◽  
pp. 93-99 ◽  
Author(s):  
Evangelina B. Argüello Caro ◽  
Guillermo A. Maroniche ◽  
Analía D. Dumón ◽  
Mónica B. Sagadín ◽  
Mariana Del Vas ◽  
...  

2018 ◽  
Vol 1 (3) ◽  
pp. 1-8
Author(s):  
Naichaya Chamroonkul

Even with two decades of widespread using hepatitis B vaccination, chronic hepatitis B remains a major global health problem. In Thailand, the prevalence of chronic hepatitis B infection was down from 8 - 10% in last decade to 5% recently. Failure to control mother to child transmission is one of the important barriers to the total elimination of hepatitis B infection from world population. In the majority, vertical transmission can be prevented with a universal screening program, immunoprophylaxis by administration of hepatitis B vaccine and hepatitis B immunoglobulin (HBIg) for babies born to mothers with HBV. However, in mothers with a high viral load, the chance of immunoprophylaxis failure remains high. To date, there are standard recommendations by all international liver societies including AASLD, EASL and APASL suggest introducing an antiviral agent during the third trimester to CHB pregnant women with a high viral load. Previous US FDA pregnancy category B agents such as Tenofovir and Telbivudine are allowed through all trimesters of pregnancy and are effective for prevention of mother to child transmission. Breastfeeding for patients who receive antiviral agents can be allowed after a risk-benefit discussion with the patient and family.


Perfusion ◽  
2021 ◽  
pp. 026765912098653
Author(s):  
Hafiz Naderi ◽  
Shaun Robinson ◽  
Martin J Swaans ◽  
Nina Bual ◽  
Wing-See Cheung ◽  
...  

The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.


BMJ ◽  
2021 ◽  
pp. n1637 ◽  
Author(s):  
Marta García-Fiñana ◽  
David M Hughes ◽  
Christopher P Cheyne ◽  
Girvan Burnside ◽  
Mark Stockbridge ◽  
...  

Abstract Objective To assess the performance of the SARS-CoV-2 antigen rapid lateral flow test (LFT) versus polymerase chain reaction testing in the asymptomatic general population attending testing centres. Design Observational cohort study. Setting Community LFT pilot at covid-19 testing sites in Liverpool, UK. Participants 5869 asymptomatic adults (≥18 years) voluntarily attending one of 48 testing sites during 6-29 November 2020. Interventions Participants were tested using both an Innova LFT and a quantitative reverse-transcriptase polymerase chain reaction (RT-qPCR) test based on supervised self-administered swabbing at testing sites. Main outcome measures Sensitivity, specificity, and predictive values of LFT compared with RT-qPCR in an epidemic steady state of covid-19 among adults with no classic symptoms of the disease. Results Of 5869 test results, 22 (0.4%) LFT results and 343 (5.8%) RT-qPCR results were void (that is, when the control line fails to appear within 30 minutes). Excluding the void results, the LFT versus RT-qPCR showed a sensitivity of 40.0% (95% confidence interval 28.5% to 52.4%; 28/70), specificity of 99.9% (99.8% to 99.99%; 5431/5434), positive predictive value of 90.3% (74.2% to 98.0%; 28/31), and negative predictive value of 99.2% (99.0% to 99.4%; 5431/5473). When the void samples were assumed to be negative, a sensitivity was observed for LFT of 37.8% (26.8% to 49.9%; 28/74), specificity of 99.6% (99.4% to 99.8%; 5431/5452), positive predictive value of 84.8% (68.1% to 94.9%; 28/33), and negative predictive value of 93.4% (92.7% to 94.0%; 5431/5814). The sensitivity in participants with an RT-qPCR cycle threshold (Ct) of <18.3 (approximate viral loads >10 6 RNA copies/mL) was 90.9% (58.7% to 99.8%; 10/11), a Ct of <24.4 (>10 4 RNA copies/mL) was 69.4% (51.9% to 83.7%; 25/36), and a Ct of >24.4 (<10 4 RNA copies/mL) was 9.7% (1.9% to 23.7%; 3/34). LFT is likely to detect at least three fifths and at most 998 in every 1000 people with a positive RT-qPCR test result with high viral load. Conclusions The Innova LFT can be useful for identifying infections among adults who report no symptoms of covid-19, particularly those with high viral load who are more likely to infect others. The number of asymptomatic adults with lower Ct (indicating higher viral load) missed by LFT, although small, should be considered when using single LFT in high consequence settings. Clear and accurate communication with the public about how to interpret test results is important, given the chance of missing some cases, even at high viral loads. Further research is needed to understand how infectiousness is reflected in the viral antigen shedding detected by LFT versus the viral loads approximated by RT-qPCR.


2020 ◽  
Vol 3 (2) ◽  
pp. 73-76
Author(s):  
Kripa Dongol ◽  
Yogesh Neupane ◽  
Dipesh Shakya

Otolaryngologists are at high risk of acquiring coronavirus because most of the procedures are aerosol generating and we have to deal with upper airways which contain high viral load. The objective of this study is to elaborate the draping technique which diminishes aerosol in the operating room. Use of a framework and a drape with customized hand insertion ports help to contain the aerosol generated during the operative procedure. The draping technique acts as an additional form of protection from aerosol along with an increase in self-confidence to the healthcare workers during this pandemic.


PLoS ONE ◽  
2015 ◽  
Vol 10 (9) ◽  
pp. e0138546 ◽  
Author(s):  
Cristina Cheroni ◽  
Lorena Donnici ◽  
Alessio Aghemo ◽  
Francesca Balistreri ◽  
Annalisa Bianco ◽  
...  

2014 ◽  
Vol 9 (1) ◽  
Author(s):  
Ichiro Murakami ◽  
Michiko Matsushita ◽  
Takeshi Iwasaki ◽  
Satoshi Kuwamoto ◽  
Masako Kato ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document