Surface Modification and Ablation of Insulators Using a Tunable, Picosecond Mid-Infrared Laser

1998 ◽  
Vol 526 ◽  
Author(s):  
R. F. Haglund ◽  
D. R. Ermer ◽  
A. H. Lines ◽  
M. R. Papantonakis ◽  
H. K. Park ◽  
...  

AbstractUltrashort-pulse lasers with fundamental wavelengths ranging from near-infrared to near-ultraviolet are increasingly being used for laser-induced surface modification of non-metallic solids. The relaxation of the initial electronic excitation into vibrational relaxation modes can produce efficient ablation and other desirable surface modifications with little collateral damage because the laser energy is deposited on a time scale much shorter than thermal diffusion times. Little is known, however, about how ultrashort pulses interact with insulators at wavelengths in the vibrational infrared. This paper describes surface modifications achieved by picosecond laser irradiation in the 2-10 lim range. The laser source was a tunable, free-electron laser (FEL) with I-ps micro-pulses spaced 350 ps apart in a macropulse lasting up to 4 μs, with an average power of up to 3 W. This unusual pulse structure makes possible novel tests of the influences vs fluence and intensity, as well as the effects of resonant vibrational excitation. As model materials systems, we studied calcium carbonate, its isoelectronic cousin sodium nitrate, and fused silica. Particularly intriguing are surface modifications achieved by tuning the laser into vibrational resonances and overtones of the target materials, or by tailoring the energy content of the pulse. The mechanisms underlying these effects, and their implications for materials-modification strategies, are discussed.

2015 ◽  
Vol 23 (7) ◽  
pp. 8901 ◽  
Author(s):  
Umit Demirbas ◽  
Ilyes Baali ◽  
Durmus Alp Emre Acar ◽  
Alfred Leitenstorfer

1993 ◽  
Vol 47 (6) ◽  
pp. 812-815 ◽  
Author(s):  
Chris W. Brown ◽  
Su-Chin Lo

Optical-fiber measurements coupled with near-infrared spectra in the range of 5500 to 10,000 cm−1 are used to determine the optimum spectral region for remotely monitoring the energy content of natural gas at above ambient pressures. The system was configured with a Fourier transform near-infrared spectrometer and a fused-silica fiber bundle. The total energy values at a pressure of 100 psi were determined by the partial least-squares (PLS) calibration algorithm. The precision and accuracy for predicting the BTU content of an industry standard gas sample were less than 0.4% in the lower-frequency region of 5700 to 6400 cm−1.


2018 ◽  
Author(s):  
Chun Haur Khoo

Abstract Driven by the cost reduction and miniaturization, Wafer Level Chip Scale Packaging (WLCSP) has experienced significant growth mainly driven by mobile consumer products. Depending on the customers or manufacturing needs, the bare silicon backside of the WLCSP may be covered with a backside laminate layer. In the failure analysis lab, in order to perform the die level backside fault isolation technique using Photon Emission Microscope (PEM) or Laser Signal Injection Microscope (LSIM), the backside laminate layer needs to be removed. Most of the time, this is done using the mechanical polishing method. This paper outlines the backside laminate removal method of WLCSP using a near infrared (NIR) laser that produces laser energy in the 1,064 nm range. This method significantly reduces the sample preparation time and also reduces the risk of mechanical damage as there is no application of mechanical force. This is an effective method for WLCSP mounted on a PCB board.


Author(s):  
Alexander Richards ◽  
Matthew Weschler ◽  
Michael Durller

Abstract To help solve the navigational problem, i.e., being able to successfully locate a circuit for probing or editing without destroying chip functionality, a near-infrared (NIR), near-ultraviolet (NUV), and visible spectrum camera system was developed that attaches to most focused ion beam (FIB) or scanning electron microscope vacuum chambers. This paper reviews the details of the design and implementation of the NIR/NUV camera system, as instantiated upon the FEI FIB 200, with a particular focus on its use for the visualization of buried structures, and also for non-destructive real time area of interest location and end point detection. It specifically considers the use of the micro-optical camera system for its benefit in assisting with frontside and backside circuit edit, as well as other typical FIB milling activities. The quality of the image obtained by the IR camera rivals or exceeds traditional optical based imaging microscopy techniques.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xiaomei Yao ◽  
Xutao Zhang ◽  
Tingting Kang ◽  
Zhiyong Song ◽  
Qiang Sun ◽  
...  

AbstractA simple fabrication of end-bonded contacts InAsSb NW (nanowire) array detector to weak light is demonstrated in this study. The detector is fabricated using InAsSb NW array grown by molecular beam epitaxy on GaAs substrate. The metal-induced gap states are induced by the end-bonded contact which suppresses the dark current at various temperatures. The existence of the interface dipole due to the interfacial gap states enhances the light excitation around the local field and thus upgrades the photoresponsivity and photodetectivity to the weak light. The light intensity of the infrared light source in this report is 14 nW/cm2 which is about 3 to 4 orders of magnitude less than the laser source. The responsivity of the detector has reached 28.57 A/W at room temperature with the light (945 nm) radiation, while the detectivity is 4.81 × 1011 cm·Hz1/2 W−1. Anomalous temperature-dependent performance emerges at the variable temperature experiments, and we discussed the detailed mechanism behind the nonlinear relationship between the photoresponse of the device and temperatures. Besides, the optoelectronic characteristics of the detector clarified that the light-trapping effect and photogating effect of the NWs can enhance the photoresponse to the weak light across ultraviolet to near-infrared. These results highlight the feasibility of the InAsSb NW array detector to the infrared weak light without a cooling system.


1990 ◽  
Vol 68 (7) ◽  
pp. 1196-1200 ◽  
Author(s):  
Steven M. Barnett ◽  
François Dicaire ◽  
Ashraf A. Ismail

The study of colored organometallic complexes by dispersive Raman spectroscopy has been limited due to fluorescence or photodecomposition caused by the visible laser used as the excitation source. As a solution to this problem, FT-Raman spectroscopy with a near-infrared laser source has been useful in lowering fluorescence or photolysis in these samples. To investigate the utility of this technique, we have obtained and assigned the FT-Raman spectra of a series of arene chromium tricarbonyl complexes and of cyclopentadienyl manganese tricarbonyl. Some bands previously unobserved by dispersive Raman spectroscopy were seen, including a band assigned to a 13CO satellite in the spectrum of methylbenzoate chromium tricarbonyl. In addition, FT-Raman data for bovine serum albumin (BSA) and Protein-A are presented. Keywords: FT-Raman spectroscopy, metal carbonyl, proteins, organometallics, near infrared.


2012 ◽  
Vol 1 (4) ◽  
Author(s):  
Nelson Marquina ◽  
Roger Dumoulin-White ◽  
Arkady Mandel ◽  
Lothar Lilge

AbstractA randomized placebo-controlled clinical trial to evaluate an adjunctive treatment modality for pain associated with knee disorders was conducted utilizing a therapeutic laser system (low energy, non-surgical).The therapeutic laser system utilized a dual wavelength, multiple diode laser cluster probe with five super-pulsed 905 nm near-infrared (NIR) laser diodes, each emitting at 40 mW average power and four continuous wave 660 nm visible (VIS) red laser diodes, each emitting at 25 mW. It was used as an adjunctive modality providing 12 treatments, three times a week to a homogeneous patient population (n=126), in combination with standardized chiropractic techniques, to evaluate effectiveness on subjects presenting with osteoarthritis and knee pain. The primary endpoint was measured by the visual analog scale (VAS) to assess pain levels on a scale of 0–10. The success criteria for an individual patient in this study were identified as an improvement of 30% or more in the VAS from baseline to 12th treatment and/or an improvement of 20% or more in the VAS from baseline to 30-day follow-up evaluation.The data obtained in the study demonstrated that the present therapeutic laser system provided significant pain relief and osteoarthritic improvements in all primary evaluation criteria, with a statistical and clinical significance of


2017 ◽  
Author(s):  
K. Max Zhang ◽  
Bo Yang ◽  
Geng Chen ◽  
Jiajun Gu ◽  
James Schwab ◽  
...  

Abstract. DC, also referred to as Delta-C, measures enhanced light absorption of particulate matter (PM) samples at the near-ultraviolet (UV) range relative to the near-infrared range, which has been proposed previously as a woodsmoke marker due to the presence of enhanced UV light absorbing materials from wood combustion. In this paper, we further evaluated the applications and limitations of using DC as both a qualitative and semi-quantitative woodsmoke marker via joint continuous measurements of PM2.5 (by nephelometer pDR-1500) and light-absorptive PM (by 2-wavelength and 7-wavelength Aethalometer®) in three Northeastern U.S. cities/towns including Rutland, VT, Saranac Lake, NY and Ithaca, NY. We compared the pDR-1500 against a FEM PM2.5 sampler (BAM 1020), and identified a close agreement between the two instruments in a woodsmoke-dominated ambient environment. The analysis of seasonal and diurnal trends of DC, BC (880 nm) and PM2.5 concentrations supports the use of DC as an adequate qualitative marker. The strong linear relationships between PM2.5 and DC in both woodsmoke-dominated ambient and plume environments suggest that DC can reasonably serve as a semi-quantitative woodsmoke marker. We proposed a DC-based indicator for woodsmoke emission, which was then shown to exhibit relatively strong linear relationship with heating demand. While we observed reproducible PM2.5-DC relationships in similar woodsmoke-dominated ambient environments, those relationships differ significantly with different environments, and among individual woodsmoke sources. DC correlated much more closely with PM2.5 than EcoChem PAS2000-reported PAH in woodsmoke-dominated ambient environments. Our analysis also indicates the potential for PM2.5-DC relationships to be utilized to distinguish different combustion and operating conditions of woodsmoke sources, and that DC-Heating demand relationships could be adopted to estimate woodsmoke emissions. However, future studies are needed to elucidate those relationships.


2006 ◽  
Vol 29 (1) ◽  
pp. 14-24 ◽  
Author(s):  
Julien Courtois ◽  
Michal Szumski ◽  
Emil Byström ◽  
Agnieszka Iwasiewicz ◽  
Andrei Shchukarev ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document